16 research outputs found

    Acu-TENS and Postexercise Expiratory Flow Volume in Healthy Subjects

    Get PDF
    Transcutaneous Electrical Nerve Stimulation over acupoints (Acu-TENS) facilitates recovery of resting heart rate after treadmill exercise in healthy subjects. Its effect on postexercise respiratory indices has not been reported. This study investigates the effect of Acu-TENS on forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) in healthy subjects after a submaximal exercise. Eleven male subjects were invited to the laboratory twice, two weeks apart, to receive in random order either Acu-TENS or Placebo-TENS (no electrical output from the TENS unit) over bilateral Lieque (LU7) and Dingchuan (EX-B1) for 45 minutes, before undergoing exercise following the Bruce protocol. Exercise duration, rate of perceived exertion (RPE), and peak heart rate (PHR) were recorded. Between-group FEV1 and FVC, before, immediately after, at 15, 30, and 45minutes postexercise, were compared. While no between-group differences in PHR, RPE, and FVC were found, Acu-TENS was associated with a longer exercise duration (0.9 min (P = .026)) and a higher percentage increase in FEV1 at 15 and 45 minutes postexercise (3.3 ± 3.7% (P = .013) and 5.1 ± 7.5% (P = .047), resp.) compared to Placebo-TENS. We concluded that Acu-TENS was associated with a higher postexercise FEV1 and a prolongation of submaximal exercise

    Acu-TENS Reduces Breathlessness during Exercise in People with Chronic Obstructive Pulmonary Disease

    Get PDF
    Background. Exertional dyspnoea limits level of physical activity in people with Chronic Obstructive Pulmonary Disease (COPD). This randomized, double-blinded, crossover study evaluated the effect of Acu-TENS, application of Transcutaneous Electrical Nerve Stimulation on acupoints, on breathlessness during exercise in people with COPD. Methods. Twenty-one participants, mean% predicted FEV1  50±21%, attended assessment followed by two intervention days, one week apart. On each intervention day, participants performed two endurance shuttle walk tests (ESWT) (Walk 1 and Walk 2). Walk 1 was performed without intervention and Walk 2 was performed with either Acu-TENS or Sham-TENS, in random order, for 45 minutes before and during Walk 2. Duration of each ESWT and dyspnoea score at isotime of Walk 1 and Walk 2 on each intervention day were compared. Between-group differences in ESWT duration and isotime dyspnoea were also compared. Results. At isotime of Walk 1 and Walk 2, Acu-TENS showed significant reduction in dyspnoea of −0.8 point (95% CI −0.2 to −1.4) but not in Sham-TENS [0.1 point (95% CI −0.4 to 0.6)]. Compared to Sham-TENS, Acu-TENS showed significant reduction in dyspnoea of −0.9 point (95% CI −0.2 to −1.6) while no between-group significance was found in ESWT duration. Conclusion. Acu-TENS alleviated dyspnoea during walking in people with COPD but did not increase walking duration

    Semiconductor Spintronics

    Full text link
    Spintronics refers commonly to phenomena in which the spin of electrons in a solid state environment plays the determining role. In a more narrow sense spintronics is an emerging research field of electronics: spintronics devices are based on a spin control of electronics, or on an electrical and optical control of spin or magnetism. This review presents selected themes of semiconductor spintronics, introducing important concepts in spin transport, spin injection, Silsbee-Johnson spin-charge coupling, and spindependent tunneling, as well as spin relaxation and spin dynamics. The most fundamental spin-dependent nteraction in nonmagnetic semiconductors is spin-orbit coupling. Depending on the crystal symmetries of the material, as well as on the structural properties of semiconductor based heterostructures, the spin-orbit coupling takes on different functional forms, giving a nice playground of effective spin-orbit Hamiltonians. The effective Hamiltonians for the most relevant classes of materials and heterostructures are derived here from realistic electronic band structure descriptions. Most semiconductor device systems are still theoretical concepts, waiting for experimental demonstrations. A review of selected proposed, and a few demonstrated devices is presented, with detailed description of two important classes: magnetic resonant tunnel structures and bipolar magnetic diodes and transistors. In most cases the presentation is of tutorial style, introducing the essential theoretical formalism at an accessible level, with case-study-like illustrations of actual experimental results, as well as with brief reviews of relevant recent achievements in the field.Comment: tutorial review; 342 pages, 132 figure

    Acceptance of the 'Assessment of Physiotherapy Practice (Chinese)' as a standardised evaluation of professional competency in Chinese physiotherapy students : An observational study

    Get PDF
    Background Development of an entry-level physiotherapy curriculum in China currently follows the World Confederation for Physical Therapy (WCPT) guidelines, however there is no standard, validated, assessment tool for physiotherapy practice in use in China. This article reports the process of translation of the “Assessment of Physiotherapy Practice” (APP), a validated assessment instrument adopted by all universities in Australia and New Zealand, into Chinese (APP-Chinese) and its implementation by Chinese physiotherapy clinical educators (CEs) and students during clinical placements. Methods The process of forward and backward translation of the APP was undertaken by a team of academics from universities in Shanghai, Hong Kong, United States and Australia. An APP-Chinese version was produced and used for assessment of the clinical performance of 4th year students at a university in Shanghai. Feedback on the implementation of the APP-Chinese was solicited from students and CEs using the same two questionnaires employed to assess implementation of the original APP. Results All CEs agreed that the rules used to score the APP-Chinese were helpful in assessing student performance. Over 90% of the CEs considered the APP-Chinese was pragmatic for use in the clinical environment in China. All students agreed with the rating of their performance on the APP-Chinese marked by their educators, and that the performance indicators were useful in guiding their expected performance behaviour. Conclusion The APP-Chinese is the first standardised assessment tool for evaluation of clinical performance of physiotherapy students in China and was shown to be well accepted by both students and CEs in the clinical education unit and university involved in this study

