3 research outputs found

    A prospective, multi-centric, observational registry to evaluate performance of Excelℱ DES in ‘Real World, All Comers’ patient population

    Get PDF
    AbstractObjectivesThis study aims to assess the safety and efficacy of a biodegradable polymer-coated Rapamycin-Eluting Stent (Excel) used in conjunction with six-month dual antiplatelet therapy in daily practice.BackgroundThe polymeric material of cardiac stents has been reported to adversely affect the safety profile of the drug-eluting stents and is also suspected to cause serious long-term complications. It has been proposed that the biodegradable polymer coatings may reduce such late-stage adverse effects.MethodsThis is a prospective, multi-center registry of 654 patients from across 9 cardiology centers in India, who were enrolled and exclusively treated with Excel stents between February 2008 and May 2010. The recommended antiplatelet regimen included clopidogrel and aspirin for 6 months period, followed by lifelong aspirin therapy.ResultsThe study population included 46.94% diabetics, 24.31% smokers, 48.93% hypertensives and 14.98% hyperlipidemics. The cumulative rates of major adverse cardiac events were 0.153% at discharge and 1.38% at 12 months. The mean percentage of stenosis was 88.24 ± 9.17% No events occurred between 6 and 12 months.ConclusionsThis multi-center registry study on “real world, all comers” has, thus, showed that EXCELℱ stent which is PLA-coated biodegradable Rapamycin-Eluting Stent exhibited high efficacy and safety profile in treatment of patients undergoing PCI as evidenced by significantly lower rates of MACE and no case of stent thrombosis. There was no event even after DAPT was discontinued after 6 months

    The Paclitaxel-eluting PTCA-balloon in combination with a cobalt-chromium stent in two different sequences to treat de novo coronary artery lesions: An angiographic follow up study

    Get PDF
    Introduction: The paclitaxel-coated balloon catheter (DCB) based on the PACCOCATHÂź technology has yielded angiographic and clinical results superior to drug-eluting stents (DES) in situations like in-stent restenosis (ISR) and a trend towards superior results in small coronary vessels and side branches of coronary bifurcations. Using the DCB followed by cobalt–chromium stent (CoCr) deployment or with a reverse sequence may yield different outcomes in terms of late loss. Methods: 97 patients with de-novo coronary stenosis (55.6 ± 10.7 years, 79.4% male, ≄70%, length: ≀25 mm, vessel diameter: 2.5–4.0 mm) were randomly treated with the DCB (3 Όg/mmÂČ) followed by a CoCr-stent or stent first and DCB later. Six-month angiographic and one-year clinical follow-up intention-to-treat analyses were performed. Results: Angiographic and demographic baseline data was comparable between the two groups. When comparing balloon first versus stent first technique, the primary outcome variables were not statistically different for mean in-segment (0.51 ± 0.56 mm vs. 0.36 ± 0.55 mm, p = 0.23) and in-stent (0.52 ± 0.55 mm vs. 0.46 ± 0.52 mm, p = 0.65) late lumen loss. The lesion related 12-month MACE rates were 5/49 (10.2%) and 2/48 (4.2%) (p = 0.44). Lesion related thrombotic events occurred in three patients in balloon first and in one patient in stent first group, two of which were associated with early discontinuation of continuous dual anti-platelet therapy, two with suboptimal PCI, and one each were performed in a thrombotic lesion and a bifurcation type 1.1.0. Conclusion: Drug-coated balloon first followed by cobalt chromium stent deployment versus a reverse sequence is not associated with statistically significantly different 6-month angiographic or 12-month clinical outcomes
    corecore