6 research outputs found

    A novelty in laparoscopic total colectomy with natural orifice specimen extraction using a plastic cover

    No full text
    Introduction: Minimally invasive colectomy has been performed for some years for many patients worldwide without much complications compared to the open approach. In this study we explained our experience regarding a modification in laparoscopic total colectomy and removing the specimen with Natural Orifice Specimen Extraction (NOSE) through rectum using a plastic cover for the first time. Methods and material: This was an experimental study on a new technique of total colectomy with a small modification. Total colectomy was performed based on 7 port laparoscopic approach. Rectum was sparred. Colon was then taken out through the anal canal using a plastic cover. Results: Thirteen patients underwent laparoscopic total colectomy by removal of the specimen through rectum. Mean age of patients was 42.23 ± 8.15 years. Mean duration of operation was 130 ± 32.4 min. All patients had an uneventful postoperative hospitalization. Discussion: Laparoscopic total colectomy has been proven to have superior benefits than the open approach. In NOSE technique, colon is removed from the anal canal without any complication or consuming much time. This technique might have less pain and removes the complications associated with an incision on the skin to remove the specimen. Also, due to low price of a usual plastic cover, it can be used instead of other techniques to remove the specimen through the rectum. Resumo: Introdução: A colectomia minimamente invasiva vem sendo realizada há alguns anos em muitos pacientes no mundo inteiro, apresentando menos intercorrências do que a abordagem aberta. Neste estudo, os autores relatam sua experiência com uma modificação da colectomia total laparoscópica e extração de espécime em orifício natural (NOSE) pelo reto, usando uma cobertura plástica pela primeira vez. Métodos e materiais: Este foi um estudo experimental sobre uma nova técnica de colectomia total com uma pequena modificação. A colectomia total foi realizada com base na abordagem laparoscópica de sete portas. O reto foi poupado. O cólon foi então retirado pelo canal anal usando uma cobertura plástica. Resultados: Treze pacientes foram submetidos a colectomia total laparoscópica por remoção do espécime pelo reto. A idade média dos pacientes foi de 42,23 ± 8,15 anos. A duração média da operação foi de 130 ± 32,4 minutos. Para todos os pacientes, a internação pós-operatória transcorreu sem intercorrências. Discussão: Foi comprovado que a colectomia total laparoscópica apresenta benefícios superiores à abordagem aberta. Na técnica NOSE, o cólon é removido mais rapidamente do canal anal, sem nenhuma intercorrência. Essa técnica pode causar menos dor e remove as complicações associadas a uma incisão na pele para remover o espécime. Além disso, devido ao baixo preço de uma cobertura plástica comum, ela pode ser usada no lugar de outras técnicas para remover o espécime pelo reto

    Application of breast scintigraphy for patients with suspicious (breast imaging-reporting and data system IV) breast lesions

    No full text
    Background: The surgery for a breast imaging-reporting and data system (BIRADS) IV lesions needs imaging or pathology supporting data. The roll of breast scintigraphy for this purpose is unclear. Materials and Methods: In a prospective design, 16 patients with 25 BIRADS IV lesions who were scheduled for surgery were included. Before the surgery, breast scintigraphy was done using a nondedicated dual head gamma camera in the prone position employing a shaped foam pad providing imaging at breast pendulous position. Twenty mCi 99 mTc methoxy-isobutyl-isonitrile was injected and two 15 and 60-min delayed imaging were done (anterior, bilateral, and single photon emission computed tomography [SPECT] projections). Pathology reports were collected and tumor to nontumor uptake ratio (T/NT) was analyzed, accordingly. Results: Out of all lesions, 12 were malignant (invasive ductal and lobular carcinoma ductal carcinoma in situ). At 15 min, T/NT was insignificantly higher in the malignant compared to benign lesions (22.8 ± 23.9 vs. 10.1 ± 10.1; P = 0.109). The optimal T/NT cutoff for discrimination of malignant and benign lesions was 20. Only 1 out of 13 benign lesions presented uptake >20 (7.7%; false-positive rate; P = 0.047). The diagnostic accuracy, sensitivity, and specificity for T/NT calculated at 0.68, 0.42, and 0.92, respectively. The T/NT at 60 min remained unchanged for either benign or malignant lesions (22.3 ± 30.2 vs. 11.7 ± 17.1; P = 0.296). Conclusions: Breast scintigraphy with general purpose gamma camera employing SPECT imaging may assist the selection of BIRADS IV lesions in need for surgery. All uptake positive cases should undergo surgery and decision for uptake negative cases should be made based on other data

