    Direct Current Electrical Stimulation Increases the Fusion Rate of Spinal Fusion Cages

    Get PDF
    Study Design. A randomized experimental evaluation of direct current stimulation in a validated animal model with an experimental control group, using blinded radiographic, biomechanical, histologic, and statistical measures. Objectives. To evaluate the efficacy of the adjunctive use of direct current stimulation on the fusion rate and speed of healing of titanium interbody fusion cages packed with autograft in a sheep lumbar interbody fusion model. Summary of Background Data. Titanium lumbar interbody spinal fusion cages have been reported to be 90% effective for single-level lumbar interbody fusion. However, fusion rates are reported to be between 70% and 80% in patients with multilevel fusions or with risk factors such as obesity, tobacco use, or metabolic disorders. The authors hypothesized that direct current stimulation would increase the fusion rate of titanium interbody fusion cages packed with autograft in a sheep lumbar interbody fusion model. Methods. Twenty-two sheep underwent lumbar discectomy and fusion at L4–L5 with an 11- × 20-mm Bagby and Kuslich (BAK) cage packed with autograft. Seven sheep received a BAK cage and no current. Seven sheep had a cage and a 40-μA current applied with a direct current stimulator. Eight sheep had a BAK cage and a 100-μA current applied. All sheep were killed 4 months after surgery. The efficacy of electrical stimulation in promoting interbody fusion was assessed by performing radiographic, biomechanical, and histologic analyses in a blinded fashion. Results. The histologic fusion rate increased as the direct current dose increased from 0 μA to 40 μA to 100 μA (P \u3c 0.009). Histologically, all animals in the 100-μA group had fusions in both the right and left sides of the cage. Direct current stimulation had a significant effect on increasing the stiffness of the treated motion segment in right lateral bending (P \u3c 0.120), left lateral bending (P \u3c 0.017), right axial rotation (P \u3c 0.004), left axial rotation (P \u3c 0.073), extension (P \u3c 0.078), and flexion (P \u3c 0.029) over nonstimulated levels. Conclusion. Direct current stimulation increased the histologic and biomechanical fusion rate and the speed of healing of lumbar interbody spinal fusion cages in an ovine model at 4 months

    Polyetheretherketone as a Biomaterial for Spinal Applications

    Get PDF
    Threaded lumbar interbody spinal fusion devices (TIBFD) made from titanium have been reported to be 90% effective for single-level lumbar interbody fusion, although radiographic determination of fusion has been intensely debated in the literature. Using blinded radiographic, biomechanic, histologic, and statistical measures, we evaluated a radiolucent polyetheretherketone (PEEK)-threaded interbody fusion device packed with autograft or rhBMP-2 on an absorbable collagen sponge in 13 sheep at 6 months. Radiographic fusion, increased spinal level biomechanical stiffness, and histologic fusion were demonstrated for the PEEK cages filled with autograft or rhBMP-2 on a collagen sponge. No device degradation or wear debris was observed. Only mild chronic inflammation consisting of a few macrophages was observed in peri-implant tissues. Based on these results, the polymeric biomaterial PEEK may be a useful biomaterial for interbody fusion cages due to the polymer\u27s increased radiolucency and decreased stiffness

    Bioresorbable Polylactide Interbody Implants in an Ovine Anterior Cervical Discectomy and Fusion Model: Three-Year Results

    Get PDF
    Study Design. In vivo study of anterior discectomy and fusion using a bioresorbable 70:30 poly(l-lactide-co-d,l-lactide) interbody implant in an ovine model. Objective. To evaluate the efficacy of the polylactide implant to function as an interbody fusion device, and to assess the tissue reaction to the material during the resorption process. Summary of Background Data. The use of polylactide as a cervical interbody implant has several potential advantages when compared with traditional materials. Having an elastic modulus very similar to bone minimizes the potential for stress shielding, and as the material resorbs additional loading is transferred to the developing fusion mass. Although preclinical and clinical studies have demonstrated the suitability of polylactide implants for lumbar interbody fusion, detailed information on cervical anterior cervical discectomy and fusion (ACDF) with polylactide devices is desirable. Methods. Single level ACDF was performed in 8 skeletally mature ewes. Bioresorbable 70:30 poly (l-lactide-co-d,l-lactide) interbody implants packed with autograft were used with single-level metallic plates. Radiographs were made every 3 months up to 1 year, and yearly thereafter. The animals were killed at 6 months (3 animals), 12 months (3 animals), and 36 months (2 animals). In addition to the serial plain radiographs, the specimens were evaluated by nondestructive biomechanical testing and undecalcified histologic analysis. Results. The bioresorbable polylactide implants were effective in achieving interbody fusion. The 6-month animals appeared fused radiographically and biomechanically, whereas histologic sections demonstrated partial fusion (in 3 of 3 animals). Radiographic fusion was confirmed histologically and biomechanically at 12 months (3 of 3 animals) and 36 months (2 of 2 animals). A mild chronic inflammatory response to the resorbing polylactide implant was observed at both 6 months and 12 months. At 36 months, the operative levels were solidly fused and the implants were completely resorbed. No adverse tissue response was observed in any animal at any time period. Conclusion. Interbody fusion was achieved using bioresorbable polylactide implants, with no evidence of implant collapse, extrusion, or adverse tissue response to the material. The use of polylactide as a cervical interbody device appears both safe and effective based on these ACDF animal model results

    Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model.

    Get PDF
    Background contextThere is significant variability in the materials commonly used for interbody cages in spine surgery. It is theorized that three-dimensional (3D)-printed interbody cages using porous titanium material can provide more consistent bone ingrowth and biological fixation.PurposeThe purpose of this study was to provide an evidence-based approach to decision-making regarding interbody materials for spinal fusion.Study designA comparative animal study was performed.MethodsA skeletally mature ovine lumbar fusion model was used for this study. Interbody fusions were performed at L2-L3 and L4-L5 in 27 mature sheep using three different interbody cages (ie, polyetheretherketone [PEEK], plasma sprayed porous titanium-coated PEEK [PSP], and 3D-printed porous titanium alloy cage [PTA]). Non-destructive kinematic testing was performed in the three primary directions of motion. The specimens were then analyzed using micro-computed tomography (µ-CT); quantitative measures of the bony fusion were performed. Histomorphometric analyses were also performed in the sagittal plane through the interbody device. Outcome parameters were compared between cage designs and time points.ResultsFlexion-extension range of motion (ROM) was statistically reduced for the PTA group compared with the PEEK cages at 16 weeks (p-value=.02). Only the PTA cages demonstrated a statistically significant decrease in ROM and increase in stiffness across all three loading directions between the 8-week and 16-week sacrifice time points (p-value≤.01). Micro-CT data demonstrated significantly greater total bone volume within the graft window for the PTA cages at both 8 weeks and 16 weeks compared with the PEEK cages (p-value<.01).ConclusionsA direct comparison of interbody implants demonstrates significant and measurable differences in biomechanical, µ-CT, and histologic performance in an ovine model. The 3D-printed porous titanium interbody cage resulted in statistically significant reductions in ROM, increases in the bone ingrowth profile, as well as average construct stiffness compared with PEEK and PSP

    Transient Local Bone Remodeling Effects of rhBMP-2 in an Ovine Interbody Spine Fusion Model

    Get PDF
    Background: Recombinant human bone morphogenetic protein-2 (rhBMP-2) is a powerful osteoinductive morphogen capable of stimulating the migration of mesenchymal stem cells (MSCs) to the site of implantation and inducing the proliferation and differentiation of these MSCs into osteoblasts. Vertebral end-plate and vertebral body resorption has been reported after interbody fusion with high doses of rhBMP-2. In this study, we investigated the effects of 2 rhBMP-2 doses on peri-implant bone resorption and bone remodeling at 7 time points in an end-plate-sparing ovine interbody fusion model. Methods: Twenty-one female sheep underwent an end-plate-sparing discectomy followed by interbody fusion at L2-L3 and L4-L5 using a custom polyetheretherketone (PEEK) interbody fusion device. The PEEK interbody device was filled with 1 of 2 different doses of rhBMP-2 on an absorbable collagen sponge (ACS): 0.13 mg (1·) or 0.90 mg (7·). Bone remodeling and interbody fusion were assessed via high-resolution radiography and histological analyses at 1, 2, 3, 4, 8, 12, and 20 weeks postoperatively. Results: Peri-implant bone resorption peaked between 3 and 8 weeks in both the 1· and the 7· rhBMP-2/ACS-dose group. Osteoclastic activity and corresponding peri-implant bone resorption was dose-dependent, with moderate-tomarked resorption at the 7·-dose level and less resorption at the 1·-dose level. Both dose (p \u3c 0.0007) and time (p \u3c 0.0025) affected bone resorption significantly. Transient bone-resorption areas were fully healed by 12 weeks. Osseous bridging was seen at all but 1 spinal level at 12 and at 20 weeks. Conclusions: In the ovine end-plate-sparing interbody fusion model, rhBMP-2 dose-dependent osteoclastic resorption is a transient phenomenon that peaks at 4 weeks postoperatively. Clinical Relevance: Using the U.S. Food and Drug Administration (FDA)-approved rhBMP-2 concentration and matching the volume of rhBMP-2/ACS with the volume of desired bone formation within the interbody construct may limit the occurrence of transient bone resorption

