17 research outputs found

    Teste de receptores de estrógeno e progesterona em carcinoma de mama: concordância dos resultados entre laboratórios locais e de referência no Brasil

    Get PDF
    CONTEXT AND OBJECTIVE: Breast cancer accounts for approximately one quarter of all cancers in females. Estrogen and progesterone receptor testing has become an essential part of the clinical evaluation of breast carcinoma patients, and accurate results are critical in identifying patients who may benefit from hormone therapy. The present study had the aim of investigating the concordance of the results from hormone receptor tests between a reference laboratory and local (or community) laboratories in Brazil. DESIGN AND SETTING: Retrospective study at a reference pathology laboratory. METHODS: The concordance in the results from hormone receptor tests between a reference laboratory and 146 local laboratories in Brazil was compared in relation to 500 invasive breast carcinoma cases, using immunohistochemistry. RESULTS: There was concordance in 89.4% (447/500 cases) and 85.0% (425/500 cases) of the results from estrogen (&#954; = 0.744, P < 0.001) and progesterone (&#954; = 0.688, P < 0.001) receptor tests, respectively, between local and reference laboratories. This was similar to findings in other countries. The false negative rates from estrogen and progesterone receptor tests in local laboratories were 8.7% and 14.4%, respectively. The false positive rates from estrogen and progesterone receptor tests in local laboratories were 15.5% and 16.0%, respectively. CONCLUSION: Technical and result interpretation issues may explain most of the discordances in hormone receptor testing in local laboratories. Validation of estrogen and progesterone receptor tests at local laboratories, with rigorous quality control measures, is strongly recommended in order to avoid erroneous treatment of breast cancer patients.CONTEXTO E OBJETIVO: O carcinoma de mama é responsável por cerca de um quarto de todos os cânceres em mulheres. O teste de receptores de estrógeno e progesterona se tornou parte essencial da avaliação clínica de pacientes com carcinoma de mama; assim, resultados precisos são fundamentais para identificação de pacientes que podem se beneficiar da terapia hormonal. O presente estudo tem por objetivo investigar a concordância nos resultados do teste de receptores hormonais entre um laboratório referência e laboratórios locais (ou comunitários) do Brasil. TIPO DE ESTUDO E LOCAL: Estudo retrospectivo em laboratório referência em patologia no Brasil. MÉTODOS: A concordância nos resultados dos testes de receptores hormonais entre um laboratório referência e 146 diferentes laboratórios locais brasileiros foi comparada em 500 casos de carcinoma invasivo de mama através da imunoistoquímica. RESULTADOS: Houve concordância de 89,4% (447/500 casos) e 85,0% (425/500 casos) nos resultados dos testes de receptores de estrógeno (&#954; = 0,744, P < 0,001) e progesterona (&#954; = 0,688, P < 0,001), respectivamente, entre laboratórios locais e referência, similar à descrita em outros países. A taxa de resultados falso-negativos nos testes de receptores de estrógeno e progesterona em laboratórios locais foi de 8,7% e 14,4%, respectivamente. A taxa de resultados falso-positivos nos testes de receptores de estrógeno e progesterona em laboratórios locais foi de 15,5% e 16,0%, respectivamente. CONCLUSÃO: Questões técnicas e de interpretação dos resultados podem explicar a maior parte das discordâncias nos testes de receptores hormonais em laboratórios locais. A validação dos testes de receptores de estrógeno e progesterona pelos laboratórios locais com medidas de controle de qualidade rigorosas é fortemente recomendada de modo a evitar o tratamento errôneo de pacientes com carcinoma de mama

    Comparison of results of prognostic and predictive markers (HER2 and estrogen and progesterone receptors) for breast carcinoma between local and reference laboratories in Brazil

