53 research outputs found

    Optical trapping in micro- and nanoconfinement systems: Role of thermo-fluid dynamics and applications

    Get PDF
    In this mini-review, recent advances on the role of a focused laser in micro- and nanofluidic systems is widely introduced with special interest in thermo-fluid dynamical aspects and their importance in optical manipulation. As a brief introduction to microfluidic systems, we describe the advantages and challenges of the use of micro- and nanoscale confinement in optical trapping, as well as standard fabrication techniques for micro- and nanofluidic systems. From thermo-fluid dynamical viewpoints, various phenomena that accompany a laser irradiation to fluidic devices, are explained in detail. These phenomena can affect the optical trapping of target materials significantly, and are classified into two categories: one that induces the fluid flow around the target and another that directly acts on it as an external force. These classes are reviewed by shedding light on some recent cutting-edge researches for optical manipulation. Some applications using thermo-fluid dynamics in microfluidic systems for the measurement of optical forces and for the separation, measurement, and detection of target materials are also introduced

    Separation of long DNA chains using non-uniform electric field: a numerical study

    Get PDF
    We study migration of DNA molecules through a microchannel with a series of electric traps controlled by an ac electric field. We describe the motion of DNA based on Brownian dynamics simulations of a beads-spring chain. Our simulation demonstrates that the chain captured by an electrode escapes from the binding electric field due to thermal fluctuation. We find that the mobility of chain would depend on the chain length; the mobility sharply increases when the length of a chain exceeds a critical value, which is strongly affected by the amplitude of the applied ac field. Thus we can adjust the length regime, in which this microchannel well separates DNA molecules, without changing the structure of the channel. We also present a theoretical insight into the relation between the critical chain length and the field amplitude.Comment: 12 pages, 9 figure

    Electrochemical response of biased nanoelectrodes in solution

    Full text link
    Novel approaches to DNA sequencing and detection require the measurement of electrical currents between metal probes immersed in ionic solution. Here, we experimentally demonstrate that these systems maintain large background currents with a transient response that decays very slowly in time and noise that increases with ionic concentration. Using a non-equilibrium stochastic model, we obtain an analytical expression for the ionic current that shows these results are due to a fast electrochemical reaction at the electrode surface followed by the slow formation of a diffusion layer. During the latter, ions translocate in the weak electric field generated after the initial rapid screening of the strong fields near the electrode surfaces. Our theoretical results are in very good agreement with experimental findings

    A Preliminary Prototype High-Speed Feedback Control of an Artificial Cochlear Sensory Epithelium Mimicking Function of Outer Hair Cells

    No full text
    A novel feedback control technique for the local oscillation amplitude in an artificial cochlear sensory epithelium that mimics the functions of the outer hair cells in the cochlea is successfully developed and can be implemented with a control time on the order of hundreds of milliseconds. The prototype artificial cochlear sensory epithelium was improved from that developed in our previous study to enable the instantaneous determination of the local resonance position based on the electrical output from a bimorph piezoelectric membrane. The device contains local patterned electrodes deposited with micro electro mechanical system (MEMS) technology that is used to detect the electrical output and oscillate the device by applying local electrical stimuli. The main feature of the present feedback control system is the principle that the resonance position is recognized by simultaneously measuring the local electrical outputs of all of the electrodes and comparing their magnitudes, which drastically reduces the feedback control time. In this way, it takes 0.8 s to control the local oscillation of the device, representing the speed of control with the order of one hundred times relative to that in the previous study using the mechanical automatic stage to scan the oscillation amplitude at each electrode. Furthermore, the intrinsic difficulties in the experiment such as the electrical measurement against the electromagnetic noise, adhesion of materials, and fatigue failure mechanism of the oscillation system are also shown and discussed in detail based on the many scientific aspects. The basic knowledge of the MEMS fabrication and the experimental measurement would provide useful suggestions for future research. The proposed preliminary prototype high-speed feedback control can aid in the future development of fully implantable cochlear implants with a wider dynamic range

    Oscillation Characteristics of an Artificial Cochlear Sensory Epithelium Optimized for a Micrometer-Scale Curved Structure

    No full text
    Based on the modern microelectromechanical systems technology, we present a revolutionary miniaturized artificial cochlear sensory epithelium for future implantation tests on guinea pigs. The device was curved to fit the spiral structure of the cochlea and miniaturized to a maximum dimension of <1 mm to be implanted in the cochlea. First, the effect of the curved configuration on the oscillation characteristics of a trapezoidal membrane was evaluated using the relatively larger devices, which had a trapezoidal and a comparable curved shape designed for high-precision in vitro measurements. Both experimental and numerical analyses were used to determine the resonance frequencies and positions, and multiple oscillation modes were clearly observed. Because the maximum oscillation amplitude positions, i.e., the resonance positions, differed depending on the resonance frequencies in both trapezoidal and curved membrane devices, the sound frequency was determined based on the resonance position, thus reproducing the frequency selectivity of the basilar membrane in the organ of Corti. Furthermore, the resonance frequencies and positions of these two devices with different configurations were determined to be quantitatively consistent and similar in terms of mechanical dynamics. This result shows that despite a curved angle of 50–60°, the effect of the curved shape on oscillation characteristics was negligible. Second, the nanometer-scale oscillation of the miniaturized device was successfully measured, and the local resonance frequency in air was varied from 157 to 277 kHz using an experimental system that could measure the amplitude distribution in a two-dimensional (2D) plane with a high accuracy and reproducibility at a high speed. The miniaturized device developed in this study was shown to have frequency selectivity, and when the device was implanted in the cochlea, it was expected to discriminate frequencies in the same manner as the basilar membrane in the biological system. This study established methods for fabricating and evaluating the miniaturized device, and the proposed miniaturized device in a curved shape demonstrated the feasibility of next-generation cochlear implants

    Modeling of single-particle translocation through a low-aspect-ratio nanopore

    No full text
    corecore