    Reduction in postlaminectomy epidural adhesions in sheep using a fibrin sealant-based medicated adhesion barrier

    Full text link
    Epidural adhesion formation is believed to be a central governing factor in the prevalence of pain after spinal surgery and is regarded as being the primary instigator of neural tethering, leading to complications during revision surgery. In this study, we assess the effectiveness and safety of fibrin sealant supplemented with tributyrin, termed Medicated Adhesion Barrier (MAB), as an alternative means of reducing the incidence of posterior spinal epidural adhesion formation. Laminectomy defects in sheep were treated with MAB, fibrin sealant alone, ADCONGel, or remained untreated. At 12 weeks postoperatively, the extent of fibrosis and epidural adhesion formation was evaluated using magnetic resonance imaging (MRI), peel-off testing, and histological examination. Initial invitro analysis revealed that tributyrin was retained in fibrin gel in a time-dependent manner and was an effective inhibitor of fibroblast proliferation. Treatment of sheep with MAB significantly reduced both the prevalence (p < 0.05) and tenacity (p < 0.05) of epidural adhesions. The effectiveness of MAB in preventing epidural adhesions was found to be comparable with that of ADCONGel. No adverse events were reported after the use of MAB. The MAB preparation seems to be an effective resorbable barrier for the prevention of epidural adhesions

    In vivo evaluation of bioresorbable polylactide implants for cervical graft containment in an ovine spinal fusion model.

    No full text
    OBJECT: An in vivo study was conducted in an ovine model to investigate the biomechanical changes after the animals underwent single-level anterior cervical discectomy followed by fusion in which autologous tricortical graft was used and implantation of cervical plates for which bioresorbable polymer screws and plates were used. The specific aims of the study were to evaluate whether implant failure or screw backout would occur over time and to measure the change in stiffness at the treated level at various postoperative time periods (3, 6, and 12 months). METHODS: A total of 58 x-ray films were evaluated over the 12-month survival period. No screw breakage or displacement was observed in any animal during the temporal radiographic analysis. Radiographically confirmed fusion appeared to be complete at all time periods longer than 6 months. The biomechanical testing demonstrated dramatic reductions in range of motion at the fusion level in the animals allowed to survive for 6 and 12 months, indicating complete fusion after 6 months. CONCLUSIONS: The bioresorbable polymer cervical graft containment system appears to provide a safe and effective alternative for cervical fusion, and warrants further clinical evaluation for its use in single-level anterior cervical discectomy and fusion without postoperative orthosis

    In vivo evaluation of bioresorbable polylactide implants for cervical graft containment in an ovine spinal fusion model

    No full text
    OBJECT: An in vivo study was conducted in an ovine model to investigate the biomechanical changes after the animals underwent single-level anterior cervical discectomy followed by fusion in which autologous tricortical graft was used and implantation of cervical plates for which bioresorbable polymer screws and plates were used. The specific aims of the study were to evaluate whether implant failure or screw backout would occur over time and to measure the change in stiffness at the treated level at various postoperative time periods (3, 6, and 12 months). METHODS: A total of 58 x-ray films were evaluated over the 12-month survival period. No screw breakage or displacement was observed in any animal during the temporal radiographic analysis. Radiographically confirmed fusion appeared to be complete at all time periods longer than 6 months. The biomechanical testing demonstrated dramatic reductions in range of motion at the fusion level in the animals allowed to survive for 6 and 12 months, indicating complete fusion after 6 months. CONCLUSIONS: The bioresorbable polymer cervical graft containment system appears to provide a safe and effective alternative for cervical fusion, and warrants further clinical evaluation for its use in single-level anterior cervical discectomy and fusion without postoperative orthosis