    Impacts of Cigarette Smoke (CS) on Muscle Derangement in Rodents—A Systematic Review

    No full text
    Cigarette smoke (CS) is the major risk factor for chronic obstructive pulmonary disease (COPD) and can induce systemic manifestations, such as skeletal muscle derangement. However, inconsistent findings of muscle derangement were reported in previous studies. The aim of the present study was to consolidate the available evidence and assess the impact of CS on muscle derangement in rodents. A comprehensive literature search of five electronic databases identified ten articles for final analysis. Results showed that the diaphragm, rectus femoris, soleus, and gastrocnemius exhibited significant oxidative to glycolytic fiber conversions upon CS exposure. In contrast, the extensor digitorum longus (EDL), plantaris, and tibialis did not exhibit a similar fiber-type conversion after CS exposure. Hindlimb muscles, including the quadriceps, soleus, gastrocnemius, and EDL, showed significant reductions in the CSA of the muscle fibers in the CS group when compared to the control group. Changes in inflammatory cytokines, exercise capacity, and functional outcomes induced by CS have also been evaluated. CS could induce a shift from oxidative fibers to glycolytic fibers in high-oxidative muscles such as the diaphragm, rectus femoris, and soleus, and cause muscle atrophy, as reflected by a reduction in the CSA of hindlimb muscles such as the quadriceps, soleus, gastrocnemius, and EDL

    The acute effects of cigarette smoke exposure on muscle fiber type dynamics in rats.

    No full text
    Reduced exercise capacity is common in people with chronic obstructive pulmonary diseases (COPD) and chronic smokers and is suggested to be related to skeletal muscle dysfunction. Previous studies using human muscle biopsies have shown fiber-type shifting in chronic smokers particularly those with COPD. These results, however, are confounded with aging effects because people with COPD tend to be older. In the present study, we implemented an acute 7-day cigarette smoke-exposed model using Sprague-Dawley rats to evaluate early effects of cigarette smoking on soleus muscles. Rats (n = 5 per group) were randomly assigned to either a sham air (SA) or cigarette smoking (CS) groups of three different concentrations of total particulate matters (TPM) (CSTPM2.5, CSTPM5, CSTPM10). Significantly lower percentages of type I and higher type IIa fiber were detected in the soleus muscle in CS groups when compared with SA group. Of these, only CSTMP10 group exhibited significantly lower citrate synthase activity and higher muscle tumor necrosis factor-α level than that of SA group. Tumor necrosis factor-α level was correlated with the percentage of type I and IIa fibers. However, no significant between-group differences were found in fiber cross-sectional area, physical activities, or lung function assessments. In conclusion, acute smoking may directly trigger the onset of glycolytic fiber type shift in skeletal muscle independent of aging

    Refining and adapting the measurement properties of evidence-based practice measures for physiotherapy students.

    No full text
    ObjectiveThere is a lack of reliable and valid evidence-based practice (EBP) measures for physiotherapy students. This study validated EBP-student (EBP-S) measures for physiotherapy students.MethodsEBP measures developed from previous research were cross-culturally validated for use by physiotherapy students. The adapted EBP-S consisted of six measures: use of EBP, EBP activities, EBP knowledge, self-efficacy for EBP, attitudes towards EBP, and perceptions of the teaching and assessment of EBP in the curriculum. The final version was completed by physiotherapy students (n = 335). The psychometric properties for each EBP-S measure were estimated, including construct validity using Rasch model, internal consistency reliability using person separation index (PSI), test-retest reliability using intraclass correlation coefficient (ICC), and differential item functioning (DIF).ResultsTwo formative measures (use of EBP and EBP activities) were only linguistically modified for use with students. A Rasch model was applied to the other four reflective measures. For knowledge, 55% (6/11) items fit the Rasch model with chi-square fit statistic (χ2) = 34.46, p = 0.08; PSI = 0.85. For self-efficacy, 89% (8/9) items fit the Rasch model with χ2 = 25.11, p = 0.80; PSI = 0.89. For attitudes, 62% (8/13) items fit the Rasch model with χ2 = 61.49, p = 0.00; PSI = 0.71. For perception of the teaching and assessment of EBP in the curriculum, 62% (8/13) items fit the Rasch model with χ2 = 80.99, p = 0.45; PSI = 0.92. perception of the teaching and assessment of EBP in the curriculum showed DIF in three items. The ICCs ranged between 0.80 and 0.98.ConclusionsThe EBP-S measures were validated for physiotherapy students, including the testing of psychometric properties, which were not tested in the original studies. Further refinements should be considered for the use of the EBP-S with other groups of students or if changes are applied to the current curriculum
    corecore