341 research outputs found

    Real-time data-driven and multi-scale model-guided system for bioproccess digital twin platform

    Get PDF
    Please click Additional Files below to see the full abstract

    Gene expression profiling of cancer stem cell in human lung adenocarcinoma A549 cells

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The studies on cancer-stem-cells (CSCs) have attracted so much attention in recent years as possible therapeutic implications. This study was carried out to investigate the gene expression profile of CSCs in human lung adenocarcinoma A549 cells.</p> <p>Results</p> <p>We isolated CSCs from A549 cell line of which side population (SP) phenotype revealed several stem cell properties. After staining the cell line with Hoechst 33342 dye, the SP and non-side population (non-SP) cells were sorted using flow cytometric analysis. The mRNA expression profiles were measured using an Affymetrix GeneChip<sup>® </sup>oligonucleotide array. Among the sixty one differentially expressed genes, the twelve genes inclusive three poor prognostic genes; Aldo-keto reductase family 1, member C1/C2 (AKR1C1/C2), Transmembrane 4 L six family member 1 nuclear receptor (TM4SF1), and Nuclear receptor subfamily 0, group B, member 1 (NR0B1) were significantly up-regulated in SP compared to non-SP cells.</p> <p>Conclusion</p> <p>This is the first report indicating the differences of gene expression pattern between SP and non-SP cells in A549 cells. We suggest that the up-regulations of the genes AKR1C1/C2, TM4SF1 and NR0B1 in SP of human adenocarcinoma A549 cells could be a target of poor prognosis in anti-cancer therapy.</p

    Functional and structural characteristics of anticancer peptide Pep27 analogues

    Get PDF
    BACKGROUND: A secreted peptide Pep27 initiates the cell death program in S. pneumoniae through signal transduction. This study was undertaken to evaluate the relation between the structure and cytotoxic activity of Pep27 and its analogues on cancer cells. RESULTS: Pep27anal2 characterized substituting ((2)R→W), ((4)E→W), ((11)S→W) and ((13)Q→W) in native Pep27, exhibited greater hydrophobicity and anticancer activity than Pep27 and other analogues. The IC(50 )values of Pep27anal2 were approximately 10 – 30 μM in a number of cell lines (AML-2, HL-60, Jurkat, MCF-7 and SNU-601). Confocal microscopy showed that Pep27anal2-FITC was localized in the plasma membrane, and then moving from the membrane to subcellular compartments with the initiation of membrane blebbing. Flow cytometric analysis using propidium iodide and Annexin V also revealed that Pep27anal2 induced apoptosis with minor membrane damage. Electron microscopy revealed that Pep27 induced apoptosis in Jurkat cells. The anticancer activity of Pep27anal2 was neither abrogated by pan-caspase inhibitor (Z-VAD-fmk) nor related to cytochrome c release from mitochondria. The 3D solution structures of these two Pep27 peptides revealed that both form a random coil conformation in water; however, they adopted stable α-helical conformations in solutions. CONCLUSION: The results indicate that Pep27anal2 can penetrate the plasma membrane, and then induce apoptosis in both caspase-and cytochrome c-independent manner. The hydrophobicity of Pep27anal2 appears to play an important role in membrane permeabilization and/or anticancer properties. The structure-functional relationships of these peptides are also discussed. It is proposed that Pep27anal2 is a potential candidate for anticancer therapeutic agents

    Six-Month Comparison of Coronary Endothelial Dysfunction Associated With Sirolimus-Eluting Stent Versus Paclitaxel-Eluting Stent

    Get PDF
    ObjectivesThis study was designed to investigate whether endothelial dysfunction is related to drug-eluting stent (DES) implantation at 6 months after stenting.BackgroundCurrent available DES could delay vessel healing and subsequently impair endothelial function.MethodsEndothelial function was estimated at 6-month follow-up in 75 patients (31 men, mean age 62.1 years) with a DES (39 sirolimus-eluting stents [SES], 36 paclitaxel-eluting stents [PES]), and 10 patients with a bare-metal stent (BMS) to the left anterior descending artery, by incremental acetylcholine (Ach) infusion (20 μg/min, 50 μg/min, 100 μg/min) and nitrate (200 μg/min) into the left coronary ostium. Vascular responses were quantitatively measured in arterial segments 5 mm proximal and distal to DES and compared with corresponding segments in the BMS group and midsegments in the left circumflex artery as a reference nonstented artery. All antianginal agents were withheld for at least 72 h before coronary angiography.ResultsGreater vasoconstriction to Ach was observed in both the SES and PES groups than in the BMS group or control segments of left circumflex artery. Vasoconstriction to Ach was more prominent in arterial segments distal to stents in both SES and PES groups compared with those in the BMS group (p &lt; 0.001). The degree of vasoconstriction to Ach was similar between the SES and PES groups. Endothelium-independent vasodilatation to nitrate did not differ significantly between the study groups.ConclusionsAbnormal vasoconstriction to Ach was found in the SES and PES groups, especially in arterial segments distal to DES at 6 months after stenting, which suggests that DES has a potential long-term adverse effect on local coronary endothelial dysfunction

    Critical heat flux enhancement in flow boiling of Al 2O 3 and SiC nanofluids under low pressure and low flow conditions

