174 research outputs found

    Improvement of radiopurity level of enriched 116^{116}CdWO4_4 and ZnWO4_4 crystal scintillators by recrystallization

    Get PDF
    As low as possible radioactive contamination of a detector plays a crucial role to improve sensitivity of a double beta decay experiment. The radioactive contamination of a sample of 116^{116}CdWO4_4 crystal scintillator by thorium was reduced by a factor ≈10\approx 10, down to the level 0.01 mBq/kg (228^{228}Th), by exploiting the recrystallization procedure. The total alpha activity of uranium and thorium daughters was reduced by a factor ≈3\approx 3, down to 1.6 mBq/kg. No change in the specific activity (the total α\alpha activity and 228^{228}Th) was observed in a sample of ZnWO4_4 crystal produced by recrystallization after removing ≈0.4\approx 0.4 mm surface layer of the crystal.Comment: 14 pages, 5 figures and 2 table

    First test of an enriched 116^{116}CdWO4_4 scintillating bolometer for neutrinoless double-beta-decay searches

    Full text link
    For the first time, a cadmium tungstate crystal scintillator enriched in 116^{116}Cd has been succesfully tested as a scintillating bolometer. The measurement was performed above ground at a temperature of 18 mK. The crystal mass was 34.5 g and the enrichment level ~82 %. Despite a substantial pile-up effect due to above-ground operation, the detector demonstrated a high energy resolution (2-7 keV FWHM in 0.2-2.6 MeV γ\gamma energy range), a powerful particle identification capability and a high level of internal radiopurity. These results prove that cadmium tungstate is an extremely promising detector material for a next-generation neutrinoless double-beta decay bolometric experiment, like that proposed in the CUPID project (CUORE Upgrade with Particle IDentification)

    Radioactive contamination of ZnWO4 crystal scintillators

    Full text link
    The radioactive contamination of ZnWO4 crystal scintillators has been measured deep underground at the Gran Sasso National Laboratory (LNGS) of the INFN in Italy with a total exposure 3197 kg x h. Monte Carlo simulation, time-amplitude and pulse-shape analyses of the data have been applied to estimate the radioactive contamination of the ZnWO4 samples. One of the ZnWO4 crystals has also been tested by ultra-low background gamma spectrometry. The radioactive contaminations of the ZnWO4 samples do not exceed 0.002 -- 0.8 mBq/kg (depending on the radionuclide), the total alpha activity is in the range: 0.2 - 2 mBq/kg. Particular radioactivity, beta active 65Zn and alpha active 180W, has been detected. The effect of the re-crystallization on the radiopurity of the ZnWO4 crystal has been studied. The radioactive contamination of samples of the ceramic details of the set-ups used in the crystals growth has been checked by low background gamma spectrometry. A project scheme on further improvement of the radiopurity level of the ZnWO4 crystal scintillators is briefly addressed.Comment: 15 pages, 8 figures, 6 tables, submitted for publicatio

    Study of Envelope Velocity Evolution of Type Ib-c Core-Collapse Supernovae from Observations of XRF 080109 / SN 2008D and GRB 060218 / SN 2006aj with BTA

    Full text link
    Results of modeling the spectra of two supernovae SN 2008D and SN 2006aj related to the X-ray flash XRF 080109 and gamma-ray burst GRB / XRF 060218, respectively, are studied. The spectra were obtained with the 6-meter BTA telescope of the Special Astrophysical Observatory of the Russian Academy of Sciences in 6.48 and 27.61 days after the explosion of SN 2008D, and in 2.55 and 3.55 days after the explosion of SN 2006aj. The spectra were interpreted in the Sobolev approximation with the SYNOW code. An assumption about the presence of envelopes around the progenitor stars is confirmed by an agreement between the velocities of lines interpreted as hydrogen and helium, and the empiric power-law velocity drop with time for the envelopes of classic core-collapse supernovae. Detection of a P Cyg profile of the H-beta line in the spectra of optical afterglows of GRBs can be a determinative argument in favor of this hypothesis.Comment: 12 pages, 6 figures, accepted for publication in Astrophysical Bulletin

    Proceedings of the third French-Ukrainian workshop on the instrumentation developments for HEP

    Full text link
    The reports collected in these proceedings have been presented in the third French-Ukrainian workshop on the instrumentation developments for high-energy physics held at LAL, Orsay on October 15-16. The workshop was conducted in the scope of the IDEATE International Associated Laboratory (LIA). Joint developments between French and Ukrainian laboratories and universities as well as new proposals have been discussed. The main topics of the papers presented in the Proceedings are developments for accelerator and beam monitoring, detector developments, joint developments for large-scale high-energy and astroparticle physics projects, medical applications.Comment: 3rd French-Ukrainian workshop on the instrumentation developments for High Energy Physics, October 15-16, 2015, LAL, Orsay, France, 94 page
    • …
    corecore