30 research outputs found

    Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV

    Full text link
    An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be ±\pm5%, compared with the previous estimation of ±\pm15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.Comment: 13 pages, 7 figure

    Precise Measurement of Cosmic-Ray Proton and Helium Spectra with the BESS Spectrometer

    Get PDF
    We report cosmic-ray proton and helium spectra in energy ranges of 1 to 120 GeV and 1 to 54 GeV/nucleon, respectively, measured by a balloon flight of the BESS spectrometer in 1998. The magnetic-rigidity of the cosmic-rays was reliably determined by highly precise measurement of the circular track in a uniform solenoidal magnetic field of 1 Tesla. Those spectra were determined within overall uncertainties of +-5 % for protons and +- 10 % for helium nuclei including statistical and systematic errors.Comment: 12 pages, 4 figure

    Measurements of Cosmic-ray Low-energy Antiproton and Proton Spectra in a Transient Period of the Solar Field Reversal

    Get PDF
    The energy spectra of cosmic-ray low-energy antiprotons and protons have been measured by BESS in 1999 and 2000, during a period covering the solar magnetic field reversal. Based on these measurements, a sudden increase of the antiproton to proton flux ratio following the solar magnetic field reversal was observed, and it generally agrees with a drift model of the solar modulation.Comment: 4 pages, 4 figures, revised version accepted for publication in Phys. Rev. Let

    The diagnostic performance of a novel ELISA for human CTP (Cochlin-tomoprotein) to detect perilymph leakage.

    No full text
    Perilymphatic fistula is defined as an abnormal communication between the perilymph-filled space and the middle ear, or cranial spaces. The manifestations include a broad spectrum of neuro-otological symptoms such as hearing loss, vertigo/dizziness, disequilibrium, aural fullness, tinnitus, and cognitive dysfunction. By sealing the fistula, perilymphatic fistula is a surgically correctable disease. Also, appropriate recognition and treatment of perilymphatic fistula can improve a patient's condition and hence the quality of life. However, the difficulty in making a definitive diagnosis due to the lack of an appropriate biomarker to detect perilymph leakage has caused a long-standing debate regarding its management. We have reported a clinical test for the diagnosis of perilymphatic fistula by detecting a perilymph specific protein, Cochlin-tomoprotein, as a diagnostic marker using a western blot. The aim of this study is to establish an ELISA-based human Cochlin-tomoprotein detection test and to evaluate its diagnostic accuracy in clinical subjects. The results of ELISA showed good dilution reproducibility. The mean concentration was 49.7±9.4 of 10 perilymph samples. The ROC curve in differentiating the perilymph leakage condition from the normal middle ear was significant (P < 0.001) with an area under the curve (AUC) of 0.918 (95% CI 0.824-0.100). We defined the diagnostic criteria as follows: CTP<0.4 negative; 0.4≦CTP<0.8 intermediate; 0.8≦CTP(ng/ml) positive in the clinical usage of the hCTP ELISA, and sensitivity and specificity were 86.4% and 100%, respectively. We further tested the expression specificity of the Cochlin-tomoprotein by testing blood and CSF samples. The concentration was below the detection limit (0.2 ng/ml) in 38 of the 40 blood, and 14 of the 19 CSF samples. We report the accuracy of this test for the diagnosis of perilymphatic fistula. Using ELISA, we can improve the throughput of the test. Furthermore, it is useful for a large-scale study to characterize the clinical picture and delineate the management of this medical condition
    corecore