4,117 research outputs found
The H1 Forward Track Detector at HERA II
In order to maintain efficient tracking in the forward region of H1 after the
luminosity upgrade of the HERA machine, the H1 Forward Track Detector was also
upgraded. While much of the original software and techniques used for the HERA
I phase could be reused, the software for pattern recognition was completely
rewritten. This, along with several other improvements in hit finding and
high-level track reconstruction, are described in detail together with a
summary of the performance of the detector.Comment: Minor revision requested by journal (JINST) edito
Fiber-Cavity-Based Optomechanical Device
We describe an optomechanical device consisting of a fiber-based optical
cavity containing a silicon nitiride membrane. In comparison with typical
free-space cavities, the fiber-cavity's small mode size (10 {\mu}m waist, 80
{\mu}m length) allows the use of smaller, lighter membranes and increases the
cavity-membrane linear coupling to 3 GHz/nm and quadratic coupling to 20
GHz/nm^2. This device is also intrinsically fiber-coupled and uses glass
ferrules for passive alignment. These improvements will greatly simplify the
use of optomechanical systems, particularly in cryogenic settings. At room
temperature, we expect these devices to be able to detect the shot noise of
radiation pressure.Comment: 4 pages, 3 figures; the following article has been submitted to
Applied Physics Letter
Time-Resolved Spin Torque Switching and Enhanced Damping in Py/Cu/Py Spin-Valve Nanopillars
We report time-resolved measurements of current-induced reversal of a free
magnetic layer in Py/Cu/Py elliptical nanopillars at temperatures T = 4.2 K to
160 K. Comparison of the data to Landau-Lifshitz-Gilbert macrospin simulations
of the free layer switching yields numerical values for the spin torque and the
Gilbert damping parameters as functions of T. The damping is strongly
T-dependent, which we attribute to the antiferromagnetic pinning behavior of a
thin permalloy oxide layer around the perimeter of the free layer. This
adventitious antiferromagnetic pinning layer can have a major impact on spin
torque phenomena.Comment: 5 pages, 4 figure
Mechanisms limiting the coherence time of spontaneous magnetic oscillations driven by DC spin-polarized currents
The spin-transfer torque from a DC spin-polarized current can generate
highly-coherent magnetic precession in nanoscale magnetic-multilayer devices.
By measuring linewidths of spectra from the resulting resistance oscillations,
we argue that the coherence time can be limited at low temperature by thermal
deflections about the equilibrium magnetic trajectory, and at high temperature
by thermally-activated transitions between dynamical modes. Surprisingly, the
coherence time can be longer than predicted by simple macrospin simulations.Comment: 12 pages, 4 figure
Local origins impart conserved bone type-related differences in human osteoblast behaviour
Osteogenic behaviour of osteoblasts from trabecular, cortical and subchondral bone were examined to determine any bone type-selective differences in samples from both osteoarthritic (OA) and osteoporotic (OP) patients. Cell growth, differentiation; alkaline phosphatase (TNAP) mRNA and activity, Runt-related transcription factor-2 (RUNX2), SP7-transcription factor (SP7), bone sialoprotein-II (BSP-II), osteocalcin/bone gamma-carboxyglutamate (BGLAP), osteoprotegerin (OPG, TNFRSF11B), receptor activator of nuclear factor-κβ ligand (RANKL, TNFSF11) mRNA levels and proangiogenic vascular endothelial growth factor-A (VEGF-A) mRNA and protein release were assessed in osteoblasts from paired humeral head samples from age-matched, human OA/OP (n = 5/4) patients. Initial outgrowth and increase in cell number were significantly faster (p < 0.01) in subchondral and cortical than trabecular osteoblasts, in OA and OP, and this bone type-related differences were conserved despite consistently faster growth in OA. RUNX2/SP7 levels and TNAP mRNA and protein activity were, however, greater in trabecular than subchondral and cortical osteoblasts in OA and OP. BSP-II levels were significantly greater in trabecular and lowest in cortical osteoblasts in both OA and OP. In contrast, BGLAP levels showed divergent bone type-selective behaviour; highest in osteoblasts from subchondral origins in OA and trabecular origins in OP. We found virtually identical bone type-related differences, however, in TNFRSF11B:TNFSF11 in OA and OP, consistent with greater potential for paracrine effects on osteoclasts in trabecular osteoblasts. Subchondral osteoblasts (OA) exhibited highest VEGF-A mRNA levels and release. Our data indicate that human osteoblasts in trabecular, subchondral and cortical bone have inherent, programmed diversity, with specific bone type-related differences in growth, differentiation and pro-angiogenic potential in vitro
Strong and Tunable Nonlinear Optomechanical Coupling in a Low-Loss System
A major goal in optomechanics is to observe and control quantum behavior in a
system consisting of a mechanical resonator coupled to an optical cavity. Work
towards this goal has focused on increasing the strength of the coupling
between the mechanical and optical degrees of freedom; however, the form of
this coupling is crucial in determining which phenomena can be observed in such
a system. Here we demonstrate that avoided crossings in the spectrum of an
optical cavity containing a flexible dielectric membrane allow us to realize
several different forms of the optomechanical coupling. These include cavity
detunings that are (to lowest order) linear, quadratic, or quartic in the
membrane's displacement, and a cavity finesse that is linear in (or independent
of) the membrane's displacement. All these couplings are realized in a single
device with extremely low optical loss and can be tuned over a wide range in
situ; in particular, we find that the quadratic coupling can be increased three
orders of magnitude beyond previous devices. As a result of these advances, the
device presented here should be capable of demonstrating the quantization of
the membrane's mechanical energy.Comment: 12 pages, 4 figures, 1 tabl
Tunable linear and quadratic optomechanical coupling for a tilted membrane within an optical cavity: theory and experiment
We present an experimental study of an optomechanical system formed by a
vibrating thin semi-transparent membrane within a high-finesse optical cavity.
We show that the coupling between the optical cavity modes and the vibrational
modes of the membrane can be tuned by varying the membrane position and
orientation. In particular we demonstrate a large quadratic dispersive
optomechanical coupling in correspondence with avoided crossings between
optical cavity modes weakly coupled by scattering at the membrane surface. The
experimental results are well explained by a first order perturbation treatment
of the cavity eigenmodes.Comment: 10 pages, 6 figure
- …