6 research outputs found
Extraperitoneal urine leak after renal transplantation: the role of radionuclide imaging and the value of accompanying SPECT/CT - a case report
<p>Abstract</p> <p>Background</p> <p>The differentiation of the nature of a fluid collection as a complication of kidney transplantation is important for management and treatment planning. Early and delayed radionuclide renography can play an important role in the evaluation of a urine leak. However, it is sometimes limited in the evaluation of the exact location and extent of a urine leak.</p> <p>Case Presentation</p> <p>A 71-year-old male who had sudden anuria, scrotal swelling and elevated creatinine level after cadaveric renal transplantation performed Tc-99 m MAG3 renography to evaluate the renal function, followed by an ultrasound which was unremarkable. An extensive urine leak was evident on the planar images. However, an exact location of the urine leak was unknown. Accompanying SPECT/CT images confirmed a urine leak extending from the lower aspect of the transplant kidney to the floor of the pelvic cavity, presacral region and the scrotum via right inguinal canal as well as to the right abdominal wall.</p> <p>Conclusions</p> <p>Renal scintigraphy is very useful to detect a urine leak after renal transplantation. However, planar imaging is sometimes limited in evaluating the anatomical location and extent of a urine leak accurately. In that case accompanying SPECT/CT images are very helpful and valuable to evaluate the anatomical relationships exactly.</p
Recommended from our members
Value of Precise Localization of Recurrent Multiple Myeloma With F-18 FDG PET/CT
A 37-year-old man with multiple myeloma in remission underwent routine fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) study for disease restaging. Both FDG-PET and CT images showed focal abnormalities in the region of the T6 vertebra, but the fused images that are routinely provided with PET/CT could precisely localize the FDG active lesion to a soft tissue focus in the epidural space, away from a lytic nonactive vertebral body lesion despite their close proximity. The PET/CT scan identified a few other metabolically active osseous lesions out of many lytic bony changes throughout the skeleton. Accordingly, the patient received the correct management for an impending spinal cord compression at the appropriate time, in addition to systemic therapy for disease relapse
Recommended from our members
PET/CT image fusion error due to urinary bladder filling changes: consequence and correction
A considerable change of urinary bladder (UB) shape in PET compared with CT in integrated PET/CT system is frequently noted. This study initially evaluated this finding with and without oral contrast (OC) use. In addition, a one bed pelvic section (PLV) repeat acquisition was investigated as a solution to this problem.
(18)FDG PET/CTs of 88 patients were analyzed. OC was administered in 68 patients, of whom 31 had PLV images taken 5-10 min later. Three-dimensional mid-UB CT and PET matching measurements were compared. In addition, UB walls displacement between CT and PET were analyzed.
The mean UB height was significantly increased (P < 0.001) in PET when compared with CT, both anteriorly and posteriorly; however, UB width and depth were not significantly different. An upward shift of superior UB wall in PET from equivalent CT images was noted, whereas there was no appreciable displacement of the other UB walls. The percent UB height increase on PET from CT was significantly greater with than without OC use. The UB height difference between PET and CT was markedly reduced on PLV when compared with the original scans.
Caution should be exerted during the interpretation of PET/CT scans of the pelvis as there is significant upward expansion of UB on PET compared with CT that appears to be exaggerated by OC use, likely due to additional fluid load. The PET/CT fusion errors of UB can be substantially resolved through a separate PLV acquisition presumably due to the shorter time interval of UB scan completion between CT and PET
Usefulness of 123I-MIBG Scintigraphy in the Evaluation of Patients with Known or Suspected Primary or Metastatic Pheochromocytoma or Paraganglioma: Results from a Prospective Multicenter Trial
Although
123
I-MIBG has been in clinical use for the imaging of pheochromocytoma for many years, a large multicenter evaluation of this agent has never been performed. The present study was designed to provide a prospective confirmation of the performance of
123
I-MIBG scintigraphy for the evaluation of patients with known or suspected primary or metastatic pheochromocytoma or paraganglioma