30 research outputs found

    Enteroviruses in Patients with Acute Encephalitis, Uttar Pradesh, India

    Get PDF
    An outbreak of viral encephalitis occurred in northern India in 2006. Attempts to identify an etiologic agent in cerebrospinal fluid by using reverse transcription–PCR showed positivity to enterovirus (EV) in 66 (21.6%) of 306 patients. Sequencing and phylogenetic analyses of PCR products from 59 (89.3%) of 66 specimens showed similarity with EV-89 and EV-76 sequences

    Enteroviruses in Patients with Acute Encephalitis, Uttar Pradesh, India

    Get PDF
    An outbreak of viral encephalitis occurred in northern India in 2006. Attempts to identify an etiologic agent in cerebrospinal fluid by using reverse transcription–PCR showed positivity to enterovirus (EV) in 66 (21.6%) of 306 patients. Sequencing and phylogenetic analyses of PCR products from 59 (89.3%) of 66 specimens showed similarity with EV-89 and EV-76 sequences

    Optimization and Stability Testing of Four Commercially Available Dried Blood Spot Devices for Estimating Measles and Rubella IgG Antibodies.

    Get PDF
    Blood collection using dried blood spots (DBS) provides an easier alternative to venipuncture for sample collection, transport, and storage but requires additional processing that can cause variability in results. Whole-blood samples spotted on four DBS devices and respective paired serum samples were tested for antimeasles and antirubella IgG antibody concentrations by enzyme immunoassay. Elution protocols for DBS devices were optimized for comparability relative to serum samples using 12 adult volunteers. Stability of DBS collected on HemaSpot HF was assessed under various temperature conditions (+4, 22 to 25, and 45°C) at six time points (0, 7, 15, 30, 60, and 90 days) in a controlled laboratory setting using six adult volunteers. Devices were shipped and stored for 30 days at four settings with variable temperature and humidity conditions to assess the impact on antibody concentrations. Three DBS devices demonstrated comparable antibody concentrations with paired sera following optimization. Antibodies recovered from DBS were stable for at least 90 days at 4°C and for 30 days at ambient temperature (22 to 25°C) using the HemaSpot HF device. A drastic decline in antibody concentrations was observed at 45°C, resulting in quantitative and qualitative discrepancies by day 7. HemaSpot HF devices shipped to field sites and stored at ambient temperature and humidity resulted in quantitative, but not qualitative, variability. Measurement of antimeasles and antirubella IgG antibodies with DBS devices is an accurate alternative to testing serum, provided elution protocols are optimized. Stability of HemaSpot HF devices at ambient temperature enables broader use in surveys when serum processing and cold storage are not feasible. IMPORTANCE Dried blood spot (DBS) collection offers various advantages over conventional methods of blood collection, especially when collecting and transporting samples for a serosurvey. Yet use of DBS requires additional processing steps in the laboratory that can add to variability in results. We optimized a protocol to elute IgG antibodies against measles and rubella viruses in four DBS devices, demonstrating high concordance with paired venous sera for most devices. Extensive stability studies with various temperature and storage conditions in the laboratory and in the field were conducted using HemaSpot HF DBS devices prior to its use in one of the largest community-based measles and rubella serological surveys in the world

    Experiences of sharing results of community based serosurvey with participants in a district of Maharashtra, India.

    Get PDF
    A growing number of organisations, including medical associations, recommend that research subjects should be given the option of being informed about the general outcome and results of the study. We recently completed a study involving nine serosurveys from 2018 to 2020 in five districts of India among three age groups (children 9 months to < 5 years; 5 to < 15 years of age, and women 15 to < 50 years of age before and after the measles and rubella (MR) vaccination campaigns). In Palghar district of Maharashtra all individuals in 30 selected clusters were enumerated, and 13 individuals per age group were randomly sampled. We established the procedures to return the results to the respondents for each stage of the survey. Of the 1,166 individuals selected for the measles and rubella serosurvey, 971 (83%) agreed to participate and were enrolled. Participants were informed that they will only be contacted if they test seronegative for measles and/or rubella antibodies. Overall, 140 individuals enrolled in the survey tested seronegative for IgG antibodies to measles and/or rubella viruses; were provided the reports and informed to seek medical advice. Upon follow up by phone, 10% (14) of the 140 participants reported to have been vaccinated. In this paper we discuss the procedures, experiences and considerations in returning results to participants in a community-based measles and rubella serosurvey. Although the lessons learned are specific to post measles-rubella vaccine campaign serosurvey in India, they might be helpful to those contemplating sharing results to participants of large scale survey settings

    Implementing Serosurveys in India: Experiences, Lessons Learned, and Recommendations.

