4,117 research outputs found

    The H1 Forward Track Detector at HERA II

    Full text link
    In order to maintain efficient tracking in the forward region of H1 after the luminosity upgrade of the HERA machine, the H1 Forward Track Detector was also upgraded. While much of the original software and techniques used for the HERA I phase could be reused, the software for pattern recognition was completely rewritten. This, along with several other improvements in hit finding and high-level track reconstruction, are described in detail together with a summary of the performance of the detector.Comment: Minor revision requested by journal (JINST) edito

    Fiber-Cavity-Based Optomechanical Device

    Full text link
    We describe an optomechanical device consisting of a fiber-based optical cavity containing a silicon nitiride membrane. In comparison with typical free-space cavities, the fiber-cavity's small mode size (10 {\mu}m waist, 80 {\mu}m length) allows the use of smaller, lighter membranes and increases the cavity-membrane linear coupling to 3 GHz/nm and quadratic coupling to 20 GHz/nm^2. This device is also intrinsically fiber-coupled and uses glass ferrules for passive alignment. These improvements will greatly simplify the use of optomechanical systems, particularly in cryogenic settings. At room temperature, we expect these devices to be able to detect the shot noise of radiation pressure.Comment: 4 pages, 3 figures; the following article has been submitted to Applied Physics Letter

    Time-Resolved Spin Torque Switching and Enhanced Damping in Py/Cu/Py Spin-Valve Nanopillars

    Full text link
    We report time-resolved measurements of current-induced reversal of a free magnetic layer in Py/Cu/Py elliptical nanopillars at temperatures T = 4.2 K to 160 K. Comparison of the data to Landau-Lifshitz-Gilbert macrospin simulations of the free layer switching yields numerical values for the spin torque and the Gilbert damping parameters as functions of T. The damping is strongly T-dependent, which we attribute to the antiferromagnetic pinning behavior of a thin permalloy oxide layer around the perimeter of the free layer. This adventitious antiferromagnetic pinning layer can have a major impact on spin torque phenomena.Comment: 5 pages, 4 figure

    Mechanisms limiting the coherence time of spontaneous magnetic oscillations driven by DC spin-polarized currents

    Full text link
    The spin-transfer torque from a DC spin-polarized current can generate highly-coherent magnetic precession in nanoscale magnetic-multilayer devices. By measuring linewidths of spectra from the resulting resistance oscillations, we argue that the coherence time can be limited at low temperature by thermal deflections about the equilibrium magnetic trajectory, and at high temperature by thermally-activated transitions between dynamical modes. Surprisingly, the coherence time can be longer than predicted by simple macrospin simulations.Comment: 12 pages, 4 figure

    Local origins impart conserved bone type-related differences in human osteoblast behaviour

    Get PDF
    Osteogenic behaviour of osteoblasts from trabecular, cortical and subchondral bone were examined to determine any bone type-selective differences in samples from both osteoarthritic (OA) and osteoporotic (OP) patients. Cell growth, differentiation; alkaline phosphatase (TNAP) mRNA and activity, Runt-related transcription factor-2 (RUNX2), SP7-transcription factor (SP7), bone sialoprotein-II (BSP-II), osteocalcin/bone gamma-carboxyglutamate (BGLAP), osteoprotegerin (OPG, TNFRSF11B), receptor activator of nuclear factor-κβ ligand (RANKL, TNFSF11) mRNA levels and proangiogenic vascular endothelial growth factor-A (VEGF-A) mRNA and protein release were assessed in osteoblasts from paired humeral head samples from age-matched, human OA/OP (n = 5/4) patients. Initial outgrowth and increase in cell number were significantly faster (p < 0.01) in subchondral and cortical than trabecular osteoblasts, in OA and OP, and this bone type-related differences were conserved despite consistently faster growth in OA. RUNX2/SP7 levels and TNAP mRNA and protein activity were, however, greater in trabecular than subchondral and cortical osteoblasts in OA and OP. BSP-II levels were significantly greater in trabecular and lowest in cortical osteoblasts in both OA and OP. In contrast, BGLAP levels showed divergent bone type-selective behaviour; highest in osteoblasts from subchondral origins in OA and trabecular origins in OP. We found virtually identical bone type-related differences, however, in TNFRSF11B:TNFSF11 in OA and OP, consistent with greater potential for paracrine effects on osteoclasts in trabecular osteoblasts. Subchondral osteoblasts (OA) exhibited highest VEGF-A mRNA levels and release. Our data indicate that human osteoblasts in trabecular, subchondral and cortical bone have inherent, programmed diversity, with specific bone type-related differences in growth, differentiation and pro-angiogenic potential in vitro

    Strong and Tunable Nonlinear Optomechanical Coupling in a Low-Loss System

    Full text link
    A major goal in optomechanics is to observe and control quantum behavior in a system consisting of a mechanical resonator coupled to an optical cavity. Work towards this goal has focused on increasing the strength of the coupling between the mechanical and optical degrees of freedom; however, the form of this coupling is crucial in determining which phenomena can be observed in such a system. Here we demonstrate that avoided crossings in the spectrum of an optical cavity containing a flexible dielectric membrane allow us to realize several different forms of the optomechanical coupling. These include cavity detunings that are (to lowest order) linear, quadratic, or quartic in the membrane's displacement, and a cavity finesse that is linear in (or independent of) the membrane's displacement. All these couplings are realized in a single device with extremely low optical loss and can be tuned over a wide range in situ; in particular, we find that the quadratic coupling can be increased three orders of magnitude beyond previous devices. As a result of these advances, the device presented here should be capable of demonstrating the quantization of the membrane's mechanical energy.Comment: 12 pages, 4 figures, 1 tabl

    Tunable linear and quadratic optomechanical coupling for a tilted membrane within an optical cavity: theory and experiment

    Full text link
    We present an experimental study of an optomechanical system formed by a vibrating thin semi-transparent membrane within a high-finesse optical cavity. We show that the coupling between the optical cavity modes and the vibrational modes of the membrane can be tuned by varying the membrane position and orientation. In particular we demonstrate a large quadratic dispersive optomechanical coupling in correspondence with avoided crossings between optical cavity modes weakly coupled by scattering at the membrane surface. The experimental results are well explained by a first order perturbation treatment of the cavity eigenmodes.Comment: 10 pages, 6 figure
    • …
    corecore