4 research outputs found

    Structural, dielectric and magnetic properties of nickel substituted cobalt ferrite nanoparticles: Effect of nickel concentration

    No full text
    Nickel substituted cobalt ferrite nanoparticles with composition Co1−xNixFe2O4 (0.0 ≤ x ≤ 1.0) was synthesized using simple, low temperature auto combustion method. The X-ray diffraction patterns reveal the formation of cubic phase spinel structure. The crystallite size varies from 30-44 nm with the nickel content. Porous and agglomerated morphology of the bulk sample was displayed in the scanning electron microscopy. Micro Raman spectroscopy reveals continuous shift of Eg and Eg(2) stokes line up to 0.8 Ni substitution. The dispersion behavior of the dielectric constant with frequency and the semicircle nature of the impedance spectra show the cobalt nickel ferrite to have high resistance. The ferromagnetic nature is observed in all the samples, however, the maximum saturation magnetization was achieved by the 0.4 Ni substituted cobalt ferrite, which is up to the 92.87 emu/gm at 30K

    A novel approach in the use of radiofrequency catheter ablation of septal hypertrophy in hypertrophic obstructive cardiomyopathy

    Get PDF
    Objective: Alcohol septal ablation (ASA) is a therapeutic alternative to surgical myectomy in patients with hypertrophic obstructive cardiomyopathy (HOCM). However, the anatomical variability of the septal branch, risk of complete heart block, and late onset ventricular arrhythmias are limitations to its therapeutic usage. There is recent interest in the use of radiofrequency catheter ablation (RFCA) as a therapeutic option in HOCM. We aimed to assess the safety and efficacy of RFCA in the treatment of symptomatic HOCM. Methods: Seven patients with symptomatic HOCM (mean age 43.7 ± 15.6 years, five males), and significant left ventricular outflow tract (LVOT) gradient despite optimal drug therapy, underwent ablation of the hypertrophied interventricular septum. These patients had unfavorable anatomy for ASA. Ablation was performed under 3D electro-anatomical system guidance using an open irrigated tip catheter. The region of maximal LV septal bulge as seen on intracardiac echocardiography was targeted. Patients were followed up at 1, 6, and 12 months post-procedure. Results: The mean baseline LVOT gradient by Doppler echocardiography was 81 ± 14.8 mm of Hg which reduced to 48.5 ± 22.6 (p = 0.0004), 49.8 ± 19.3 (p = 0.0004), and 42.8 ± 26.1 mm of Hg (p = 0.05) at 1, 6, and 12 months respectively. Symptoms improved at least by one NYHA class in all but one patient. One patient developed transient pulmonary edema post-RFA. There were no other complications. Conclusion: RFCA of the hypertrophied septum causes sustained reduction in the LVOT gradient and symptomatic improvement among patients with HOCM. Electroanatomical mapping helps to perform the procedure safely

    Worldwide survey on implantation of and outcomes for conduction system pacing with His bundle and left bundle branch area pacing leads.

    No full text
    BACKGROUND Adoption and outcomes for conduction system pacing (CSP), which includes His bundle pacing (HBP) or left bundle branch area pacing (LBBAP), in real-world settings are incompletely understood. We sought to describe real-world adoption of CSP lead implantation and subsequent outcomes. METHODS We performed an online cross-sectional survey on the implantation and outcomes associated with CSP, between November 15, 2020, and February 15, 2021. We described survey responses and reported HBP and LBBAP outcomes for bradycardia pacing and cardiac resynchronization CRT indications, separately. RESULTS The analysis cohort included 140 institutions, located on 5 continents, who contributed data to the worldwide survey on CSP. Of these, 127 institutions (90.7%) reported experience implanting CSP leads. CSP and overall device implantation volumes were reported by 84 institutions. In 2019, the median proportion of device implants with CSP, HBP, and/or LBBAP leads attempted were 4.4% (interquartile range [IQR], 1.9-12.5%; range, 0.4-100%), 3.3% (IQR, 1.3-7.1%; range, 0.2-87.0%), and 2.5% (IQR, 0.5-24.0%; range, 0.1-55.6%), respectively. For bradycardia pacing indications, HBP leads, as compared to LBBAP leads, had higher reported implant threshold (median [IQR]: 1.5 V [1.3-2.0 V] vs 0.8 V [0.6-1.0 V], p = 0.0008) and lower ventricular sensing (median [IQR]: 4.0 mV [3.0-5.0 mV] vs. 10.0 mV [7.0-12.0 mV], p < 0.0001). CONCLUSION In conclusion, CSP lead implantation has been broadly adopted but has yet to become the default approach at most surveyed institutions. As the indications and data for CSP continue to evolve, strategies to educate and promote CSP lead implantation at institutions without CSP lead implantation experience would be necessary

    Worldwide survey on implantation of and outcomes for conduction system pacing with His bundle and left bundle branch area pacing leads

    No full text
    corecore