    Glenohumeral joint motion after subscapularis tendon repair: an analysis of cadaver shoulder models

    Get PDF
    BACKGROUND: As for the surgical treatment of the rotator cuff tears, the subscapularis tendon tears have recently received much attention for the mini-open or arthroscopic repair. The results of surgical repair for the subscapularis tendon tear are satisfactory, but the range of external rotation is reported to be restricted after the repair. The purpose of this study was to evaluate the range of glenohumeral joint motion after repairs of various sizes of subscapularis tendon tears. METHODS: Using eight fresh frozen human cadaveric shoulders (mean age at death, 81.5 years), three sizes of subscapularis tendon tear (small, medium, and large) were made and then repaired. With the scapula fixed to the wooden jig, the end-range of glenohumeral motion was measured with passive movement applied through 1.0-Nm torque in the directions of scapular elevation, flexion, abduction, extension, horizontal abduction, and horizontal adduction. The passive end-ranges of external and internal rotation in various positions with rotational torque of 1.0 Nm were also measured. Differences in the ranges among the three type tears were analyzed. RESULTS: As tear size increased, range of glenohumeral motion in horizontal abduction after repair decreased gradually and was significantly decreased with the large size tear (P < 0.01). The end-range of external rotation decreased progressively with increasing tear size in every glenohumeral position. The prominent decrease in external rotation (around 40° reduction from intact shoulders) was observed in shoulders after repair of large size tear at 30° to 60° of scapular elevation and abduction. CONCLUSIONS: As the size of the subscapularis tendon tear increased, the passive ranges of horizontal abduction and external rotation of the glenohumeral joint after repair decreased significantly. In shoulders with a subscapularis tendon tear, it is necessary to consider the reduction of external rotation depending on tear size

    Semi-automatic retractable handrail utilizing opening/closing movement of sliding door supporting elderly people to walk independently

    Get PDF
    The purpose of this research is to install a handrail on the sliding doors used in hospitals and nursing facilities to support senior and people with disabilities to walk by themselves. The semi-automatic lifting equipment is utilized for the retractable handrail to make sure people in bad health are able to open the door using a weak force. To design the handrail for this purpose, the theoretical formula for opening force is derived. Then the simulation is performed with varying geometry conditions confirming the results are in good agreement with the experiment results. The opening force is designed to be less than the target value previously reported. The sliding door developed in this study is useful for elderly people walking by themselves safely.Peer Reviewe

    Diagnostic accuracy of narrow-band imaging and pit pattern analysis significantly improved for less-experienced endoscopists after an expanded training program

    Get PDF
    Background: Previous reports assessing diagnostic skill using narrow-band imaging (NBI) and pit pattern analysis for colorectal polyps involved only highly experienced endoscopists. Objective: To evaluate diagnostic skills of less-experienced endoscopists (LEE group) for. differentiation of diminutive colorectal polyps by using NBI and pit pattern analysis with and without magnification after an expanded training program. Design: Prospective study. Patients: This study involved 32 patients with 44 colorectal polyps (27 adenomas and 17 hyperplastic polyps) of 5 mm that were identified and analyzed by using conventional colonoscopy as well as non-magnification and magnification NBI and chromoendoscopy followed by endoscopic removal for histopathological analysis. Intervention: Before a training course, 220 endoscopic images were distributed in randomized order to residents with no prior endoscopy experience (NEE group) and to the LEE group, who had performed colonoscopies for more than 5 years but had never used NBI. The 220 images were also distributed to highly experienced endoscopists (HEE group) who had routinely used NBI for more than 5 years. The images were distributed to the NEE and LEE groups again after a training class. Magnification NBI and chromoendoscopy images were assessed by using the Sano and Kudo classification systems, respectively. Main Outcome Measurements: Diagnostic accuracy and interobserver agreement for each endoscopic modality in each group. Results: Diagnostic accuracy was significantly higher, and kappa (kappa) values improved in the LEE group for NBI with high magnification after expanded training. Diagnostic accuracy and kappa values when using high-magnification NBI were highest among endoscopic techniques for the LEE group after such training and the HEE group (accuracy 90% vs 93%; kappa = 0.79 vs 0.85, respectively). Limitations: Study involved only polyps of <= 5 mm. Conclusion: Using high-magnification NBI increased the differential diagnostic skill of the LEE group after expanded training so that it was equivalent to that of the HEE group

    Semi-Automatic Retractable Handrail Utilizing Opening/Closing of Sliding Door Supporting Elderly People to Walk Independently

    Get PDF
    The purpose of this research is to install a handrail on the sliding doors used in hospitals and nursing facilities to support seniors and people with disabilities to walk by themselves. The semi-automatic lifting equipment is utilized for the retractable handrail to make sure people in bad health are able to open the door using a weak force. To design the handrail for this purpose, the theoretical formula for opening force is derived. Then the simulation is performed with varying geometry conditions confirming the results are in good agreement with the experiment results. The opening force is designed to be less than the target value previously reported. The sliding door developed in this study is useful for elderly people walking by themselves safely

    Research integrity in Instructions for Authors in Japanese medical journals using ICMJE Recommendations: A descriptive literature study

