9 research outputs found

    Comparison of two different generations of "nIRS" devices and transducers in healthy volunteers and ICU patients

    No full text
    The purpose of this study is to compare Near Infrared Spectroscopy (NIRS) thenar eminence parameters obtained with 2 different devices from the same manufacturer (InSpectra Models 325 and 650, Hutchinson Tech, Min USA), and 2 different probes (15 vs. 25 mm spacing), in healthy volunteers (HV) and ICU patients. Prospective, observational study in ICU setting. Simultaneous, cross over NIRS inter-device comparison and comparison between different probes (25 vs. 15 mm spacing) were done at baseline and during vascular occlusion tests (VOTs). Forty patients (19 septic shock, 21 trauma), and 29 HV were included. NIRS inter-device comparison showed similar baseline StO2 values in HV and patients. The VOT result were significantly different for minimal StO2 value reached during VOT (StO2min) (intraclass concordance coefficient (ICC) = 0.18), the occlusion slope (ICC = 0.16) and the reperfusion slope (StO2reperf) (ICC = 0.26). The probe comparison was also significantly different for VOT parameters (StO2min (ICC = 0.43), occlusion (ICC = 0.50) and StO2reperf (ICC = 0.48). The low concordance, poor agreement and large bias (ICC and Bland & Altman) observed, were related both to the device used and the probe spacing. StO 2 data obtained with NIRS model 650 and 15 mm probe differ from values obtained with the previous device (325 and probe spacing 25 or 15 mm). This difference is not related to the population tested, but to the device and probe spacing. As a consequence, despite similar trends for variations between HV and patients during VOT, threshold and predictive values for outcome should be revisited with the new device before the acceptance for routine clinical use. © 2012 Springer Science+Business Media New York.SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    Therapeutic anti-integrin (α4 and αL) monoclonal antibodies: two-edged swords?

    No full text
    Anti-α4 and anti-αL integrin chain monoclonal antibodies have shown a clear-cut beneficial effect in different animal models of autoimmune and inflammatory disorders as well as in human diseases, including multiple sclerosis, inflammatory bowel disease, and psoriasis. It has been widely assumed that this therapeutic effect is mainly consequence of the blockade of leucocyte adhesion to endothelium, inhibiting thus their extravasation and the inflammatory phenomenon. However, it is evident that both α4β1 (very late antigen-4) and αLβ2 (leucocyte function-associated antigen-1) integrins have additional important roles in other immune phenomena, including the formation of the immune synapse and the differentiation of T helper 1 lymphocytes. Therefore, it is very feasible that the long-term administration of blocking agents directed against these integrins to patients with inflammatory/autoimmune conditions may have undesirable or unexpected effects

    Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications

    Get PDF
    Conventional cardiovascular monitoring may not detect tissue hypoxia, and conventional cardiovascular support aiming at global hemodynamics may not restore tissue oxygenation. NIRS offers non-invasive online monitoring of tissue oxygenation in a wide range of clinical scenarios. NIRS monitoring is commonly used to measure cerebral oxygenation (rSO(2)), e.g. during cardiac surgery. In this review, we will show that tissue hypoxia occurs frequently in the perioperative setting, particularly in cardiac surgery. Therefore, measuring and obtaining adequate tissue oxygenation may prevent (postoperative) complications and may thus be cost-effective. NIRS monitoring may also be used to detect tissue hypoxia in (prehospital) emergency settings, where it has prognostic significance and enables monitoring of therapeutic interventions, particularly in patients with trauma. However, optimal therapeutic agents and strategies for augmenting tissue oxygenation have yet to be determined

    Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine