495 research outputs found

    Impedance drop determines ablation lesion volume at the same level of ablation index

    Get PDF
    New parameters such as ablation index (AI) have been developed to create reliable ablation lesions. This study was performed to evaluate whether RF energy delivery with the same ablation index creates the similar ablation lesion volume. Ablation lesions were created in 5 pig hearts at ex-vivo state. Ablation was performed using an external-irrigation contact-force sensing catheter on the epicardial side of the left ventricle with 90-degree of angle. RF ablation time was adjusted for targeting AI 600 at 8 different conditions. Lesion volume created with 0–5g of contact force at 20 W was significantly lower than that of 11–20g at 40W despite of the same AI (125 ± 76.2 vs. 272 ± 49.5 mm3, P < 0.05). Quality of ablation lesion was variable in the condition of poor contact at low power for the ablation of ex-vivo swine left ventricle, and high-quality lesions could be expected when the impedance drop is satisfactory even though the same level of AI is applied during ablation

    Effect of the Ratio of Raw Material Components on the Physico-chemical Characteristics of Emulsion-type Pork Sausages

    Get PDF
    This study was conducted to investigate the effects of raw material ratio on the physicochemical characteristics of emulsion-type pork sausages. Experiment design was divided into 12 treatments, based on protein level (P), fat level (3P, 3.5P, and 4P), and water level (4P+10, 4P+15, 4P+20, and 4P+25). The pH and shear force values were significantly higher in T7 (3.5P fat and 4P+20 water) than those of other treatments. The lightness and redness were greatly reduced by increasing the quantity of water. The treatments containing 3P fat and 4P+20 water had the highest values of cohesiveness, springiness, gumminess, and chewiness. On the whole, when the protein (P) and fat (3P, 3.5P, 4P) levels were fixed, an increase over the appropriate moisture level deteriorated many physicochemical characteristics

    Analysis of Long-Range Transport of Carbon Dioxide and Its High Concentration Events over East Asian Region Using GOSAT Data and GEOS-Chem Modeling

    Get PDF
    This study aims to evaluate the long-range transport of CO2 in East Asian region, using concentration data in a surface measurement site (Gosan Station), column averaged concentration data of satellite-borne instrument (GOSAT), and GEOS-Chem modeling results for the period of June 2009 to May 2011. We perform a validation of the data from GOSAT and GEOS-Chem with total column observations (TCCON). The analysis of the long-range transport and high concentration (HC) events using surface/satellite observations and modeling results is conducted. During the HC events, the concentrations in CO2 and other air pollutants such as SO2 and CO are higher than that of all episodes. It means that CO2, known as a globally well-mixed gas, may also act as a fingerprint of human activity with unique regional characteristics like other air pollutants. This comprehensive analysis, in particular with GOSAT CO2 observation data, shows that CO2 plume with high concentration can be long-range transported with 1-2 days' duration with regional scale. We can find out with GEOS-Chem tagging simulation that more than 45% of the elevated CO2 concentration over central/eastern China, Korea, and Japan on high concentration days can be explained by emission sources of East Asia mainland.open0

    Efficacy and Safety of Human Placental Extract Solution on Fatigue: A Double-Blind, Randomized, Placebo-Controlled Study

    Get PDF
    Introduction. Fatigue is a common symptom, but only a few effective treatments are available. This study was conducted to assess the efficacy and safety of the human placental extract solution, which has been known to have a fatigue recovery effect. Methods. A total of 315 subjects were randomly assigned to three groups: group 1 (with Unicenta solution administration), group 2 (with exclusively human placental extract administration, excluding other ingredients from the Unicenta solution), and the placebo group. Subsequently, solutions were administered for four weeks. Results. The fatigue recovery rate was 71.00% in group 1, 71.72% in group 2, and 44.21% in the placebo group, which show statistically significant differences between the group 1 and the placebo group (P value = 0.0002), and between group 2 and the placebo group (P value = 0.0001). Conclusion. The human placental extract solution was effective in the improvement of fatigue

    Differentiation of the right versus left outflow tract ventricular arrhythmias using local activation time at the His bundle electrogram

    Get PDF
    Background Although multiple algorithms based on surface electrocardiographic criteria have been introduced to localize idiopathic ventricular arrhythmia (VA) origins from the outflow tract (OT), their diagnostic accuracy and clinical usefulness remain limited. We evaluated whether local activation time of the His bundle region could differentiate left and right ventricular OT VA origins in the early stage of electrophysiology study. Methods We studied 30 patients who underwent catheter ablation for OT VAs with a left bundle branch block pattern and inferior axis QRS morphology. The interval between the local V signal on the mapping catheter placed in the RVOT and His bundle region (V(RVOT)-V(HB) interval) and the interval from QRS complex onset to the local V signal on the His bundle region (QRS-V(HB) interval) were measured during VAs. Results The V(RVOT)-V(HB) and QRS-V(HB) intervals were significantly shorter in patients with LVOT VAs. The area under the curve (AUC) for the V(RVOT)-V(HB) interval by receiver operating characteristic analysis was 0.865. A cutoff value of ≤ 50 ms predicted an LVOT origin of VA with sensitivity, specificity, and positive and negative predictive values of 100%, 62.5%, 40%, and 100%, respectively. The QRS-V(HB) interval showed similar diagnostic accuracy (AUC, 0.840), and a cutoff value of ≤ 15 ms predicted an LVOT origin of VA with a sensitivity, specificity, and positive and negative predictive values of 100%, 70.8%, 45.2%, and 100%, respectively. Conclusion The V(RVOT)-V(HB) and QRS-V(HB) intervals could differentiate left from right OT origins of VA with high sensitivity and negative predictive values
    corecore