    Get PDF
    Koizumi Shiho, Ide Kazuki, Becker Carl, et al. Research integrity in Instructions for Authors in Japanese medical journals using ICMJE Recommendations: A descriptive literature study. PLOS ONE 19, e0305707 (2024); https://doi.org/10.1371/journal.pone.0305707

    Principle and clinical usefulness of the infrared fluorescence endoscopy

    Get PDF
    Since there is no infrared fluorescence materials in the living body, infrared fluorescence labeling materials are very useful for making a diagnosis of a micro cancer. We have developed an infrared fluorescence endoscope (IRFE) and indocyanin green (ICG)-derivative as infrared fluorescence labeling materials to evaluate gastrointestinal neoplastic lesions. The study aims were to apply an IRFE and to demonstrate its usefulness in detecting cancerous tissue using an antibody coupled with ICG-derivative. IRFE consisted of an infrared endoscope equipped with excitation (710-790nm) and barrier (810-920nm) filters and an intensified CCD camera. We have developed ICG N-hydroxy sulfo succinimide ester (ICG-sulfo-OSu) and 3-ICG-acyl-1, 3-thiazolidine-2-thione (ICG-ATT) as an infrared fluorescent-labeling reagent. ICG-derivative-labeled mouse anti-human carcinoembryonic antigen (CEA)antibodyandMUC1 antibody were employed in this study. Moreover, we examined the ability of a reinforcement agent, octylglucoside, to intensity fluorescence from the labeled antibody. Biopsy specimens of gastric cancer were stained with anti-CEA antibody by the avidin-biotinylated peroxidase complex method. Among the positive specimens, freshly resected stomach from three cases were used for the infrared (IR) imaging analysis. The incubation of freshly resected stomach specimens with ICG-anti-CEA antibody-complex resulted in positive staining of the tumor sites by IRFE, and the IR fluorescent images correlated well with the tumor sites. The immunohistochemical studies suggested that the intensity of IR fluorescence of ICG-ATT-MUC1was stronger than that of ICG-sulfo-OSu. In tumor sections, the reinforcement agent intensified fluorescence, ever at low antibody concentrations. Therefore, we conclude that an anti-CEA (and/orMUC1) antibody with affinity for cancerous lesions and labeled with ICG-derivative can be imaged with this IRFE. Specific antibodies tagged with ICG-derivative with the reinforcement agent can label cancer cells and generate a strong enough fluorescent signal to detect small cancers when examined with an IR fluorescence endoscope

    Relationship between mucin expression and preoperative bile juice cytology in biliary tract carcinoma

    Get PDF
    The present study evaluated correlations between preoperative bile juice cytology and mucin expression of surgical specimens in biliary tract carcinoma. Twenty-five patients with biliary tract carcinoma surgically treated at our hospital, whose bile juice cytology had been evaluated before operation, were allocated to this study. Biliary cytology was classified into three categories based on the Papanicolaou classification. Immunohistochemical staining of tissues was performed using MUC1 and MUC2 monoclonal antibodies. Lesions showing MUC1 expression of ++ or higher and MUC2 expression of - were classified as Group A, and the remaining lesions as Group B. According to the epithelial site, preoperative cytology was highly correlated in Group A, while it was negative in Group B (p<0.05). In the advanced site of carcinomas, preoperative cytology tended to highly be positive in Group A, while it tended to be negative in Group B (p<0.05). These results suggest that the bile juice cytology results are affected by characteristics of mucin expression in the tissue. Based on the possibility that mucin expression correlates with the prognosis of each carcinoma, a positive cytological result suggests a poor prognosis for the carcinoma, which may be informative for predicting the post-operative courses and choosing treatments

    Optimal labeling condition of antibodies available for immunofluorescence endoscopy

    Get PDF
    Purpose: In recent years, labeled antibodies have been used for diagnostic imaging in many studies. In this study, we investigated the mode of binding in antibodies labeled with ICG derivatives newly developed for the diagnosis of microcarcinomas, and evaluated the optimal binding molar ratio between the labeling compounds and antibody. Methods: MUC1 antibody and ICG derivatives (ICG-ATT and ICG-sulfo-OSu) were used. ICG derivatives noncovalently bound to the antibody were removed with ethyl acetate, and the ratio of ICG derivatives covalently bound to the labeled antibody was confirmed. During purification of the labeled antibody, the amount of each labeling compound reacting with 1molecule of the antibody varied as follows: 4, 8, 16, and 32molar equivalents. Subsequently, the intensity of fluorescence was evaluated by spectroscopy and infrared fluoroscopy. Results : The ratio of residual ICG derivative labeling the antibody was 67.4% for ICG-ATT and 65.0% for ICG-sulfo-OSu. When fluorescent antibody labeled with ICG-ATT at anF/Pratio of 2.94or 4.18wasused, specific and clear fluorescent images of the antigen were obtained. When ICG-ATT-labeled antibody at an F/P ratio of 6.50 or 6.75 was used, the fluorescence intensity decreased and the fluorescent images of antigen became unclear. Conclusions: It was found that the ICG-ATT-labeled antibody was a more specific and sensitive marker than ICG-sulfo-OSu-labeled antibody, and that lower binding molar ratios of ICG-ATT were more useful for labeling the antibody