4,311 research outputs found

    An artificial neural network approach for modelling the ward atmosphere in a medical unit

    Get PDF
    Artificial neural networks (ANNs) have been developed, implemented and tested on the basis of a four-year-long experimental data set, with the aim of analyzing the performance and clinical outcome of an existing medical ward, and predicting the effects that possible readjustments and/or interventions on the structure may produce on it. Advantages of the ANN technique over more traditional mathematical models are twofold: on one hand, this approach deals quite naturally with a large number of parameters/variables, and also allows to identify those variables which do not play a crucial role in the system dynamics; on the other hand, the implemented ANN can be more easily used by a staff of non-mathematicians in the unit, as an on-site predictive tool. As such, the ANN model is particularly suitable for the case study. The predictions from the ANN technique are then compared and contrasted with those obtained from a generalized kinetic approach previously proposed and tested by the authors. The comparison on the two case periods shows the ANN predictions to be somewhat closer to the experimental values. However, the mean deviations and the analysis of the statistical coefficients over a span of multiple years suggest the kinetic model to be more reliable in the long run, i.e., its predictions can be considered as acceptable even on periods that are quite far away from the two case periods over which the many parameters of the model had been optimized. The approach under study, referring to paradigms and methods of physical and mathematical models integrated with psychosocial sciences, has good chances of gaining the attention of the scientific community in both areas, and hence of eventually obtaining wider diffusion and generalization.

    Test results on the first 13 kA prototype HTS leads for the LHC

    Get PDF
    Prototypes of 13 kA HTS current leads for the Large Hadron Collider (LHC) have been specified by CERN and produced by several manufacturers. The specification defines the required thermo-electric performance and the geometric limitations imposed by the LHC infrastructure. A report is given of the results obtained from extensive tests on these leads. (7 refs)

    Tests Results on the First 13 kA Prototype HTS Leads for the LHC

    Get PDF
    Prototypes of 13 kA HTS current leads for the Large Hadron Collider (LHC) have been specified by CERN and produced by several manufacturers. The specification defines the required thermo-electric performance and the geometric limitations imposed by the LHC infrastructure. A report is given of the results obtained from extensive tests on these leads

    Measurements and calibration of the stripline BPM for the ELI-NP facility with the stretched wire method

    Get PDF
    A methodology has been developed to perform electrical characterization of the stripline BPMs for the future Gamma Beam System of ELI Nuclear Physics facility in Romania. Several prototype units are extensively benchmarked and the results are presented in this paper. The BPM sensitivity function is determined using a uniquely designed motorized test bench with a stretched wire to measure the BPM response map. Here, the BPM feedthroughs are connected to Libera Brilliance electronics and the wire is fed by continuous wave signal, while the two software-controlled motors provide horizontal and vertical motion of the BPM around the wire. The electrical offset is obtained using S-parameter measurements with a Network Analyzer (via the “Lambertson” method) and is referenced to the mechanical offse
    • …
    corecore