125 research outputs found

    Posterior eye shape measurement with retinal OCT compared to MRI

    Get PDF
    PURPOSE. Posterior eye shape assessment by magnetic resonance imaging (MRI) is used to study myopia. We tested the hypothesis that optical coherence tomography (OCT), as an alternative, could measure posterior eye shape similarly to MRI. METHODS. Macular spectral-domain OCT and brain MRI images previously acquired as part of the Singapore Epidemiology of Eye Diseases study were analyzed. The right eye in the MRI and OCT images was automatically segmented. Optical coherence tomography segmentations were corrected for optical and display distortions requiring biometry data. The segmentations were fitted to spheres and ellipsoids to obtain the posterior eye radius of curvature (Rc) and asphericity (Qxz). The differences in Rc and Qxz measured by MRI and OCT were tested using paired t-tests. Categorical assignments of prolateness or oblateness using Qxz were compared. RESULTS. Fifty-two subjects (67.8 ± 5.6 years old) with spherical equivalent refraction from +0.50 to -5.38 were included. The mean paired difference between MRI and original OCT posterior eye Rc was 24.03 ± 46.49 mm (P = 0.0005). For corrected OCT images, the difference in Rc decreased to -0.23 ± 2.47 mm (P = 0.51). The difference between MRI and OCT asphericity, Qxz, was -0.052 ± 0.343 (P = 0.28). However, categorical agreement was only moderate (j = 0.50). CONCLUSIONS. Distortion-corrected OCT measurements of Rc and Qxz were not statistically significantly different from MRI, although the moderate categorical agreement suggests that individual differences remained. This study provides evidence that with distortion correction, noninvasive office-based OCT could potentially be used instead of MRI for the study of posterior eye shape

    Genome-wide meta-analysis of myopia and hyperopia provides evidence for replication of 11 loci

    Get PDF
    Refractive error (RE) is a complex, multifactorial disorder characterized by a mismatch between the optical power of the eye and its axial length that causes object images to be focused off the retina. The two major subtypes of RE are myopia (nearsightedness) and hyperopia (farsightedness), which represent opposite ends of the distribution of the quantitative measure of spherical refraction. We performed a fixed effects meta-analysis of genome-wide association results of myopia and hyperopia from 9 studies of European-derived populations: AREDS, KORA, FES, OGP-Talana, MESA, RSI, RSII, RSIII and ERF. One genome-wide significant region was observed for myopia, corresponding to a previously identified myopia locus on 8q12 (p = 1.25610-8), which has been reported by Kiefer et al. as significantly associated with myopia age at onset and Verhoeven et al. as significantly associated to mean spherical-equivalent (MSE) refractive error. We observed two genomewide significant association

    Mendelian randomization analysis does not support causal associations of birth weight with hypertension risk and blood pressure in adulthood

    Get PDF
    Epidemiology studies suggested that low birthweight was associated with a higher risk of hypertension in later life. However, little is known about the causality of such associations. In our study, we evaluated the causal association of low birthweight with adulthood hypertension following a standard analytic protocol using the study-level data of 183,433 participants from 60 studies (CHARGE-BIG consortium), as well as that with blood pressure using publicly available summary-level genome-wide association data from EGG consortium of 153,781 participants, ICBP consortium and UK Biobank cohort together of 757,601 participants. We used seven SNPs as the instrumental variable in the study-level analysis and 47 SNPs in the summary-level analysis. In the study-level analyses, decreased birthweight was associated with a higher risk of hypertension in adults (the odds ratio per 1 standard deviation (SD) lower birthweight, 1.22; 95% CI 1.16 to 1.28), while no association was found between genetically instrumented birthweight and hypertension risk (instrumental odds ratio for causal effect per 1 SD lower birthweight, 0.97; 95% CI 0.68 to 1.41). Such results were consistent with that from the summary-level analyses, where the genetically determined low birthweight was not associated with blood pressure measurements either. One SD lower genetically determined birthweight was not associated with systolic blood pressure (β = − 0.76, 95% CI − 2.45 to 1.08 mmHg), 0.06 mmHg lower diastolic blood pressure (β = − 0.06, 95% CI − 0.93 to 0.87 mmHg), or pulse pressure (β = − 0.65, 95% CI − 1.38 to 0.69 mmHg, all p > 0.05). Our findings suggest that the inverse association of birthweight with hypertension risk from observational studies was not supported by large Mendelian randomization analyses

    Issues and Challenges for Myopia Research

    No full text
    Annals of the Academy of Medicine Singapore3311-3AAMS

    Is it Possible to Slow the Progression of Myopia?

    No full text
    Annals of the Academy of Medicine Singapore3314-6AAMS

    Interventions for Branch Retinal Vein Occlusion. An Evidence-Based Systematic Review

    No full text
    10.1016/j.ophtha.2007.01.010Ophthalmology114

    Hypermetropia, Axial Length, and Hypertension: The Tanjong Pagar Survey

    No full text
    10.1016/j.ajo.2006.01.020American Journal of Ophthalmology14161142-114

    Prevalence of overweight and obesity in Chinese preschoolers in Singapore

    No full text
    Annals of the Academy of Medicine Singapore42266-72AAMS
    corecore