41 research outputs found

    Assessment of biodegradable controlled release rod systems for pain relief applications

    No full text
    Control of chronic, severe pain is a difficult and important clinical problem for most patients, especially those with cancer, Although current applications are insufficient for a satisfactory solution to this problem, the rate of disease incidence is increasing worldwide, thus making the problem more apparent. Based on this fact, this study was designed with the ultimate goal of formulating a controlled release system of pain relievers, mainly opioids, for the local treatment of pain to achieve satisfactory, fast, and less side effect-related relief and to provide a better life status for chronic pain patients. Two copolymers of a biodegradable polymer poly(L-lactide-co-glycolide) (PLGA) were used to prepare an implantable rod type drug release system containing either an analgesic or anesthetic type of pain reliever. In vitro drug release kinetics of these systems were studied. It was observed that release from PLGA 85: 15 was more zero-order than it was from PLGA 50: 50. A zero-order release rate was obtained for codeine, hydromorphone, and bupivacaine from PLGA (85: 15) rods. They, however, were released from PLGA (50: 50) rods with Higuchi kinetics. The drug solubility was also influential on release rate, as shown by the zero-order morphine release from PLGA (50:50) rods. Scanning electron micrographs (SEMs) of the monolithic rods revealed erosion of the rods and the removal of drug crystals from the rod structure

    In vivo pain relief effectiveness of an analgesic-anesthetic carrying biodegradable controlled release rod systems

    No full text
    Pain is the most common and feared symptom for patients, especially those with cancer. Treatment of chronic pain with conventional ways of medication usually fails with increasing severity of the pain. New approaches enabling the prolonged provision of pain relievers are required. We designed a controlled release system of pain relievers, mainly for opioids (morphine, M, codeine, C, and hydromorphone, HM), and a local anesthetic (bupivacaine, BP) in the form Of poly(L-lactide-colycolide) (PLGA) rods. The efficacy of these rods implanted alone or in combination in relieving chronic pain in rats caused by the ligation of the sciatic nerve of their right hind limbs was studied. The two most common tests for measuring analgesia, i.e. tail-flick tests, that show analgesia at sites other than the site of injury, were used to study the degree of systemic distribution of the drugs and paw-withdrawal tests were used to study the analgesia at the site of injury

    Antibiotic release from biodegradable PHBV microparticles

    No full text
    For the treatment of periodontal diseases, design of a controlled release system seemed very appropriate for an effective, long term result. In this study a novel, biodegradable microbial polyester, poly(3-hydroxybutyrate-co-3-hydroxyvalerate), PHBV of various valerate contents containing a well established antibiotic, tetracycline, known to be effective against many of the periodontal disease related microorganisms, was used in the construction of a controlled release system. Tetracycline was loaded in the PHBV microspheres and microcapsules both in its acidic (TC) and in neutral form (TCN). Microcapsules of PHBV were prepared under different conditions using w/o/w double emulsion and their properties such as encapsulation efficiency, loading, release characteristics, and morphological properties were investigated. It was found that concentration of emulsifiers polyvinyl alcohol (PVA) and gelatin (varied between 0-4%) influenced the encapsulation efficiency appreciably. In order to increase encapsulation efficiency (from the obtained range of 18.1-30.1%) and slow down the release of the highly soluble tetracycline. HCl, it was neutralized with NaOH. Encapsulation efficiency of neutralized tetracycline was much higher (51.9-65.3%) due to the insoluble form of the drug used during encapsulation. The release behaviour of neither of the drugs was found to be of zero order. Rather the trends fitted reasonably well to Higuchi's approach for release from spherical micropheres. Biodegradability was not an appreciable parameter in the release from microcapsules because release was complete before any signs of degradation were observed

    Antinociceptive effects of hydromorphone, bupivacaine and biphalin released from PLGA polymer after intrathecal implantation in rats

    No full text
    Intraspinal drug delivery, based on the concept of controlling pain by delivering drug to a nociceptive target rich in opioid and other relevant receptors is increasingly used clinically. The therapeutic ratio for opioids or other centrally acting agents is potentially greater if they are administered intrathecally (i.t.) than outside the central nervous system (CNS). The present study was designed with the ultimate goal of formulating a controlled release system for intrathecal analgesia characterized by effectiveness, rapid onset and few side effects for chronic pain control. A biodegradable copolymer poly(L-lactide-co-glycolide) (PLGA) was used to prepare a rod-shaped drug delivery system containing hydromorphone (HM), bupivacaine (BP), both HM and BP, or biphalin (131). In vitro drug release kinetics of these systems showed a zero-order release rate for HM and BP from PLGA (85:15) rods. Drug-loaded rods were implanted i.t. Control groups received only placebo implants. Measurement of analgesic efficacy was carried out with tail flick and paw-withdrawal tests. In vivo studies showed potent, prolonged analgesia in comparison to controls for all active treatments. Analgesic synergy was observed with HM and BP. With further refinements of drug release rate, these rods may offer a clinically relevant alternative for intrathecal analgesia
    corecore