    No full text
    O câncer de mama corresponde a aproximadamente um quarto das neoplasias malignas em mulheres. A incidência do câncer de mama no Brasil é de cerca de 50.000 novos casos por ano, sendo considerado importante problema de saúde pública. HER2 e receptores hormonais (receptores de estrógeno e progesterona) são considerados os mais importantes marcadores prognósticos e preditivos em carcinoma de mama. A amplificação do gene HER2 ou a superexpressão da proteína HER2, que ocorre em cerca de 20 porcento dos carcinomas de mama, está associada a curso clínico mais agressivo e determina elegibilidade para terapia específica anti-HER2 com trastuzumabe. A terapia hormonal reduz em mais de 50 porcento o risco relativo de recorrência da doença em pacientes com tumores sensíveis a esse tratamento. Os testes de HER2 e receptores hormonais são partes essenciais da avaliação clínica das pacientes com carcinoma de mama; resultados precisos são fundamentais na identificação de pacientes que podem ser beneficiadas por terapias específicas. O presente estudo investigou a concordância nos resultados dos testes de HER2 e receptores hormonais determinados por imuno-histoquímica em 500 carcinomas invasivos de mama entre um laboratório referência e laboratórios locais de todas as regiões geográficas do Brasil. Os resultados demonstram baixa concordância geral (171/500 casos, 34,2 porcento) em relação aos resultados do teste de HER2 entre laboratórios locais e referência, o que pode estar relacionado ao baixo volume de testes de HER2 realizados, inexperiência com o sistema de escores de HER2 e/ou questões técnicas relacionadas à imuno-histoquímica nos laboratórios locais. A concordância nos resultados do teste de receptores de estrógeno e progesterona foi de 89,4 porcento (447/500 casos) e de 85,0 porcento (425/500 casos), respectivamente, entre laboratórios locais e referência. Padronização dos testes de HER2 e receptores hormonais com medidas de controle de qualidade rigorosas por laboratórios locais é fortemente recomendada para se evitar o tratamento inadequado de pacientes com câncer de mamaBreast cancer accounts for approximately one quarter of all cancers in females. The incidence of breast cancer in Brazil is about 50,000 new cases per year, and it is considered an important public health problem. HER2 and hormone receptors (estrogen and progesterone receptors) are considered the main prognostic and predictive markers for breast carcinoma. HER2 gene amplification or HER2 protein overexpression, detected in about 20 percent of breast carcinomas, predicts a more aggressive clinical course and determines eligibility for targeted therapy with trastuzumab. Hormonal therapy reduces the relative risk of recurrence by more than 50% in breast cancer patients with hormone-sensitive tumors. HER2 and hormone receptors testing has become an essential part of the clinical evaluation of all breast carcinoma patients, and accurate results are critical in identifying patients who may benefit from targeted therapy. The present study investigated the concordance in the results of HER2 and hormone receptors immunohistochemistry assays performed in 500 invasive breast carcinomas between a reference laboratory and local laboratories from all geographic regions of Brazil. Our results showed an overall poor concordance (171/500 cases, 34.2 percent) regarding HER2 results between local and reference laboratories, which may be related to the low-volume load of HER2 assays, inexperience with HER2 scoring system, and/or technical issues related to immunohistochemistry in local laboratories. The concordance of estrogen and progesterone receptors results was 89.4 percent (447/500 cases) and 85.0 percent (425/500 cases), respectively, between local and reference laboratories. Standardization of HER2 and hormone receptors testing with rigorous quality control measures by local laboratories is highly recommended in order to avoid erroneous treatment of breast cancer patient

    Silicone-Induced Granuloma of Breast Implant Capsule (SIGBIC): Histopathology and Radiological Correlation