    Small interfering RNAs (siRNAs) in cancer therapy: a nano-based approach

    No full text
    Cancer is one of the most complex diseases that has resulted in multiple genetic disorders and cellular abnormalities. Globally, cancer is the most common health concern disease that is affecting human beings. Great efforts have been made over the past decades in biology with the aim of searching novel and more efficient tools in therapy. Thus, small interfering RNAs (siRNAs) have been considered one of the most noteworthy developments which are able to regulate gene expression following a process known as RNA interference (RNAi). RNAi is a post-transcriptional mechanism that involves the inhibition of gene expression through promoting cleavage on a specific area of a target messenger RNA (mRNA). This technology has shown promising therapeutic results for a good number of diseases, especially in cancer. However, siRNA therapeutics have to face important drawbacks in therapy including stability and successful siRNA delivery in vivo. In this regard, the development of effective siRNA delivery systems has helped addressing these issues by opening novel therapeutic windows which have allowed to build up important advances in Nanomedicine. In this review, we discuss the progress of siRNA therapy as well as its medical application via nanoparticle-mediated delivery for cancer treatment.Peer reviewe

    SARS-CoV-2 Omicron (B.1.1.529) Variant: A Challenge with COVID-19

    No full text
    Since the beginning of the coronavirus disease 2019 (COVID-19) pandemic, there have been multiple peaks of the SARS-CoV-2 (severe acute respiratory syndrome coronavirus virus 2) infection, mainly due to the emergence of new variants, each with a new set of mutations in the viral genome, which have led to changes in the pathogenicity, transmissibility, and morbidity. The Omicron variant is the most recent variant of concern (VOC) to emerge and was recognized by the World Health Organization (WHO) on 26 November 2021. The Omicron lineage is phylogenetically distinct from earlier variants, including the previously dominant Delta SARS-CoV-2 variant. The reverse transcription–polymerase chain reaction (RT–PCR) test, rapid antigen assays, and chest computed tomography (CT) scans can help diagnose the Omicron variant. Furthermore, many agents are expected to have therapeutic benefits for those infected with the Omicron variant, including TriSb92, molnupiravir, nirmatrelvir, and their combination, corticosteroids, and interleukin-6 (IL-6) receptor blockers. Despite being milder than previous variants, the Omicron variant threatens many lives, particularly among the unvaccinated, due to its higher transmissibility, pathogenicity, and infectivity. Mounting evidence has reported the most common clinical manifestations of the Omicron variant to be fever, runny nose, sore throat, severe headache, and fatigue. This review summarizes the essential features of the Omicron variant, including its history, genome, transmissibility, clinical manifestations, diagnosis, management, and the effectiveness of existing vaccines against this VOC

    Intraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study

    No full text
    Precise diagnosis of thyroid nodules is challenging due to non-diagnostic/inconclusive results and uncertainties about the malignancy of follicular neoplasms (FNs), even in frozen-section pathology. Therefore, surgical management, especially in Bethesda III and IV categories, may be complicated, and sometimes a second surgery may be required. The Thyroid Nodule Impedance Measurement System (TN-IMS) consists of a metallic patch attached to submental skin and a G20 I.V. cannula inserted into the targeted nodules. Two impedance-based parameters named Z1kHz and impedance phase slope (IPS) in 100 kHz to 500 kHz of the thyroid nodules are recorded and compared with their histopathological results as the gold standard. TN-IMS was intra-surgically applied to 103 human thyroid nodules and normal thyroid tissues. A remarkable consistency between defined co-ranges of Z1kHz/IPS and the histopathological status of specimens was achieved (p < 0.001). Based on these measurements, it was concluded that intraoperative bioelectrical impedance scanning of thyroid nodules would be a helpful complementary approach to detecting high-risk excision-required thyroid nodules
    corecore