24 research outputs found

    Absence of mutations in PAX8, NKX2.5, and TSH receptor genes in patients with thyroid dysgenesis

    Get PDF
    Objectives: To precisely classify the various forms of TD, and then to screen for mutations in transcription factor genes active in thyroid development. Subjects and methods: Patients underwent ultrasound, thyroid scan, and serum thyroglobulin measurement to accurately diagnose the form of TD. DNA was extracted from peripheral leukocytes. The PAX8, and NKX2.5 genes were evaluated in all patients, and TSH receptor ( TSHR) gene in those with hypoplasia. Results: In 27 nonconsanguineous patients with TD, 13 were diagnosed with ectopia, 11 with hypoplasia, and 3 with athyreosis. No mutations were detected in any of the genes studied. Conclusion: Sporadic cases of TD are likely to be caused by epigenetic factors, rather than mutations in thyroid transcription factors or genes involved in thyroid development. Arq Bras Endocrinol Metab. 2012;56(3):173-7Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (Fapesp) [06/05800-1, 08/04786-0]Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP

    68 Ga-PSMA-11 PET/MRI versus multiparametric MRI in men referred for prostate biopsy: primary tumour localization and interreader agreement

    Full text link
    Background: Magnetic resonance imaging (MRI) is recommended by the European Urology Association guidelines as the standard modality for imaging-guided biopsy. Recently positron emission tomography with prostate-specific membrane antigen (PSMA PET) has shown promising results as a tool for this purpose. The aim of this study was to compare the accuracy of positron emission tomography with prostate-specific membrane antigen/magnetic resonance imaging (PET/MRI) using the gallium-labeled prostate-specific membrane antigen (68Ga-PSMA-11) and multiparametric MRI (mpMRI) for pre-biopsy tumour localization and interreader agreement for visual and semiquantitative analysis. Semiquantitative parameters included apparent diffusion coefficient (ADC) and maximum lesion diameter for mpMRI and standardized uptake value (SUVmax) and PSMA-positive volume (PSMAvol) for PSMA PET/MRI. Results: Sensitivity and specificity were 61.4% and 92.9% for mpMRI and 66.7% and 92.9% for PSMA PET/MRI for reader one, respectively. RPE was available in 23 patients and 41 of 47 quadrants with discrepant findings. Based on RPE results, the specificity for both imaging modalities increased to 98% and 99%, and the sensitivity improved to 63.9% and 72.1% for mpMRI and PSMA PET/MRI, respectively. Both modalities yielded a substantial interreader agreement for primary tumour localization (mpMRI kappa = 0.65 (0.52-0.79), PSMA PET/MRI kappa = 0.73 (0.61-0.84)). ICC for SUVmax, PSMAvol and lesion diameter were almost perfect (≥ 0.90) while for ADC it was only moderate (ICC = 0.54 (0.04-0.78)). ADC and lesion diameter did not correlate significantly with Gleason score (ρ = 0.26 and ρ = 0.16) while SUVmax and PSMAvol did (ρ = - 0.474 and ρ = - 0.468). Conclusions: PSMA PET/MRI has similar accuracy and reliability to mpMRI regarding primary prostate cancer (PCa) localization. In our cohort, semiquantitative parameters from PSMA PET/MRI correlated with tumour grade and were more reliable than the ones from mpMRI. Keywords: ADC; Biopsy guidance; Interreader agreement; PET/MRI; PSMA PET; Primary staging; SUVmax; Targeted biopsy; Template biopsy; mpMRI

    Comparison of different dosimetric methods for red marrow absorbed dose calculation in thyroid cancer therapy

    No full text
    Several dosimetric methods have been proposed for estimating red marrow absorbed dose (RMAD) when radionuclide therapy is planned for differentiated thyroid cancer, although to date, there is no consensus as to whether dose calculation should be based on blood-activity concentration or not. Our purpose was to compare RMADs derived from methods that require collecting patients' blood samples versus those involving OLINDA/EXM software, thereby precluding this invasive procedure. This is a retrospective study that included 34 patients under treatment for metastatic thyroid disease. A deviation of 10 between RMADs was found, when comparing the doses from the most usual invasive dosimetric methods and those from OLINDA/EXM. No statistical difference between the methods was discovered, whereby the need for invasive procedures when calculating the dose is questioned. The use of OLINDA/EXM in clinical routine could possibly diminish data collection, thus giving rise to a simultaneous reduction in time and clinical costs, besides avoiding any kind of discomfort on the part of the patients involved