    Get PDF
    Serological surveillance for vaccine-preventable diseases, such as measles and rubella, can provide direct measures of population immunity across age groups, identify gaps in immunity, and document changes in immunity over time. Rigorously conducted, representative household serosurveys provide high-quality estimates with minimal bias. However, they can be logistically challenging, expensive, and have higher refusal rates than vaccine coverage surveys. This article shares lessons learned through implementing nine measles and rubella household serosurveys in five districts in India-the challenges faced, the potential impact on results, and recommendations to facilitate the conduct of serosurveys. Specific lessons learned arose from challenges related to community mobilization owing to lack of cooperation in certain settings and populations, limitations of outdated census information, nonresponse due to refusal or unavailability during survey enumeration and enrollment, data collection issues, and specimen collection and handling issues. Although some experiences are specific to serosurveys in India, these lessons are generalizable to other household surveys, particularly vaccination coverage and serosurveys conducted in low- and middle-income settings

    Diagnostic Accuracy of Dried Blood Spots Collected on HemaSpot HF Devices Compared to Venous Blood Specimens To Estimate Measles and Rubella Seroprevalence.

    Get PDF
    Fingerprick blood spotted onto filter paper offers an alternative to venous blood for use in population-based surveillance because it is comparatively inexpensive, acceptable, and easy to manage in the field. Prior studies have shown excellent agreement for immunoglobulin G (IgG) antibody detection from dried blood spots (DBS) and venous blood samples. However, much of this evidence is from high-income settings or laboratories where the samples were unlikely to be exposed to extreme temperatures and humidity, factors known to degrade DBS. We report the diagnostic accuracy of DBS collected using HemaSpot HF devices against venous sera in measuring measles- and rubella-specific IgG antibodies in a household serosurvey conducted in two districts in India. Paired serum and DBS samples collected by fingerprick were collected from women aged 15 to 50 years enrolled in a serosurvey in Palghar District of Maharashtra and Kanpur Nagar District of Uttar Pradesh in India. Specimen quality and volume were assessed in the laboratory. Samples were tested for antimeasles and antirubella IgG antibodies by an enzyme-linked immunosorbent assay (ELISA) (Euroimmun). Sensitivity of antibody detection by DBS was greater than 98%, and specificity was 90% and 98%, for measles and rubella IgG, respectively. Antibody concentrations were strongly correlated between paired specimens with adequate volume (measles R2 = 0.94; rubella R2 = 0.89). Although correlation was poor if DBS specimens had lower volumes, impact on qualitative results was minimal. This study showed DBS collected with HemaSpot HF devices can generate highly accurate results of measles- and rubella-specific IgG compared to sera in community-based surveys when protocols are optimized for DBS specimens. IMPORTANCE Dried blood spot (DBS) collection provides an easy, practical, and acceptable alternative to venous blood collection, especially for community-based studies, provided that results from DBS are accurate. We demonstrated high sensitivity and specificity for measles- and rubella-specific immunoglobulin G (IgG) with DBS collected via HemaSpot HF devices compared to serum samples. This is one of the largest community-based diagnostic accuracy studies of measles and rubella antibody testing with DBS and the first application we are aware of using HemaSpot HF device for measles and rubella serology. Results support the use of DBS in community-based serosurveillance

    Seroprevalence of Japanese encephalitis virus & West Nile virus in Alappuzha district, Kerala

    No full text
    Background & objectives: Several outbreaks of acute encephalitis syndrome (AES) have been reported in Alappuzha district, Kerala State, India, in the past. The aetiology of these outbreaks was either inconclusive or concluded as probable Japanese encephalitis virus (JEV) infection based on clinical presentation. The role of West Nile virus (WNV) in AES outbreaks was also determined. However, the extent of WNV infection has not been studied in this region previously. A population-based cross-sectional serosurvey study was undertaken to determine the seroprevalence of JEV and WNV in Alappuzha district. Methods: A total of 30 clusters were identified from 12 blocks and five municipalities as per the probability proportional to size sampling method. A total of 1125 samples were collected from all age groups. A microneutralization assay was performed to estimate the prevalence of JEV and WNV neutralizing antibodies in the sample population. Results: Of 1125 serum samples tested, 235 [21.5%, 95% confidence interval (CI): 15.2-27.8%] and 179 (15.9%, 95% CI: 9.6-22.3%) were positive for neutralizing antibodies against WNV and JEV, respectively. In addition, 411 (34.5%, 95% CI: 26.7-42.2%) were positive for cross-reactive antibodies against flaviviruses. Interpretation & conclusions: The study showed the seroprevalence of WNV and JEV antibodies in the surveyed area and the WNV seroprevalence was greater than JEV. It is necessary to create awareness in public and adopt suitable policy to control these diseases

    Zika virus: Indian perspectives

    No full text
    The emergence of Zika virus (ZiV), a mosquito borne Flavivirus like dengue (DEN) and chikungunya (CHIK), in Brazil in 2014 and its spread to various countries have led to a global health emergency. Aedes aegypti is the major vector for ZiV. Fast dissemination of this virus in different geographical areas posses a major threat especially to regions where the population lacks herd immunity against the ZiV and there is abundance of Aedes mosquitoes. In this review, we focus on current global scenario, epidemiology, biology, diagnostic challenges and remedial measures for ZiVconsidering the Indian perspective
    corecore