4 research outputs found

    Innovative organotypic in vitro models for safety assessment: aligning with regulatory requirements and understanding models of the heart, skin, and liver as paradigms

    Get PDF
    The development of improved, innovative models for the detection of toxicity of drugs, chemicals, or chemicals in cosmetics is crucial to efficiently bring new products safely to market in a cost-effective and timely manner. In addition, improvement in models to detect toxicity may reduce the incidence of unexpected post-marketing toxicity and reduce or eliminate the need for animal testing. The safety of novel products of the pharmaceutical, chemical, or cosmetics industry must be assured; therefore, toxicological properties need to be assessed. Accepted methods for gathering the information required by law for approval of substances are often animal methods. To reduce, refine, and replace animal testing, innovative organotypic in vitro models have emerged. Such models appear at different levels of complexity ranging from simpler, self-organized three-dimensional (3D) cell cultures up to more advanced scaffold-based co-cultures consisting of multiple cell types. This review provides an overview of recent developments in the field of toxicity testing with in vitro models for three major organ types: heart, skin, and liver. This review also examines regulatory aspects of such models in Europe and the UK, and summarizes best practices to facilitate the acceptance and appropriate use of advanced in vitro models

    A convolutional neural network trained with dermoscopic images performed on par with 145 dermatologists in a clinical melanoma image classification task

    No full text
    Background: Recent studies have demonstrated the use of convolutional neural networks (CNNs) to classify images of melanoma with accuracies comparable to those achieved by board-certified dermatologists. However, the performance of a CNN exclusively trained with dermoscopic images in a clinical image classification task in direct competition with a large number of dermatologists has not been measured to date. This study compares the performance of a convolutional neuronal network trained with dermoscopic images exclusively for identifying melanoma in clinical photographs with the manual grading of the same images by dermatologists. Methods: We compared automatic digital melanoma classification with the performance of 145 dermatologists of 12 German university hospitals. We used methods from enhanced deep learning to train a CNN with 12,378 open-source dermoscopic images. We used 100 clinical images to compare the performance of the CNN to that of the dermatologists. Dermatologists were compared with the deep neural network in terms of sensitivity, specificity and receiver operating characteristics. Findings: The mean sensitivity and specificity achieved by the dermatologists with clinical images was 89.4% (range: 55.0%-100%) and 64.4% (range: 22.5%-92.5%). At the same sensitivity, the CNN exhibited a mean specificity of 68.2% (range 47.5%-86.25%). Among the dermatologists, the attendings showed the highest mean sensitivity of 92.8% at a mean specificity of 57.7%. With the same high sensitivity of 92.8%, the CNN had a mean specificity of 61.1%. Interpretation: For the first time, dermatologist-level image classification was achieved on a clinical image classification task without training on clinical images. The CNN had a smaller variance of results indicating a higher robustness of computer vision compared with human assessment for dermatologic image classification tasks. (C) 2019 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

    Deep learning outperformed 136 of 157 dermatologists in a head-to-head dermoscopic melanoma image classification task

    No full text
    Background: Recent studies have successfully demonstrated the use of deep-learning algorithms for dermatologist-level classification of suspicious lesions by the use of excessive proprietary image databases and limited numbers of dermatologists. For the first time, the performance of a deep-learning algorithm trained by open-source images exclusively is compared to a large number of dermatologists covering all levels within the clinical hierarchy. Methods: We used methods from enhanced deep learning to train a convolutional neural network (CNN) with 12,378 open-source dermoscopic images. We used 100 images to compare the performance of the CNN to that of the 157 dermatologists from 12 university hospitals in Germany. Outperformance of dermatologists by the deep neural network was measured in terms of sensitivity, specificity and receiver operating characteristics. Findings: The mean sensitivity and specificity achieved by the dermatologists with dermoscopic images was 74.1% (range 40.0%-100%) and 60% (range 21.3%-91.3%), respectively. At a mean sensitivity of 74.1%, the CNN exhibited a mean specificity of 86.5% (range 70.8%-91.3%). At a mean specificity of 60%, a mean sensitivity of 87.5% (range 80%-95%) was achieved by our algorithm. Among the dermatologists, the chief physicians showed the highest mean specificity of 69.2% at a mean sensitivity of 73.3%. With the same high specificity of 69.2%, the CNN had a mean sensitivity of 84.5%. Interpretation: A CNN trained by open-source images exclusively outperformed 136 of the 157 dermatologists and all the different levels of experience (from junior to chief physicians) in terms of average specificity and sensitivity. (C) 2019 The Author(s). Published by Elsevier Ltd
    corecore