802 research outputs found

    Solid-liquid equilibria for the dimethyl ether plus carbon dioxide binary system

    Get PDF
    A recently built experimental setup was employed for the estimation of the solid-liquid equilibria of alternative refrigerants systems. The behavior of dimethyl ether (DME) + carbon dioxide was measured down to temperatures of 131.6 K. To confirm the reliability of the apparatus, the triple point of the DME was measured. The triple point data measured revealed a good consistency with the literature. The results obtained for the mixtures were corrected by the Rossini method and interpreted by means of the Schröder equation. © 2010 Akadémiai Kiadó, Budapest, Hungary

    Experimental measurement technique for the assessment of the fuel crossover diffusion coefficient in the membrane electrode assembly of a direct methanol fuel cell

    Get PDF
    Since the cross-over still seems to be the main issue of the direct methanol fuel cells, an experimental evaluation of the diffusive cross-over is performed. Even if the relationship of the rate through the membrane is the sum of the three terms of diffusive, osmotic and drag, the diffusive component is also present at open circuit lowering the Open Circuit Voltage of the single cell up to 50 % with respect to the Nernst potential. The goal of the research is to develop a direct measurement technique of the crossover that can provide the effective values of the parameters that characterize the membrane electrode assembly. The experimental set up consists in the pressure, flow and temperature control and acquisition using Labview. A sensitive analysis for three values of temperatures at 60°C, 65°C and 70°C is performed for first. Then, a small overpressure was generated in the cathode side by a valve located at the cathode outlet. A set of pressure were analysed for 0, 30 and 90 mbar of overpressure at the cathode. The tested fuel cell has a commercial Nafion 117 membrane and carbon paper gas diffusion layers 700 cm2 large. Preliminary results show that the differential concentration term seems to be significantly larger than the osmotic term. The diffusion coefficients are useful for fuel cell modelling and for the calibration of the operating conditions in the sensor less DMFC systems

    Conversion of neutral nitrogen-vacancy centers to negatively-charged nitrogen-vacancy centers through selective oxidation

    Full text link
    The conversion of neutral nitrogen-vacancy centers to negatively charged nitrogen-vacancy centers is demonstrated for centers created by ion implantation and annealing in high-purity diamond. Conversion occurs with surface exposure to an oxygen atmosphere at 465 C. The spectral properties of the charge-converted centers are investigated. Charge state control of nitrogen-vacancy centers close to the diamond surface is an important step toward the integration of these centers into devices for quantum information and magnetic sensing applications.Comment: 4 pages, 3 figure

    Devices and architectures for large scale integrated silicon photonics circuits

    Get PDF
    We present DWDM nanophotonics architectures based on microring resonator modulators and detectors. We focus on two implementations: an on chip interconnect for multicore processor (Corona) and a high radix network switch (HyperX). Based on the requirements of these applications we discuss the key constraints on the photonic circuits' devices and fabrication techniques as well as strategies to improve their performance

    Chip-based microcavities coupled to NV centers in single crystal diamond

    Full text link
    Optical coupling of nitrogen vacancy centers in single-crystal diamond to an on-chip microcavity is demonstrated. The microcavity is fabricated from a hybrid gallium phosphide and diamond material system, and supports whispering gallery mode resonances with spectrometer resolution limited Q > 25000

    Nanocavity enhanced diamond nitrogen-vacancy center zero phonon line emission

    Get PDF
    Resonantly enhanced emission of the zero phonon line of a diamond nitrogen-vacancy center in single crystal diamond is demonstrated experimentally using a hybrid whispering gallery mode nanocavity

    Coupling of Nitrogen-Vacancy Centers to Photonic Crystal Cavities in Monocrystalline Diamond

    Get PDF
    The zero-phonon transition rate of a nitrogen-vacancy center is enhanced by a factor of ~70 by coupling to a photonic crystal resonator fabricated in monocrystalline diamond using standard semiconductor fabrication techniques. Photon correlation measurements on the spectrally filtered zero-phonon line show antibunching, a signature that the collected photoluminescence is emitted primarily by a single nitrogen-vacancy center. The linewidth of the coupled nitrogen-vacancy center and the spectral diffusion are characterized using high-resolution photoluminescence and photoluminescence excitation spectroscopy
    corecore