2,074 research outputs found

    Grid simulation services for the medical community

    No full text
    The first part of this paper presents a selection of medical simulation applications, including image reconstruction, near real-time registration for neuro-surgery, enhanced dose distribution calculation for radio-therapy, inhaled drug delivery prediction, plastic surgery planning and cardio-vascular system simulation. The latter two topics are discussed in some detail. In the second part, we show how such services can be made available to the clinical practitioner using Grid technology. We discuss the developments and experience made during the EU project GEMSS, which provides reliable, efficient, secure and lawful medical Grid services

    The ability of the National Early Warning Score (NEWS) to discriminate patients at risk of early cardiac arrest, unanticipated intensive care unit admission, and death

    Get PDF
    INTRODUCTION: Early warning scores (EWS) are recommended as part of the early recognition and response to patient deterioration. The Royal College of Physicians recommends the use of a National Early Warning Score (NEWS) for the routine clinical assessment of all adult patients. METHODS: We tested the ability of NEWS to discriminate patients at risk of cardiac arrest, unanticipated intensive care unit (ICU) admission or death within 24h of a NEWS value and compared its performance to that of 33 other EWSs currently in use, using the area under the receiver-operating characteristic (AUROC) curve and a large vital signs database (n=198,755 observation sets) collected from 35,585 consecutive, completed acute medical admissions. RESULTS: The AUROCs (95% CI) for NEWS for cardiac arrest, unanticipated ICU admission, death, and any of the outcomes, all within 24h, were 0.722 (0.685-0.759), 0.857 (0.847-0.868), 0.894 (0.887-0.902), and 0.873 (0.866-0.879), respectively. Similarly, the ranges of AUROCs (95% CI) for the other 33 EWSs were 0.611 (0.568-0.654) to 0.710 (0.675-0.745) (cardiac arrest); 0.570 (0.553-0.568) to 0.827 (0.814-0.840) (unanticipated ICU admission); 0.813 (0.802-0.824) to 0.858 (0.849-0.867) (death); and 0.736 (0.727-0.745) to 0.834 (0.826-0.842) (any outcome). CONCLUSIONS: NEWS has a greater ability to discriminate patients at risk of the combined outcome of cardiac arrest, unanticipated ICU admission or death within 24h of a NEWS value than 33 other EWSs

    Calorimetric readout of a superconducting proximity-effect thermometer

    Full text link
    A proximity-effect thermometer measures the temperature dependent critical supercurrent in a long superconductor - normal metal - superconductor (SNS) Josephson junction. Typically, the transition from the superconducting to the normal state is detected by monitoring the appearance of a voltage across the junction. We describe a new approach to detect the transition based on the temperature increase in the resistive state due to Joule heating. Our method increases the sensitivity and is especially applicable for temperatures below about 300 mK.Comment: 10 pages, 5 figures. To appear in the proceedings of the Conference on Micro- and Nanocryogenics (LT25 satellite) organized in Espoo, Finland (2008

    A Comparison of the Quick Sequential (Sepsis-Related) Organ Failure Assessment Score and the National Early Warning Score in Non-ICU Patients With/Without Infection.

    Get PDF
    OBJECTIVES: The Sepsis-3 task force recommended the quick Sequential (Sepsis-Related) Organ Failure Assessment score for identifying patients with suspected infection who are at greater risk of poor outcomes, but many hospitals already use the National Early Warning Score to identify high-risk patients, irrespective of diagnosis. We sought to compare the performance of quick Sequential (Sepsis-Related) Organ Failure Assessment and National Early Warning Score in hospitalized, non-ICU patients with and without an infection. DESIGN: Retrospective cohort study. SETTING: Large U.K. General Hospital. PATIENTS: Adults hospitalized between January 1, 2010, and February 1, 2016. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We applied the quick Sequential (Sepsis-Related) Organ Failure Assessment score and National Early Warning Score to 5,435,344 vital signs sets (241,996 hospital admissions). Patients were categorized as having no infection, primary infection, or secondary infection using International Classification of Diseases, 10th Edition codes. National Early Warning Score was significantly better at discriminating in-hospital mortality, irrespective of infection status (no infection, National Early Warning Score 0.831 [0.825-0.838] vs quick Sequential [Sepsis-Related] Organ Failure Assessment 0.688 [0.680-0.695]; primary infection, National Early Warning Score 0.805 [0.799-0.812] vs quick Sequential [Sepsis-Related] Organ Failure Assessment 0.677 [0.670-0.685]). Similarly, National Early Warning Score performed significantly better in all patient groups (all admissions, emergency medicine admissions, and emergency surgery admissions) for all outcomes studied. Overall, quick Sequential (Sepsis-Related) Organ Failure Assessment performed no better, and often worse, in admissions with infection than without. CONCLUSIONS: The National Early Warning Score outperforms the quick Sequential (Sepsis-Related) Organ Failure Assessment score, irrespective of infection status. These findings suggest that quick Sequential (Sepsis-Related) Organ Failure Assessment should be reevaluated as the system of choice for identifying non-ICU patients with suspected infection who are at greater risk of poor outcome

