809 research outputs found

    Interpretation of the prominence differential emissions measure for 3 geometries

    Get PDF
    Researchers have used prominence extreme ultraviolet line intensities observed from Skylab to derive the differential emission measure Q(T) in the prominence-corona (PC) interface from 3 x 10,000 to 3 times 1 million K, including the effects of Lyman Continuum absorption. Using lines both shortward and longward of the Lyman limit, researchers have estimated the importance of absorption as function of temperature. The magnitude of the absorption, as well as its rate of increase as a function of temperature, place limits on the thread scales and the character of the interfilar medium. Researchers have calculated models based on three assumed geometries: (1) threads with hot sheaths and cool cores; (2) isothermal threads; and (3) threads with longitudinal temperature gradients along the magnetic field. Comparison of the absorption computed from these models with the observed absorption in prominences shows that none of the geometries is totally satisfactory

    Meterwave observations of a coronal hole

    Get PDF
    Meter-wave maps are presented showing a coronal hole at 30.9, 50.0, and 73.8 MHz using the Clark Lake Radioheliograph in October 1984. The coronal hole seen against the disk at all three frequencies shows interesting similarities to, and significant differences from its optical signatures in HeI lambda10830 spectroheliograms. The 73.8 MHz coronal hole, when seen near disk center, appears to coincide with the HeI footprint of the hole. At the lower frequencies, the emission comes from higher levels of the corona, and the hole appears to be displaced, probably due to the non-radial structure of the coronal hole. The contrast of the hole relative to the quiet Sun is much greater than reported previously for a coronal hole observed at 80 MHz. The higher contrast is certainly real, due to the superior dynamic range, sensitivity, and calibration of the Clark Lake instrument. Using a coronal hole model, the electron density is derived from radio observations of the brightness temperature. A very large discrepancy is found between the derived density and that determined from Skylab EUV observations of coronal holes. This discrepancy suggests that much of the physics of coronal holes has yet to be elucidated

    On the Photometric Accuracy of RHESSI Imaging and Spectrosocopy

    Full text link
    We compare the photometric accuracy of spectra and images in flares observed with the Ramaty High Energy Solar Spectroscopic Imager (RHESSI)}spacecraft. We test the accuracy of the photometry by comparing the photon fluxes obtained in different energy ranges from the spectral-fitting software SPEX with those fluxes contained in the images reconstructed with the Clean, MEM, MEM-Vis, Pixon, and Forward-fit algorithms. We quantify also the background fluxes, the fidelity of source geometries, and spatial spectra reconstructed with the five image reconstruction algorithms. We investigate the effects of grid selection, pixel size, field-of-view, and time intervals on the quality of image reconstruction. The detailed parameters and statistics are provided in an accompanying CD-ROM and web page. We find that Forward-fit, Pixon, and Clean have a robust convergence behavior and a photometric accuracy in the order of a few percents, while MEM does not converge optimally for large degrees of freedom (for large field-of-views and/or small pixel sizes), and MEM-Vis suffers in the case of time-variable sources. This comparative study documents the current status of the RHESSI spectral and imaging software, one year after launch.Comment: 2 Figures, full version on http://www.lmsal.com/~aschwand/eprints/2003_photo/index.htm

    RHESSI Observations of a Simple Large X-ray Flare on 11-03-2003

    Full text link
    We present data analysis and interpretation of a simple X-class flare observed with RHESSI on November 3, 2003. In contrast to other X-class flares observed previously, this flare shows a very simple morphology with well defined looptop (LT) and footpoint (FP) sources. The almost monotonic upward motion of the LT source and increase in separation of the two FP sources are consistent with magnetic reconnection models proposed for solar flares. In addition, we find that the source motions are relatively slower during the more active phases of hard X-ray emission; the emission centroid of the LT source shifts toward higher altitudes with the increase of energy; the separation between the LT emission centroids at two different photon energies is anti-correlated with the FP flux. Non-uniformity of the reconnecting magnetic fields could be a possible explanation of these features.Comment: To appear in the Astrophysical Journal Letters (12 pages, 4 figures

    Fast Time Structure During Transient Microwave Brightenings: Evidence for Nonthermal Processes

    Get PDF
    Transient microwave brightenings (TMBs) are small-scale energy releases from the periphery of sunspot umbrae, with a flux density two orders of magnitude smaller than that from a typical flare. Gopalswamy et al (1994) first reported the detection of the TMBs and it was pointed out that the radio emission implied a region of very high magnetic field so that the emission mechanism has to be gyroresonance or nonthermal gyrosynchrotron, but not free-free emission. It was not possible to decide between gyroresonance and gyrosynchrotron processes because of the low time resolution (30 s) used in the data analysis. We have since performed a detailed analysis of the Very Large Array data with full time resolution (3.3 s) at two wavelengths (2 and 3.6 cm) and we can now adequately address the question of the emission mechanism of the TMBs. We find that nonthermal processes indeed take place during the TMBs. We present evidence for nonthermal emission in the form of temporal and spatial structure of the TMBs. The fast time structure cannot be explained by a thermodynamic cooling time and therefore requires a nonthermal process. Using the physical parameters obtained from X-ray and radio observations, we determine the magnetic field parameters of the loop and estimate the energy released during the TMBs. The impulsive components of TMBs imply an energy release rate of 1.3 x 10^22 erg/s so that the thermal energy content of the TMBs could be less than 10^24 erg.Comment: 15 pages (Latex), 4 figures (eps). ApJ Letters in press (1997

    Solar Flare Physics

    Get PDF
    We have continued our previous efforts in studies of fourier imaging methods applied to hard X-ray flares. We have performed physical and theoretical analysis of rotating collimator grids submitted to GSFC(Goddard Space Flight Center) for the High Energy Solar Spectroscopic Imager (HESSI). We have produced simulation algorithms which are currently being used to test imaging software and hardware for HESSI. We have developed Maximum-Entropy, Maximum-Likelihood, and "CLEAN" methods for reconstructing HESSI images from count-rate profiles. This work is expected to continue through the launch of HESSI in July, 2000. Section 1 shows a poster presentation "Image Reconstruction from HESSI Photon Lists" at the Solar Physics Division Meeting, June 1998; Section 2 shows the text and viewgraphs prepared for "Imaging Simulations" at HESSI's Preliminary Design Review on July 30, 1998

    Quantitative characterization of the x-ray imaging capability of rotating modulation collimators with laser light

    Get PDF
    We developed a method for making quantitative characterizations of bi-grid rotating modulation collimators (RMC ’s) that are used in a Fourier transform x-ray imager. With appropriate choices of the collimator spacings, this technique can be implemented with a beam-expanded He -Ne laser to simulate the plane wave produced by a point source at infinity even though the RMC ’s are diffraction limited at the He -Ne wavelength of 632.8 nm. The expanded beam passes through the grid pairs at a small angle with respect to their axis of rotation, and the modulated transmission through the grids as the RMC ’s rotate is detected with a photomultiplier tube. In addition to providing a quantitative characterization of the RMC ’s, the method also produces a measured point response function and provides an end-to-end check of the imaging system. We applied our method to the RMC ’s on the high-energy imaging device (HEIDI) balloon payload in its preflight configuration. We computed the harmonic ratios of the modulation time profile from the laser measurements and compared them with theoretical calculations, including the diffraction effects on irregular grids. Our results indicate the 25-in. (64-cm) x-ray imaging optics on HEIDI are capable of achieving images near the theoretical limit and are not seriously compromised by imperfections in the grids
    • …
    corecore