    Get PDF
    Critical heat flux (CHF) is the thermal limit of a phenomenon in which a phase change occurs during heating (such as bubbles forming on a metal surface used to heat water), which suddenly decreases the heat transfer efficiency, thus causing localized overheating of the heating surface. The enhancement of CHF can increase the safety margins and allow operation at higher heat fluxes; thus, it can increase the economy. A very interesting characteristic of nanofluids is their ability to significantly enhance the CHF. Nanofluids are nanotechnology-based colloidal dispersions engineered through the stable suspension of nanoparticles. All experiments were performed in round tubes with an inner diameter of 0.01041 m and a length of 0.5 m under low pressure and low flow (LPLF) conditions at a fixed inlet temperature using water, 0.01 vol.% Al2O3/water nanofluid, and SiC/water nanofluid. It was found that the CHF of the nanofluids was enhanced and the CHF of the SiC/water nanofluid was more enhanced than that of the Al2O3/water nanofluid.close6

    Mechanical Circulatory Support to Control Medically Intractable Arrhythmias in Pediatric Patients After Cardiac Surgery

    Get PDF
    Postoperative intractable arrhythmia can result in high morbidity and mortality. This report describes our experiences using mechanical circulatory support (MCS) to control medically intractable arrhythmias in three pediatric patients with congenital heart disease (CHD), after palliative or total corrective open-heart surgery

    Bare-metal stents versus drug-eluting stents in large (≥3.5mm) single coronary artery: Angiographic and clinical outcomes at 6 months

    Get PDF
    SummaryBackgroundAlthough drug-eluting stents (DES) have been shown to dramatically reduce restenosis and improve the rate of event-free survival in large randomized trials, the benefit of DES appears to be limited to restenosis. In large arteries, it is not clear which type of stent is more superior in angiographic and clinical outcomes between DES and bare-metal stents (BMS). We compared the angiographic and clinical outcomes of DES versus BMS in large arteries (≥3.5mm).MethodTwo hundred and forty patients from March 2002 to March 2007 received stents; 196 patients were treated with DES (44.9% sirolimus-eluting stents; 43.9% paclitaxel-eluting stents; 11.2% zotarolimus-eluting stents) and 44 with cobalt–chromium BMS for single de novo lesions in a large vessel. All subjects received aspirin, clopidogrel, and/or cilostazol as the standard antiplatelet regimen. The angiographic and clinical outcomes were evaluated at 6 months.ResultsFor the baseline characteristics, there were no significant differences between the DES and BMS groups. In addition, for the initially implanted stent there was no difference in the length, stent diameter, and lesion site between the two groups. After 6 months, the follow-up angiogram showed that in-stent diameter restenosis and late loss was more common with BMS than DES (39±21% vs. 19±17%, p=0.007; 1.44±0.83mm vs. 0.62±0.58mm, p=0.009, respectively). However, the target-lesion revascularization/target-vessel revascularization, and total major adverse cardiac events showed no significant differences between the groups (5.3% vs. 3.6%, p=0.62; 5.3% vs. 4.6%, p=0.86, respectively).ConclusionThe DES and cobalt–chromium BMS placed in large coronary arteries showed equally favorable 6-month clinical outcomes, although the 6-month angiographic results appeared more favorable in the DES group than in the BMS group

    Association of circulating omentin-1 level with arterial stiffness and carotid plaque in type 2 diabetes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Adipokines contribute directly to the atherosclerotic process, connecting metabolic disorders such as obesity and diabetes to cardiovascular disease. Omentin-1 is a recently discovered novel adipokine, so data about the relationship of this adipokine to vascular health in type 2 diabetes is limited.</p> <p>Methods</p> <p>We enrolled 60 people with type 2 diabetes, with or without carotid plaque, and 30 participants with normal glucose tolerance. We measured serum omentin-1, high-sensitivity C-reactive protein (hsCRP) levels, and the homeostasis model assessment of insulin resistance (HOMA-IR), as well as other cardiovascular risk factors. Vascular health was assessed by brachial ankle pulse wave velocity (baPWV) and carotid intima-media thickness (IMT).</p> <p>Results</p> <p>Serum omentin-1 levels were significantly decreased in type 2 diabetes patients compared to normal glucose controls and was further reduced in type 2 diabetes patients with carotid plaque compared to those without carotid plaque. Multiple stepwise regression analysis showed that age, systolic blood pressure, history of use of statins, angiotensin receptor blockers or angiotensin-converting enzyme inhibitors, and serum omentin-1 level were independent factors determining baPWV in people with type 2 diabetes (<it>r</it><sup>2 </sup>= 0.637). Furthermore, in multivariate logistic regression analysis, circulating omentin-1 level was an independent decisive factor for the presence of carotid plaque in type 2 diabetes patients, even after adjusting for age, gender, body mass index, systolic blood pressure, fasting blood glucose, low density lipoprotein cholesterol, and history of smoking and medication (odds ratio, 0.621; 95% confidence interval, 0.420-0.919; <it>P </it>= 0.017).</p> <p>Conclusions</p> <p>Circulating omentin-1 level was independently correlated with arterial stiffness and carotid plaque in type 2 diabetes, even after adjusting for other cardiovascular risk factors and detailed medication history.</p
    corecore