    Inherent thermometry in a hybrid superconducting tunnel junction

    Full text link
    We discuss inherent thermometry in a Superconductor - Normal metal - Superconductor tunnel junction. In this configuration, the energy selectivity of single-particle tunneling can provide a significant electron cooling, depending on the bias voltage. The usual approach for measuring the electron temperature consists in using an additional pair of superconducting tunnel junctions as probes. In this paper, we discuss our experiment performed on a different design with no such thermometer. The quasi-equilibrium in the central metallic island is discussed in terms of a kinetic equation including injection and relaxation terms. We determine the electron temperature by comparing the micro-cooler experimental current-voltage characteristic with isothermal theoretical predictions. The limits of validity of this approach, due to the junctions asymmetry, the Andreev reflection or the presence of sub-gap states are discussed

    Influence of temperature gradients on tunnel junction thermometry below 1 K: cooling and electron-phonon coupling

    Full text link
    We have studied thermal gradients in thin Cu and AlMn wires, both experimentally and theoretically. In the experiments, the wires were Joule heated non-uniformly at sub-Kelvin temperatures, and the resulting temperature gradients were measured using normal metal-insulator-superconducting tunnel junctions. The data clearly shows that even in reasonably well conducting thin wires with a short (10μ\sim 10 \mum) non-heated portion, significant temperature differences can form. In most cases, the measurements agree well with a model which includes electron-phonon interaction and electronic thermal conductivity by the Wiedemann-Franz law.Comment: J. Low Temp. Phys. in pres

    Tilt Modulus and Angle-Dependent Flux Lattice Melting in the Lowest Landau Level Approximation

    Full text link
    For a clean high-Tc_c superconductor, we analyze the Lawrence-Doniach free energy in a tilted magnetic field within the lowest Landau level (LLL) approximation. The free energy maps onto that of a strictly cc-axis field, but with a reduced interlayer coupling. We use this result to calculate the tilt modulus C44C_{44} of a vortex lattice and vortex liquid. The vortex contribution to C44C_{44} can be expressed in terms of the squared cc-axis Josephson plasmon frequency ωpl2\omega_{pl}^2. The transverse component of the field has very little effect on the position of the melting curve.Comment: 8 pages, 2 figures, accepted for publication in Physical Review B (Rapid Communications

    Relative Oscillation Theory, Weighted Zeros of the Wronskian, and the Spectral Shift Function

    Full text link
    We develop an analog of classical oscillation theory for Sturm-Liouville operators which, rather than measuring the spectrum of one single operator, measures the difference between the spectra of two different operators. This is done by replacing zeros of solutions of one operator by weighted zeros of Wronskians of solutions of two different operators. In particular, we show that a Sturm-type comparison theorem still holds in this situation and demonstrate how this can be used to investigate the finiteness of eigenvalues in essential spectral gaps. Furthermore, the connection with Krein's spectral shift function is established.Comment: 26 page

    Optimization in a Self-Stabilizing Service Discovery Framework for Large Scale Systems

    Get PDF
    Ability to find and get services is a key requirement in the development of large-scale distributed sys- tems. We consider dynamic and unstable environments, namely Peer-to-Peer (P2P) systems. In previous work, we designed a service discovery solution called Distributed Lexicographic Placement Table (DLPT), based on a hierar- chical overlay structure. A self-stabilizing version was given using the Propagation of Information with Feedback (PIF) paradigm. In this paper, we introduce the self-stabilizing COPIF (for Collaborative PIF) scheme. An algo- rithm is provided with its correctness proof. We use this approach to improve a distributed P2P framework designed for the services discovery. Significantly efficient experimental results are presented
    corecore