9 research outputs found

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Clinical outcomes of a trifocal compared with an EDOF IOL following bilateral cataract surgery

    No full text
    OBJECTIVE: To compare the visual and patient reported outcomes of 2 presbyopia-correcting intraocular lenses (IOLs). METHODS: A total of 134 eyes (67 patients) that underwent cataract surgery with either a trifocal IOL or an extended depth of focus (EDOF) IOL bilaterally and were assessed 3 months after surgery. Outcome measures were binocular distance-corrected visual acuity at near (40 cm), intermediate (60 cm), and distance (6 m); Akman modified Quality of Life (QOL) Questionnaire-14; and 10% contrast visual acuity at distance and near, with and without glare. RESULTS: Mean binocular logMAR visual acuity (VA) for the PanOptix compared with the Symfony lenses: distance-corrected near VA, 0.054 versus 0.228; distance-corrected intermediate VA, 0.019 versus 0.063; and distance-corrected distance VA, -0.016 versus -0.021. The QOL questionnaire showed that 62% of the PanOptix group and 48% of the Symfony group had little or no difficulty with all QOL-related tasks. In a multivariable model controlling for pupil size and angle kappa (chord mu distance, right eyes), the differences were -0.005 (range, -0.03-0.02) and 0.165 (range, 0.12-0.21), respectively. Also, 10% contrast acuity was comparable in the 2 different lenses and was unaffected by glare. CONCLUSIONS: Binocular distance-corrected near VA was significantly better in the PanOptix group (p < 0.0001). This result remained statistically significant after controlling for pupil size and chord mu distance (p < 0.001). Intermediate and distance VAs were similar between the 2 groups. QOL scores were higher in the PanOptix group

    The value of routine polymerase chain reaction analysis of intraocular fluid specimens in the diagnosis of infectious posterior uveitis

    Get PDF
    Objective. To assess the value of routine polymerase chain reaction (PCR) analysis on intraocular fluid from patients presenting with a first episode of suspected active infectious posterior uveitis in a population with a high prevalence of human immunodeficiency virus infection. Design. Retrospective, interventional case series. Participants. 159 consecutive patients presenting at a tertiary care hospital over a five-year period. Methods. PCR analysis was performed for cytomegalovirus, varicella zoster virus, herpes simplex virus types 1 and 2, Toxoplasma gondii, and Mycobacterium tuberculosis. Results. PCR analysis confirmed the initial clinical diagnosis in 55 patients (35%) and altered the initial clinical diagnosis in 36 patients (23%). The clinical diagnosis prior to PCR testing was nonspecific (uncertain) in 51 patients (32%), with PCR providing a definitive final diagnosis in 20 of these patients (39%); necrotizing herpetic retinopathy and ocular toxoplasmosis were particularly difficult to diagnose correctly without the use of PCR analysis. Conclusion. The clinical phenotype alone was unreliable in diagnosing the underlying infectious cause in a quarter of patients in this study. Since the outcome of incorrectly treated infective uveitis can be blinding, PCR analysis of ocular fluids is recommended early in the disease even in resource poor settings

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between Mar

    Nutzenbewertung von Trainingsinterventionen für die Sturzprophylaxe bei älteren Menschen - eine systematische Übersicht auf der Grundlage systematischer Übersichten

    No full text

    Femoral Neck Shortening After Hip Fracture Fixation Is Associated With Inferior Hip Function : Results From the FAITH Trial

    No full text

    Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures

    No full text

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    corecore