98 research outputs found

    アーノルド・ファイン作品集

    Get PDF
    Urinary type IV collagen (U-Col4) and albumin excretion is evaluated to monitor the development of diabetic kidney disease. However, U-Col4 excretion in the general population without diabetes has not yet been fully elucidated. In this study, 1067 participants without diabetes and with urinary albumin-creatinine ratio <300 mg/gCr (normo- or microalbuminuria) who underwent an annual health examination in 2004 were enrolled and observed for 5 years. They were divided according to the amount of U-Col4 or urinary albumin excreted. The decline in estimated glomerular filtration rate (eGFR) was calculated. In participants with eGFR ≥80 mL/min, abnormal U-Col4 excretion was indicated as a significant independent risk factor for 10% eGFR change per year, which is one of the prognostic factors for the development of end-stage kidney disease. Moreover, in contrast to urinary albumin excretion, U-Col4 excretion was not related to age or kidney function, suggesting that some individuals with abnormal U-Col4 excretion can have an independent hidden risk for the development of kidney dysfunction. In conclusion, it is important to measure U-Col4 excretion in the general population without diabetes to determine changes in renal features in every individual and help detect future complications such as diabetic kidney disease. If U-Col4 excretion is abnormal, kidney manifestation should be carefully followed up, even if the kidney function and urinalysis findings are normal

    Surrogate marker of schistocytes

    Get PDF
    Objectives : Hematopoietic stem cell transplantation (HSCT)-associated thrombotic microangiopathy (TA-TMA) is an important early post-treatment condition. This study evaluated the Revised %MICRO, a parameter obtained from the ADVIA 2120i automated blood cell counter, as a surrogate marker of the schistocyte ratio. We hypothesized that individual differences between the %MICRO value and schistocyte ratio would remain constant. Design and Methods: EDTA-2K-treated peripheral blood samples were collected from 19 patients who underwent allogeneic HSCT from April 2014 to September 2018. First, the baseline difference, X, was calculated using a sample from the first day after HSCT as X = %MICRO (first day) – schistocyte ratio (first day). Next, the Revised %MICRO for each subsequent day was calculated as Revised %MICRO = %MICRO – X. We evaluated correlations of the schistocyte ratio with the calculated %MICRO and Revised %MICRO and the RBC fragment, RBC distribution width, %MICRO and Revised %MICRO data obtained from the ADVIA 2120i. Results : The mean schistocyte percentage and Revised %MICRO were both 0.4% ± 0.6. RBC fragments correlated weakly with the %MICRO and schistocyte ratio, respectively (r = 0.162 and r = 0.771, respectively), whereas the Revised %MICRO correlated strongly with the schistocyte ratio (r = 0.893). Conclusion : The Revised %MICRO appears to be a good surrogate of the schistocyte ratio in a clinical setting

    IVC diameter in patients undergoing HD

    Get PDF
    Background : IVC diameter on expiration (IVCdexp) is measured by echocardiography routinely. It is used to estimate volume status and designated as a definitive marker for determining dry weight (DW) in patients undergoing hemodialysis (HD). Methods : A cross-sectional study. Outpatients (n = 107), and inpatients (n = 35) undergoing HD were enrolled. IVCdexp was measured on non-dialysis days in outpatients and dialysis days before and after the dialysis session in inpatients. In outpatients, the relationship of IVCdexp with echocardiography findings and clinical characteristics was analyzed. IVCdexp was compared with the other DW markers as a predictive factor for intradialytic hypotension. In inpatients, IVCdexp was analyzed by dividing inpatients with or without fluid in extravascular space. Results : IVCdexp ranged from 5.4 to 16.9 mm in outpatients who had optimal DW. IVCdexp could reflect on volume status, but not predictive for intradialytic hypotension and not suggestive of fluid in extravascular space. Conclusions : IVCdexp was a rough marker to estimate volume status and only useful in suggesting apparent hypervolemia or hypovolemia. We should know that the IVCdexp value is affected by a lot of factors and not a definitive marker for estimating practical DW

    Successful treatment of highly advanced immunoglobulin G4-related kidney disease presenting renal mass-like regions with end-stage kidney failure : a case study

    Get PDF
    Background: Immunoglobulin G4-related kidney disease characterized by immunoglobulin G4-positive plasma cell-rich tubulointerstitial nephritis has distinctive serological and radiological findings. Renal prognosis is good because of a good response to glucocorticoids. Here we report a case of successful treatment of highly advanced immunoglobulin G4-related kidney disease presenting renal mass-like regions with end-stage kidney failure. Case Presentation: A 59-year-old Japanese man was referred to our hospital because of uremia with a creatinine level of 12.36 mg/dL. Urinalysis revealed mild proteinuria and hyperβ2microglobulinuria, and blood tests showed hyperglobulinemia with an IgG level of 3243 mg/dL and an IgG4 level of 621 mg/dL. Non-contrast computed tomography revealed renal mass-like regions. Based on the findings, immunoglobulin G4-related kidney disease was suspected, however, further radiological examination showed unexpected results. Ga-67 scintigraphy showed no kidney uptake. T2-weighted magnetic resonance imaging revealed high-intensity signals which corresponded to mass-like regions and multiple patchy low-intensity signals in kidney cortex. Finally, the patient was diagnosed with immunoglobulin G4-related kidney disease by renal pathology of severe immunoglobulin G4-positive plasma cellrich tubulointerstitial nephritis and characteristic fibrosis. He received 50 mg oral prednisolone, which was tapered with a subsequent decrease of serum creatinine and IgG4 levels. One year after initiation of treatment, he achieved normalization of serum IgG4 level and proteinuria, and remained off dialysis with a creatinine level of 3.50 mg/dL. After treatment with steroids, repeat imaging suggested bilateral severe focal atrophy. However, mass-like regions did not show atrophic change although renal atrophy was evident in patchy low-intensity lesions on T2-weighted magnetic resonance imaging. These findings suggest that multiple patchy low-intensity signals and high-intensity mass-like regions were mildly atrophic lesions of immunoglobulin G4-related kidney disease due to severe fibrosis and normal parts of kidney, respectively. Conclusions: In immunoglobulin G4-related kidney disease with severe kidney failure, radiological findings should be carefully examined. In addition, renal prognosis may be good despite highly advanced tubulointerstitial nephritis and fibrosis

    1-year tolvaptan efficacy in ADPKD

    Get PDF
    Autosomal dominant polycystic kidney disease (ADPKD) develops into end-stage kidney disease by 65 years of age in an estimated 45%-70% of patients. Recent trials revealed that tolvaptan inhibits disease progression both in early-stage or late-stage ADPKD ; however, stratified analysis showed a difference of favorable factors correlated with tolvaptan efficacy between early-stage and late-stage ADPKD. Thus, we examined the efficacy of tolvaptan in ADPKD with a wide range of estimated glomerular filtration rates (eGFR). We enrolled 24 patients with eGFR 35.3 (28.0-65.5) ml / min / 1.73m2 and evaluated treatment effect as ΔΔeGFR (ml / min / 1.73m2 / year) or ΔΔtotal kidney volume (TKV) (% / year) that was calculated as post-treatment annual change - pre-treatment annual change. Pre ΔeGFR was significantly low in eGFR responders, defined as ΔΔeGFR > 0 ml / min / 1.73m2 / year. In eGFR responders, pre ΔeGFR, post ΔeGFR, eGFR, TKV, and proteinuria were significantly correlated with ΔΔeGFR. In TKV responders defined as ΔΔTKV > 5 % / year, we identified hypertension history, proteinuria, TKV, and post ΔTKV as significantly correlated factors with ΔΔTKV. In conclusion, pre ΔeGFR may be a predictive factor of therapeutic efficacy on kidney function. Tolvaptan may have greater efficacy in early-stage ADPKD with rapid GFR decline or with well-controlled blood pressure

    Urinary type IV collagen excretion in the Japanese general population without diabetes

