49 research outputs found

    The deceleration of full metal jacket bullets in compact target models - A new approach.

    Get PDF
    The wounding potential of a projectile depends on its kinetic energy. The aim of the study was to investigate the deceleration of non-deforming full metal jacket handgun bullets (FMJ) in gelatine blocks of increasing length. The temporary cavity (TC) was visualized using a SA-X2 Photron camera. 126 test shots in 9 mm nominal calibre were fired under strict temperature control conditions (4°C) at small gelatine blocks ranging from 2 to 12 cm in length. The deposited energy was calculated based on the loss of bullet velocity through high-speed video analysis. The length of the TC was measured, when the TC reached its maximum height. The volume of the TC was approximated by a cylinder. Regression analysis showed a linear correlation between the length of the bullet path and the energy transfer. The constant deceleration of the FMJ bullets in gelatine up to 12 cm bullet path was confirmed across various brands and velocity ranges (270-450 m/s). Higher impact velocities correlated with increased loss of energy in the target medium. The shape of the bullet tip influenced the characteristic of deceleration. The volume of the tubular temporary cavity, derived from high-speed video records, was found to be proportional to the energy transferred. The proposed approach might be a valuable tool in advancing wound ballistics research

    Validation and evaluation of measuring methods for the 3D documentation of external injuries in the field of forensic medicine.

    Get PDF
    Three-dimensional (3D) measurement techniques are gaining importance in many areas. The latest developments brought more cost-effective, user-friendly, and faster technologies onto the market. Which 3D techniques are suitable in the field of forensic medicine and what are their advantages and disadvantages? This wide-ranging study evaluated and validated various 3D measurement techniques for the forensic requirements. High-tech methods as well as low-budget systems have been tested and compared in terms of accuracy, ease of use, expenditure of time, mobility, cost, necessary knowhow, and their limitations. Within this study, various commercial measuring systems of the different techniques were tested. Based on the first results, one measuring system was selected for each technique, which appeared to be the most suitable for the forensic application or is already established in forensic medicine. A body of a deceased, a face and an injury of a living person, and a shoe sole were recorded by 11 people with different professions and previous knowledge using the selected systems. The results were assessed and the personal experiences were evaluated using a questionnaire. In addition, precision investigations were carried out using test objects. The study shows that the hand-held scanner and photogrammetry are very suitable for the 3D documentation of forensic medical findings. Their moderate acquisition costs and easy operation could lead to more frequent application in forensic medicine in the future. For special applications, the stripe-light scanner still has its justification due to its high precision, the flexible application area, and the high reliability. The results show that, thanks to the technological advances, the 3D measurement technology will have more and more impact on the routine of the forensic medical examination

    The reference cube: A new ballistic model to generate staining in firearm barrels

    No full text
    After contact shots to the head biological traces can be found inside firearm barrels. So far silicone coated, gelatin filled box models were used to generate such staining according to the triple contrast method (mixture of acrylic paint, barium sulfate and blood sealed in a thin foil bag). This study was conducted to develop a transparent ballistic model allowing contact shots. Gelatin filled polyethylene bottles with and without a silicone coat were tested in comparison to non-covered gelatin blocks. Finally, thin foil bags of 5 cm × 5 cm dimension were glued on a synthetic absorbent kitchen wipe on top of which 1 L 10% gelatin solution was molded to create blocks of 8.5 cm length. A kitchen wipe with a paint pad on its inside formed the front of the cube. Three contact shots each with a 9 mm Luger pistol and a .38 special revolver were performed on all model variations. The staining was documented by endoscopy and swabs gathered from both ends of the barrel were analyzed by quantitative PCR. Reliable staining was achieved using the front covered gelatin block with comparable results to the silicone coated box model used before. For further research using ballistic models to simulate a human head a symmetric form of the gelatin block such as a cube is recommended

    Aufnahmeposition von Smartphone-Fotos

    No full text

    Body weight estimation based on postmortem CT data—validation of a multiplication factor

    No full text
    Postmortem computed tomography (pmCT) is increasingly applied in forensic medicine as a documentation and diagnostic tool. The present study investigated if pmCT data can be used to estimate the corpse weight. In 50 forensic cases, pmCT examinations were performed prior to autopsy and the pmCT data were used to determine the body volume using an automated segmentation tool. PmCT was performed within 48h postmortem. The body weights assessed prior to autopsy and the body volumes assessed using the pmCT data were used to calculate individual multiplication factors. The mean postmortem multiplication factor for the study cases was 1.07g/ml. Using this factor, the body weight may be estimated retrospectively when necessary. Severe artifact causing foreign bodies within the corpses limit the use of pmCT data for body weight estimations
    corecore