    No full text
    Currently, attention has been given to complications related to breast implants, especially due to the presence of anaplastic large cell lymphoma (ALCL) related to silicone implants. Many manuscripts attempt to associate silicone presence with clinical complaints reported by patients, while others try to demonstrate the mechanisms of silicone bleeding by permeability loss of breast implant surfaces. There also are reports of foreign body type reactions from implant fibrous capsule to silicone corpuscles. However, there seems to be no study that correlates the clinical, radiological, and histological correlations of these lesions. The objective of this review is to correlate radiological findings of silicone-induced granuloma of breast implant capsule (SIGBIC) from breast MRI (BMRI) scans and complementary findings of ultrasound (US) and positron emission tomography (PET) scan, and its histology originated from surgical breast implant capsulectomy. To make this correlation possible, we divided SIGBIC into three radiological findings: (1) intracapsular SIGBIC, (2) SIGBIC with extracapsular extension, and (3) mixed SIGBIC associated with seroma. Our experience demonstrates histological-radiological correlation in SIGBIC diagnosis. Knowledge of these findings may demonstrate its real importance in terms of public health and patient management. We believe that SIGBIC is currently underdiagnosed by lack of training, guidance, and management in our clinical practice

    Silicone-Induced Granuloma of Breast Implant Capsule (SIGBIC): Histopathology and Radiological Correlation

    No full text
    Currently, attention has been given to complications related to breast implants, especially due to the presence of anaplastic large cell lymphoma (ALCL) related to silicone implants. Many manuscripts attempt to associate silicone presence with clinical complaints reported by patients, while others try to demonstrate the mechanisms of silicone bleeding by permeability loss of breast implant surfaces. There also are reports of foreign body type reactions from implant fibrous capsule to silicone corpuscles. However, there seems to be no study that correlates the clinical, radiological, and histological correlations of these lesions. The objective of this review is to correlate radiological findings of silicone-induced granuloma of breast implant capsule (SIGBIC) from breast MRI (BMRI) scans and complementary findings of ultrasound (US) and positron emission tomography (PET) scan, and its histology originated from surgical breast implant capsulectomy. To make this correlation possible, we divided SIGBIC into three radiological findings: (1) intracapsular SIGBIC, (2) SIGBIC with extracapsular extension, and (3) mixed SIGBIC associated with seroma. Our experience demonstrates histological-radiological correlation in SIGBIC diagnosis. Knowledge of these findings may demonstrate its real importance in terms of public health and patient management. We believe that SIGBIC is currently underdiagnosed by lack of training, guidance, and management in our clinical practice

    Implantes de polietileno gel e poroso em cavidade anoftálmica de coelhos

    No full text
    OBJETIVO: Comparar implantes de polietileno poroso no estado sólido e gel em cavidades enucleadas. MÉTODOS: Trinta e seis coelhos albinos foram submetidos à enucleação do olho direito, recebendo esferas de polietileno poroso (18 animais) ou gel (18 animais), de 12 mm de diâmetro. Os animais foram avaliados semanalmente por exame clínico e mensalmente por ultra-sonografia modo B, realizada 30, 60 e 90 dias após a cirurgia, tendo sido os animais sacrificados aos 90 dias. Após o sacrifício, o conteúdo orbitário foi removido e examinado histologicamente. RESULTADOS: Cinco animais (27,2%) que receberam os implantes de polietileno poroso tiveram extrusão do implante. Houve extrusão em 94,4% dos animais que receberam a esfera de polietileno gel, tendo-se observado que o diâmetro das esferas gel extruídas encontrava-se aumentado em relação ao diâmetro da esfera implantada. A ultra-sonografia mostrou que o implante de polietileno poroso se vascularizou e que o gel não, o que foi confirmado pelo exame histológico. CONCLUSÃO: Esferas de polietileno no estado gel sofrem hidratação e aumentam de volume, sendo necessário conhecer o seu tamanho final antes da implantação. A ultra-sonografia permite conhecer a vascularização do implante, podendo ser usada na avaliação da integração esfera-hospedeiro.PURPOSE: To evaluate porous polyethylene implants as compared to solid and gel spheres in anophthalmic cavities. METHODS: Thirty-six white rabbits underwent a right eye enucleation with placement of 12 mm of porous (18 animals) or gel (18 animals) polyethylene spheres. The animals were submitted to weekly clinical evaluation. Ultrasound examinations were done 30, 60 and 90 days after surgery and the animals were sacrificed on the day 90th. Then, the orbit content was removed and submitted to light microscopy. RESULTS: Five animals (27.2%) which received porous polyethylene spheres presented sphere extrusion. With the gel polyethylene spheres, the extrusions happened in 94.4% of the animals and it was observed that the expelled gel spheres had higher diameter then the implanted ones. Ultrasound evaluation showed that the porous polyethylene implant becomes vascularized but the gel not, as confirmed by histological examination. CONCLUSION: Spheres of material in the gel state hydrate and increase in volume making it necessary to know the final size before the implantation. Ultrasound examination allows the evaluation of the implant-tissue integration