    Get PDF
    Urinary type IV collagen (U-Col4) and albumin excretion is evaluated to monitor the development of diabetic kidney disease. However, U-Col4 excretion in the general population without diabetes has not yet been fully elucidated. In this study, 1067 participants without diabetes and with urinary albumin-creatinine ratio <300 mg/gCr (normo- or microalbuminuria) who underwent an annual health examination in 2004 were enrolled and observed for 5 years. They were divided according to the amount of U-Col4 or urinary albumin excreted. The decline in estimated glomerular filtration rate (eGFR) was calculated. In participants with eGFR ≥80 mL/min, abnormal U-Col4 excretion was indicated as a significant independent risk factor for 10% eGFR change per year, which is one of the prognostic factors for the development of end-stage kidney disease. Moreover, in contrast to urinary albumin excretion, U-Col4 excretion was not related to age or kidney function, suggesting that some individuals with abnormal U-Col4 excretion can have an independent hidden risk for the development of kidney dysfunction. In conclusion, it is important to measure U-Col4 excretion in the general population without diabetes to determine changes in renal features in every individual and help detect future complications such as diabetic kidney disease. If U-Col4 excretion is abnormal, kidney manifestation should be carefully followed up, even if the kidney function and urinalysis findings are normal

    Assay for Glycosaminoglycans by Tandem Mass Spectrometry and its Applications

    Get PDF
    Glycosaminoglycans (GAGs) are distributed in the whole body and play a variety of important physiological roles associated with inflammation, growth, coagulation, fibrinolysis, lipolysis, and cell-matrix biology. Accumulation of undegraded GAGs in lysosomes gives rise to a distinct clinical syndrome, mucopolysaccharidoses. Measurement of each specific GAG in a variety of specimens is urgently required to understand GAG interaction with other molecules, physiological status of patients, and prognosis and pathogenesis of the disease. We established a highly sensitive and accurate tandem mass spectrometry (LC-MS/MS) method for measurements of disaccharides derived from four specific GAGs [dermatan sulfate (DS), heparan sulfate (HS), keratan sulfate (KS), and chondroitin sulfate (CS)]. Disaccharides were produced by specific enzyme digestion of each GAG, and quantified by negative ion mode of multiple reaction monitoring. Subclasses of HS and GAGs with identical molecular weights can be separated using a Hypercarbcolumn (2.0 mm×50 mm, 5 μm) with an aectonitrile gradient in ammonium acetate (pH 11.0). We also developed a GAG assay by RapidFire with tandem mass spectrometry (RF-MS/MS). The RF system consists of an integrated solid phase extraction robot that binds and de-salts samples from assay plates and directly injects them into a MS/MS detector, reducing sample processing time to ten seconds. RF-MS/MS consequently yields much faster throughput than conventional LC-MS/MS-based methods. However, the RF system does not have a chromatographic step, and therefore, cannot distinguish GAGs that have identical molecular weights. Both methods can be applied to analysis of dried blood spots, blood, and urine specimens. In this article, we compare the assay methods for GAGs and describe their potential applications

    Importance of pre pump arterial pres sure monitoring in hemodialysis patients

    Get PDF
    Pre-pump arterial pressure (PreAP) is monitored to avoid generating excessive negative pressure. National Kidney Foundation K/DOQI clinical practice guidelines for vascular access recommend that PreAP should not fall below-250 mmHg because excessive negative PreAP can lead to a decrease in the delivery of blood flow, inadequate dialysis, and hemolysis. Nonetheless, these recommendations are consistently disregarded in clinical practice and pressure sensors are often removed from the dialysis circuit.Thus far,delivered blood flow has been reported to decrease at values more negative than -150 mmHg of PreAP. These values have been analyzed by an ultrasonic flowmeter and not directly measured. Furthermore, no known group has evaluated whether PreAP-induced hemolysis occurs at a particular threshold. Therefore, the aim of this study was to clarify the importance of PreAP in the prediction of inadequate dialysis and hemolysis. By using different diameter needles, human blood samples from healthy volunteers were circulated in a closed dialysis circuit. The relationship between PreAP and delivered blood flow or PreAP and hemolysis was investigated. We also investigated the optimal value for PreAP using several empirical monitoring methods, such as a pressure pillow. Our investigation indicated that PreAP is a critical factor in the determination of delivered blood flow and hemolysis,both of which occured at pressure values more negative than -150 mmHg. With the exception of direct pressure monitoring, commonly used monitoring methods for PreAP were determined to be ineffective. We propose that the use of a vacuum monitor would permit regular measurement of PreAP
    corecore