    Contribuição da medicina nuclear para a avaliação dos linfomas

    No full text
    A medicina nuclear permite a caracterização funcional de tecidos, acrescentando dados à avaliação anatômica realizada por outros métodos de imagem, como a tomografia computadorizada, ressonância magnética ou ultra-som. Além do diagnóstico e estadiamento, as informações funcionais fornecidas pela medicina nuclear são particularmente úteis no seguimento e avaliação de resposta terapêutica dos pacientes com linfoma. A presença de massa residual após quimioterapia ou a infiltração de linfonodos de pequenas dimensões são exemplos de situações nas quais a avaliação isolada de características anatômicas é insuficiente. Os principais métodos utilizados são a cintilografia com gálio-67, traçador com alta afinidade por transferrina e receptores de ferro, e os estudos com flúor-deoxiglicose, emissor de pósitron que permite a caracterização do metabolismo de glicose nos tecidos. Outros traçadores, como o tálio-201, sestamibi-Tc99m e octreotide-In111, também são utilizados em menor escala na avaliação dos pacientes com linfoma. Os mecanismos de captação, principais indicações dos estudos, limitações e resultados de literatura serão revistos

    Etiology of congenital hypothyroidism using thyroglobulin and ultrasound combination

    No full text
    Methods currently employed to establish the etiology of congenital hypothyroidism include thyroid ultrasound and scintigraphic exams. Thyroglobulin is a protein almost exclusively secreted by thyroid tissue and indirectly reflects the amount of follicular cells. Even though thyroglobulin is easy to measure, it has been not frequently used because of discordant results to distinguish mainly athyreosis and ectopy (dysgenesis). Knowing the differences in inheritance and prognosis of thyroid dysgenesis and dyshormonogenesis, it is important to define the etiology of CH, combining tools that are easy, fast and available in most medical centers. Our objective was to evaluate and compare color Doppler ultrasound and serum thyroglobulin with radionuclide scan to define the etiology of congenital hypothyroidism. We evaluated 38 children above 3 years-old off-treatment that performed serum thyroglobulin by immunofluorometric assay, color Doppler ultrasound and radionuclide study. On color Doppler ultrasound, 11 patients had athyreosis, 5 ectopic glands, being I associated to hemiagenesis. Twenty one had topic thyroid (3 goiters, 10 normal, 8 hypoplastic). Hemiagenesis and cystic lesion were not revealed by radionuclide scan. We observed substantial agreement between color Doppler ultrasound and radionuclide scan (kappa=0.745, p<0.0001). Serum thyroglobulin in athyreosis ranged from <1.0 to 18.7 mu g/L. Patients with ectopic glands showed wider thyroglobulin range (4.5 to 123 mu g/L, median 28.4 mu g/L). Only one patient showed thyroglobulin deficiency. By using color Doppler ultrasound and serum thyroglobulin levels as valuable combined tools, we established the etiology of congenital hypothyroidism limiting excessive and harmful exams in children, like radionuclide scan.Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)[06/05800-1

    Hot needles can confirm accurate lesion sampling intraoperatively using [ 18 F]PSMA-1007 PET/CT-guided biopsy in patients with suspected prostate cancer

    Get PDF
    Purpose: Prostate-specific membrane antigen (PSMA)-targeted PET is increasingly used for staging prostate cancer (PCa) with high accuracy to detect significant PCa (sigPCa). [68 Ga]PSMA-11 PET/MRI-guided biopsy showed promising results but also persisting limitation of sampling error, due to impaired image fusion. We aimed to assess the possibility of intraoperative quantification of [18F]PSMA-1007 PET/CT uptake in core biopsies as an instant confirmation for accurate lesion sampling. Methods: In this IRB-approved, prospective, proof-of-concept study, we included five consecutive patients with suspected PCa. All underwent [18F]PSMA-1007 PET/CT scans followed by immediate PET/CT-guided and saturation template biopsy (3.1 ± 0.3 h after PET). The activity in biopsy cores was measured as counts per minute (cpm) in a gamma spectrometer. Pearson's test was used to correlate counts with histopathology (WHO/ISUP), tumor length, and membranous PSMA expression on immunohistochemistry (IHC). Results: In 43 of 113 needles, PCa was present. The mean cpm was overall significantly higher in needles with PCa (263 ± 396 cpm) compared to needles without PCa (73 ± 44 cpm, p < 0.001). In one patient with moderate PSMA uptake (SUVmax 8.7), 13 out of 24 needles had increased counts (100-200 cpm) but only signs of inflammation and PSMA expression in benign glands on IHC. Excluding this case, ROC analysis resulted in an AUC of 0.81, with an optimal cut-off to confirm PCa at 75 cpm (sens/spec of 65.1%/87%). In all 4 patients with PCa, the first or second PSMA PET-guided needle was positive for sigPCa with high counts (156-2079 cpm). Conclusions: [18F]PSMA-1007 uptake in PCa can be used to confirm accurate lesion sampling of the dominant tumor intraoperatively. This technique could improve confidence in imaging-based biopsy guidance and reduce the need for saturation biopsy. Trial registration number: NCT03187990, 15/06/2017. Keywords: Biopsy guidance; PSMA PET; Primary staging; Targeted biopsy; Template biopsy