    Uso de 2-octil-cianoacrilato na reconstrução da cavidade anoftálmica de coelhos

    No full text
    OBJETIVO: Avaliar a ligação entre músculos oculares extrínsecos e esferas de polietileno poroso usando um bioadesivo. MÉTODOS: Estudo experimental envolvendo 8 coelhos albinos submetidos a enucleação do olho direto com colocação de implante esférico de polietileno poroso de 12 mm de diâmetro unido aos músculos oculares extrínsecos por meio do bioadesivo 2-octil-cianoacrilato. Noventa dias após a cirurgia os animais foram sacrificados e o conteúdo orbitário removido. em 4 animais foi realizado estudo biomecânico, avaliando-se a força de ruptura entre a musculatura e a esfera (grupo implante) e entre a musculatura e a esclera nos olhos contralaterais (grupo controle). Nos outros 4 animais foi realizada análise histológica. RESULTADO: A avaliação biomecânica revelou que a força de ruptura entre esfera-músculo e esclera-músculo foram semelhantes quando se usa o adesivo de cianoacrilato. O exame histológico mostrou reação fibrovascular no local da adesão entre a musculatura e a esfera, sem efeitos deletérios aos tecidos. Ao redor dos implantes foi possível observar pseudocápsula e no interior, neovasos e tecido fibrovascular preenchendo os espaços entre os grânulos do polietileno. CONCLUSÃO: O adesivo 2-octil-cianoacrilato mantém boa força de adesão na união entre os músculos e as esferas de polietileno poroso, com redução do tempo cirúrgico e sem efeitos deletérios aos tecidos orbitais. Desta forma, deve-se considerar o uso do bioadesivo na reconstrução da cavidade anoftálmica.PURPOSE: To evaluate fixation by a bioadhesive of the external ocular muscles to the porous polyethylene spheres. METHODS: An experimental study was performed using eight white rabbits that underwent right eye enucleation with placement of 12 mm spheres of porous polyethylene. The rectus muscles (superior and inferior) were attached to the implant with a bioadhesive (2-octyl-cyanoacrylate) applied to the inferior side of the external muscles. Ninety days after surgery the orbital content was removed and 4 animals were submitted to a tensile strength test of the muscle-sphere attachment and the other 4 to histological evaluation. RESULTS: The tensile strength test showed that the rupture force was similar between the muscle and porous polyethylene sphere bond attachment and normal external ocular muscles. The histologic evaluation showed fibrous tissue reaction and muscle-sphere attachment with no deleterious effects to the tissues; a capsule formation around the spheres and new vessels inside the implant were also observed. CONCLUSION: 2-octyl-cyanoacrylate provides strength adhesion between muscles and spheres, with surgery time reduction and does not provoke deleterious effects on the orbital tissues. Thus, the bioadhesive might be a good choice for use in the anophthalmic cavity reconstruction

    Coristoma ósseo episcleral: relato de caso

    No full text
    Os autores apresentam um caso de coristoma ósseo episcleral (COE), cujo diagnóstico foi dado pelo exame histopatológico. O coristoma ósseo episcleral é tipo raro de coristoma, em geral localizado no quadrante temporal superior, sendo formado por tecido ósseo maduro.Episcleral osseous choristoma (COE) is a rare tumor, characterized by the presence of a plaque of mature bone in the episcleral tissues of the upper temporal quadrant. This is a case report of COE whose diagnosis was established after histological features
    corecore