    Randomized crossover comparison of proportional assist ventilation and patient-triggered ventilation in extremely low birth weight infants with evolving chronic lung disease

    Get PDF
    Background: Refinement of ventilatory techniques remains a challenge given the persistence of chronic lung disease of preterm infants. Objective: To test the hypothesis that proportional assist ventilation ( PAV) will allow to lower the ventilator pressure at equivalent fractions of inspiratory oxygen (FiO(2)) and arterial hemoglobin oxygen saturation in ventilator-dependent extremely low birth weight infants in comparison with standard patient-triggered ventilation ( PTV). Methods: Design: Randomized crossover design. Setting: Two level-3 university perinatal centers. Patients: 22 infants ( mean (SD): birth weight, 705 g ( 215); gestational age, 25.6 weeks ( 2.0); age at study, 22.9 days ( 15.6)). Interventions: One 4- hour period of PAV was applied on each of 2 consecutive days and compared with epochs of standard PTV. Results: Mean airway pressure was 5.64 ( SD, 0.81) cm H2O during PAV and 6.59 ( SD, 1.26) cm H2O during PTV ( p < 0.0001), the mean peak inspiratory pressure was 10.3 ( SD, 2.48) cm H2O and 15.1 ( SD, 3.64) cm H2O ( p < 0.001), respectively. The FiO(2) ( 0.34 (0.13) vs. 0.34 ( 0.14)) and pulse oximetry readings were not significantly different. The incidence of arterial oxygen desaturations was not different ( 3.48 ( 3.2) vs. 3.34 ( 3.0) episodes/ h) but desaturations lasted longer during PAV ( 2.60 ( 2.8) vs. 1.85 ( 2.2) min of desaturation/ h, p = 0.049). PaCO2 measured transcutaneously in a subgroup of 12 infants was similar. One infant met prespecified PAV failure criteria. No adverse events occurred during the 164 cumulative hours of PAV application. Conclusions: PAV safely maintains gas exchange at lower mean airway pressures compared with PTV without adverse effects in this population. Backup conventional ventilation breaths must be provided to prevent apnea-related desaturations. Copyright (c) 2007 S. Karger AG, Base

    A system for the automatic measurement and digital display of systolic and diastolic blood pressures

    Get PDF
    Basic components of system are - occluding cuff with mounted cuff microscope, cuff pump deflator, pressure transducer, preamplifier unit, electrocardiograph machine, an analog to digital convertor unit, and digital display unit. System utilizes indirect auscultatory method, based on Korotkoff sounds, for measurement

    Grain orientation in high Tc superconductors by molten salt powder synthesis

    Get PDF
    The molten salt or the flux method is used to fabricate a grain oriented YBa2Cu3O(7-x) (123) superconductor. Here we suggest a two-stage approach in using the 'green phase', Y2BaCuO5 (211), as seed crystals in the formation of YBa2Cu3O(7-x). The process uses Y2BaCuO5 formed by molten salt synthesis. The Y2BaCuO5 phase was observed to be stable in water and in most of the salt systems. Salt processing can form a small quantity of anisotropic particles of Y2BaCuO5. This material can form the 123 phase when tape cast and sintered in the presence of the required levels of Ba and Cu

    XPS characterization of silver electrodes and catalyst for oxygen reduction

    Get PDF
    The combined analysis of the silver GDE using an ex-situ surface sensitive technique (XPS) and in-situ electrochemical measurements (EIS, CV) show that the performance of the silver GDE is significantly influenced by the degree of degradation of the electrodes, e. g., the reduction of the active surface due to the decomposition of the PTFE. These findings indicate a different degree of decomposition of the PTFE on the on the GDE
    • …