50 research outputs found

    Iridium complex, a phosphorescent light-emitting diode material, serves as a novel chemical probe for imaging hypoxic tumor tissues

    Get PDF
    Iridium complex, a promising organic light-emitting diode for next generation television displays, emits phosphorescence. Phosphorescence is quenched by oxygen. We used this oxygen-quenching feature for imaging tumor hypoxia. Red light-emitting iridium complex Ir(btp)~2~(acac) (BTP) presented hypoxia-dependent light emission in culture cell lines, whose intensity was in parallel with HIF-1[alpha] expression. BTP was further applied to imaging five tumors (four from human origin and one from mouse origin) transplanted in athymic mice. All tumors presented a bright BTP-emitting image even 5 min after the injection. The BTP-dependent tumor image peaked at 1 to 2 h after the injection, and was then cleared from tumors within 24 h. The minimal BTP image recognition size was 3 to 4 mm in diameter. Compared with ^18^F-FDG/PET images, BTP delineated a clearer image for a tumor profile. We suggest that iridium complex has a vast potential for imaging hypoxic lesions such as tumor tissues

    Fluorescence-based endoscopic imaging of Thomsen–Friedenreich antigen to improve early detection of colorectal cancer

    Get PDF
    Thomsen–Friedenreich (TF) antigen belongs to the mucin-type tumor-associated carbohydrate antigen. Notably, TF antigen is overexpressed in colorectal cancer (CRC) but is rarely expressed in normal colonic tissue. Increased TF antigen expression is associated with tumor invasion and metastasis. In this study, we sought to validate a novel nanobeacon for imaging TF-associated CRC in a preclinical animal model. We developed and characterized the nanobeacon for use with fluorescence colonoscopy. In vivo imaging was performed on an orthotopic rat model of CRC. Both white light and fluorescence colonoscopy methods were utilized to establish the ratio-imaging index for the probe. The nanobeacon exhibited specificity for TF-associated cancer. Fluorescence colonoscopy using the probe can detect lesions at the stage which is not readily confirmed by conventional visualization methods. Further, the probe can report the dynamic change of TF expression as tumor regresses during chemotherapy. Data from this study suggests that fluorescence colonoscopy can improve early CRC detection. Supplemented by the established ratio-imaging index, the probe can be used not only for early detection, but also for reporting tumor response during chemotherapy. Furthermore, since the data obtained through in vivo imaging confirmed that the probe was not absorbed by the colonic mucosa, no registered toxicity is associated with this nanobeacon. Taken together, these data demonstrate the potential of this novel probe for imaging TF antigen as a biomarker for the early detection and prediction of the progression of CRC at the molecular level

    Ratiometric Molecular Probes Based on Dual Emission of a Blue Fluorescent Coumarin and a Red Phosphorescent Cationic Iridium(III) Complex for Intracellular Oxygen Sensing

    No full text
    Ratiometric molecular probes RP1 and RP2 consisting of a blue fluorescent coumarin and a red phosphorescent cationic iridium complex connected by a tetra- or octaproline linker, respectively, were designed and synthesized for sensing oxygen levels in living cells. These probes exhibited dual emission with good spectral separation in acetonitrile. The photorelaxation processes, including intramolecular energy transfer, were revealed by emission quantum yield and lifetime measurements. The ratios (RI = (Ip /If) ) between the phosphorescence (Ip) and fluorescence (If) intensities showed excellent oxygen responses; the ratio of RI under degassed and aerated conditions ( R I 0 MathType@MTEF@5@5@+= feaagKart1ev2aqatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY=Hhbbf9v8qqaqFr0xc9pk0xbb a9q8WqFfeaY=biLkVcLq=JHqpepeea0=as0Fb9pgeaYRXxe9vr0=vr 0=vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaabaaaaaaaaape GaamOua8aadaqhaaWcbaWdbiaadMeaa8aabaWdbiaaicdaaaaaaa@38D6@ / RI) was 20.3 and 19.6 for RP1 and RP2. The introduction of the cationic Ir (III) complex improved the cellular uptake efficiency compared to that of a neutral analogue with a tetraproline linker. The emission spectra of the ratiometric probes internalized into living HeLa or MCF-7 cells could be obtained using a conventional microplate reader. The complex RP2 with an octaproline linker provided ratios comparable to the ratiometric measurements obtained using a microplate reader: the ratio of the  value of RP2 under hypoxia (2.5% O2) to that under normoxia (21% O2) was 1.5 and 1.7 for HeLa and MCF-7 cells, respectively. Thus, the intracellular oxygen levels of MCF-7 cells could be imaged by ratiometric emission measurements using the complex RP2

    Analysis of the triplet-state kinetics of a photosensitizer for photoimmunotherapy by fluorescence correlation spectroscopy

    Get PDF
    Herein, we evaluated the intersystem crossing quantum yield (Phi(ISC)) of a silicon phthalocyanine derivatized from IRDye700DX (IR700) which is used as a photosensitizer for photoimmunotherapy (PIT), using fluorescence correlation spectroscopy (FCS). The calculated Phi(ISC) was 0.019 +/- 0.002. The FCS measurement was validated by experiment in the presence of potassium iodide, which can change the kinetics of the relaxation process in the excited state
    corecore