    Diagnostic performance of 68 Ga-PSMA-11 PET/MRI-guided biopsy in patients with suspected prostate cancer: a prospective single-center study

    Get PDF
    Purpose: Ultrasound-guided biopsy (US biopsy) with 10-12 cores has a suboptimal sensitivity for clinically significant prostate cancer (sigPCa). If US biopsy is negative, magnetic resonance imaging (MRI)-guided biopsy is recommended, despite a low specificity for lesions with score 3-5 on Prostate Imaging Reporting and Data System (PIRADS). Screening and biopsy guidance using an imaging modality with high accuracy could reduce the number of unnecessary biopsies, reducing side effects. The aim of this study was to assess the performance of positron emission tomography/MRI with 68Ga-labeled prostate-specific membrane antigen (PSMA-PET/MRI) to detect and localize primary sigPCa (ISUP grade group 3 and/or cancer core length ≥ 6 mm) and guide biopsy. Methods: Prospective, open-label, single-center, non-randomized, diagnostic accuracy study including patients with suspected PCa by elevation of prostate-specific antigen (PSA) level and a suspicious lesion (PIRADS ≥3) on multiparametric MRI (mpMRI). Forty-two patients underwent PSMA-PET/MRI followed by both PSMA-PET/MRI-guided and section-based saturation template biopsy between May 2017 and February 2019. Primary outcome was the accuracy of PSMA-PET/MRI for biopsy guidance using section-based saturation template biopsy as the reference standard. Results: SigPCa was found in 62% of the patients. Patient-based sensitivity, specificity, negative and positive predictive value, and accuracy for sigPCa were 96%, 81%, 93%, 89%, and 90%, respectively. One patient had PSMA-negative sigPCa. Eight of nine false-positive lesions corresponded to cancer on prostatectomy and one in six false-negative lesions was negative on prostatectomy. Conclusion: PSMA-PET/MRI has a high accuracy for detecting sigPCa and is a promising tool to select patients with suspicion of PCa for biopsy. Trial registration: This trial was retrospectively registered under the name "Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) Guided Biopsy in Men with Elevated PSA" (NCT03187990) on 06/15/2017 ( https://clinicaltrials.gov/ct2/show/NCT03187990 ). Keywords: Imaging-guided biopsy; PET/MR; PSMA-PET accuracy; Prostate biopsy; Targeted biopsy; Template biopsy

    Does long-term creatine supplementation impair kidney function in resistance-trained individuals consuming a high-protein diet?

    No full text
    Abstract Background The aim of this study was to determine the effects of creatine supplementation on kidney function in resistance-trained individuals ingesting a high-protein diet. Methods A randomized, double-blind, placebo-controlled trial was performed. The participants were randomly allocated to receive either creatine (20 g/d for 5 d followed by 5 g/d throughout the trial) or placebo for 12 weeks. All of the participants were engaged in resistance training and consumed a high-protein diet (i.e., ≥ 1.2 g/Kg/d). Subjects were assessed at baseline (Pre) and after 12 weeks (Post). Glomerular filtration rate was measured by 51Cr-EDTA clearance. Additionally, blood samples and a 24-h urine collection were obtained for other kidney function assessments. Results No significant differences were observed for 51Cr-EDTA clearance throughout the trial (Creatine: Pre 101.42 ± 13.11, Post 108.78 ± 14.41 mL/min/1.73m2; Placebo: Pre 103.29 ± 17.64, Post 106.68 ± 16.05 mL/min/1.73m2; group x time interaction: F = 0.21, p = 0.64). Creatinine clearance, serum and urinary urea, electrolytes, proteinuria, and albuminuria remained virtually unchanged. Conclusions A 12-week creatine supplementation protocol did not affect kidney function in resistance-trained healthy individuals consuming a high-protein diet; thus reinforcing the safety of this dietary supplement. Trial registration ClinicalTrials.gov NCT0181767
    corecore