3 research outputs found

    Time-to-effect guided pulmonary vein isolation utilizing the third-generation versus second generation cryoballoon: One year clinical success

    Get PDF
    Background: The second-generation cryoballoon (CB2) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging and reproducible clinical outcome data. The latest- -generation cryoballoon (CB3) incorporates a 40% shorter distal tip, thus allowing for an increased rate of PVI real-time signal recording and facilitating individualized ablation strategies taking the time-to- -effect (TTE) into account. However, whether this characteristic translates into favorable clinical success has not been evaluated yet. Herein was investigated 1-year clinical success after CB3 in comparison to CB2 based-PVI. Methods: One hundred and ten consecutive patients with paroxysmal or short-standing persistent atrial fibrillation (AF) underwent CB2 (n = 55 patients) -or CB3 (n = 55 patients) -based PVI. The freeze-cycle duration was set to TTE + 120 s if TTE could be recorded, otherwise a fixed freeze-cycle duration of 180 s was applied. Results: A total of 217/218 (99%, CB3) and 217/217 (100%, CB2) pulmonary veins (PV) were successfully isolated. The real-time PVI visualization rate was 69.2% (CB3) and 54.8% (CB2; p = 0.0392). The mean freeze-cycle duration was 194 ± 77 s (CB3) and 206 ± 85 s (CB2; p = 0.132), respectively. During a median follow-up of 409 days (interquartile range [IQR] 378–421, CB3) and 432 days (IQR 394–455, CB2) 73.6% (CB3) and 73.1% of patients (CB2) remained in stable sinus rhythm after a single procedure (p = 0.806). Conclusions: A higher rate of real-time electrical PV recordings was seen using the CB3 as compared to CB2. There was no difference in 1-year clinical follow-up

    Blocking LFA-1 Aggravates Cardiac Inflammation in Experimental Autoimmune Myocarditis

    Get PDF
    The lymphocyte function-associated antigen 1 (LFA-1) is a member of the beta2-integrin family and plays a pivotal role for T cell activation and leukocyte trafficking under inflammatory conditions. Blocking LFA-1 has reduced or aggravated inflammation depending on the inflammation model. To investigate the effect of LFA-1 in myocarditis, mice with experimental autoimmune myocarditis (EAM) were treated with a function blocking anti-LFA-1 antibody from day 1 of disease until day 21, the peak of inflammation. Cardiac inflammation was evaluated by measuring infiltration of leukocytes into the inflamed cardiac tissue using histology and flow cytometry and was assessed by analysis of the heart weight/body weight ratio. LFA-1 antibody treatment severely enhanced leukocyte infiltration, in particular infiltration of CD11b+ monocytes, F4/80+ macrophages, CD4+ T cells, Ly6G+ neutrophils, and CD133+ progenitor cells at peak of inflammation which was accompanied by an increased heart weight/body weight ratio. Thus, blocking LFA-1 starting at the time of immunization severely aggravated acute cardiac inflammation in the EAM model

    Time-to-effect guided pulmonary vein isolation utilizing the third-generation versus second generation cryoballoon: One year clinical success

    No full text
    The second-generation cryoballoon (CB2) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging and reproducible clinical outcome data. The latest-generation cryoballoon (CB3) incorporates a 40% shorter distal tip, thus allowing for an increased rate of PVI real-time signal recording and facilitating individualized ablation strategies taking the time-to-effect (TTE) into account. However, whether this characteristic translates into favorable clinical success has not been evaluated yet. Herein was investigated one-year clinical success after CB3 in comparison to CB2 based-PVI
    corecore