1 research outputs found

    Quantitative Determination of Octylonium in Human Plasma by LC–MS

    No full text
    The purpose of this investigation was to develop a method for measuring the concentration of octylonium in human plasma. Hydrochloric acid was added to the plasma samples before pretreatment to improve the stability of the octylonium. After liquid–liquid extraction with ethylacetate and isopropanol (10:1), the analytes were separated by chromatography on a reversed-phase C18 column and detected by LC–MS–MS with electrospray ionization–ionization. The coefficient of variation for the precision of the assay was less than 10.1%, and the accuracy ranged from 98.0 to 106.5%. The limit of quantification or sensitivity was 0.2 ng mL−1. This method was validated by measuring octylonium in the plasma of healthy human subjects after administration of a single 120-mg oral dose of octylonium bromide. Thus, a highly sensitive and accurate analytical method was developed to determine the concentration of octylonium in human plasma. </p