    Challenges and successes in the implementation of option B+ to prevent mother-to-child transmission of HIV in southern Swaziland.

    Get PDF
    BACKGROUND: Universal antiretroviral therapy (ART) for all pregnant/ breastfeeding women living with Human Immunodeficiency Virus (HIV), known as Prevention of mother-to child transmission of HIV (PMTCT) Option B+ (PMTCTB+), is being scaled up in most countries in Sub-Saharan Africa. In the transition to PMTCTB+, many countries face challenges with proper implementation of the HIV care cascade. We aimed to describe the feasibility of a PMTCTB+ approach in the public health sector in Swaziland. METHODS: Lifelong ART was offered to a cohort of HIV+ pregnant women aged ≥16 years at the first antenatal care (ANC1) visit in 9 public sector facilities, between 01/2013 and 06/2014. The study enrolment period was divided into 3 phases (early: 01-06/2013, mid: 07-12/2013 and late: 01-06/2014) to account for temporal trends. Kaplan-Meier estimates and Cox proportional-hazards regression models were applied for ART initiation and attrition analyses. RESULTS: Of 665 HIV+ pregnant women, 496 (74.6%) initiated ART. ART initiation increased in later study enrolment phases (mid: aHR: 1.41; later: aHR: 2.36), and decreased at CD4 ≥ 500 (aHR: 0.69). 52.9% were retained in care at 24 months. Attrition was associated with ANC1 in the third trimester (aHR: 2.37), attending a secondary care facility (aHR: 1.98) and ART initiation during later enrolment phases (mid aHR: 1.48; late aHR: 1.67). Of 373 women eligible, 67.3% received a first VL. 223/251 (88.8%) were virologically suppressed (< 1000 copies/mL). Of 670 infants, 53.6% received an EID test, 320/359 had a test result recorded and of whom 7 (2.2%) were HIV+. CONCLUSIONS: PMTCTB+ was found to be feasible in this setting, with high rates of maternal viral suppression and low transmission to the infant. High treatment attrition, poor follow-up of mother-baby pairs and under-utilisation of VL and EID testing are important programmatic challenges

    Field suitability and diagnostic accuracy of the Biocentric® open real-time PCR platform for plasma-based HIV viral load quantification in Swaziland

    No full text
    Abstract Background Viral load (VL) testing is being scaled up in resource-limited settings. However, not all commercially available VL testing methods have been evaluated under field conditions. This study is one of a few to evaluate the Biocentric platform for VL quantification in routine practice in Sub-Saharan Africa. Methods Venous blood specimens were obtained from patients eligible for VL testing at two health facilities in Swaziland from October 2016 to March 2017. Samples were centrifuged at two laboratories (LAB-1, LAB-2) to obtain paired plasma specimens for VL quantification with the national reference method and on the Biocentric platform. Agreement (correlation, Bland–Altman) and accuracy (sensitivity, specificity) indicators were calculated at the VL thresholds of 416 (2.62 log10) and 1000 (3.0 log10) copies/mL. Leftover samples from patients with discordant VL results were re-quantified and accuracy indicators recalculated. Logistic regression was used to compare laboratory performance. Results A total of 364 paired plasma samples (LAB-1: n = 198; LAB-2: n = 166) were successfully tested using both methods. The correlation was high (R = 0.82, p < 0.01), and the Bland–Altman analysis showed a minimal mean difference (− 0.03 log10 copies/mL; 95% CI: -1.15 to 1.08). At the clinical threshold level of 3.0 log10 copies/mL, the sensitivity was 88.6% (95% CI: 78.7 to 94.9) and the specificity was 98.3% (95% CI: 96.1 to 99.4). Sensitivity was higher in LAB-1 (100%; 95% CI: 71.5 to 100) than in LAB-2 (86.4%; 95% CI: 75.0 to 94.0). Most upward (n = 8, 2.2%) and downward (n = 11, 3.0%) misclassifications occurred at the 2.62 log threshold, with LAB-2 having a 16 (95% CI: 2.26 to 113.27; p = 0.006) times higher odds of downward misclassification. After retesting of discordant leftover samples (n = 17), overall sensitivity increased to 93.5% (95% CI: 85.5 to 97.9) and 97.1% (95% CI: 90.1 to 99.7) at the 2.62 and 3.0 thresholds, and specificity increased to 98.6% (95% CI: 96.5 to 99.6) and 99.0% (95% CI: 97.0 to 99.8) respectively. Conclusions The test characteristics of the Biocentric platform were overall comparable to the national reference method for VL quantification. One laboratory tended to misclassify VL results downwards, likely owing to unmet training needs and lack of previous hands-on practice
    corecore