21 research outputs found

    Procedural outcome & risk prediction in young patients undergoing transvenous lead extraction—a GALLERY subgroup analysis

    Get PDF
    BackgroundThe prevalence of young patients with cardiac implantable electronic devices (CIED) is steadily increasing, accompanied by a rise in the occurrence of complications related to CIEDs. Consequently, transvenous lead extraction (TLE) has become a crucial treatment approach for such individuals.ObjectiveThe purpose of this study was to examine the characteristics and procedural outcomes of young patients who undergo TLE, with a specific focus on identifying independent risk factors associated with adverse events.MethodsAll patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) were categorized into two groups based on their age at the time of enrollment: 45 years or younger, and over 45 years. A subgroup analysis was conducted specifically for the younger population. In this analysis, predictor variables for all-cause mortality, procedural complications, and procedural failure were evaluated using multivariable analyses.ResultsWe identified 160 patients aged 45 years or younger with a mean age of 35.3 ± 7.6 years and 42.5% (n = 68) female patients. Leading extraction indication was lead dysfunction in 51.3% of cases, followed by local infections in 20.6% and systemic infections in 16.9%. The most common device to be extracted were implantable cardioverter-defibrillators (ICD) with 52.5%. Mean number of leads per patient was 2.2 ± 1.0. Median age of the oldest indwelling lead was 91.5 [54.75–137.5] months. Overall complication rate was 3.8% with 1.9% minor and 1.9% major complications. Complete procedural success was achieved in 90.6% of cases. Clinical procedural success rate was 98.1%. Procedure-related mortality was 0.0%. The all-cause in-hospital mortality rate was 2.5%, with septic shock identified as the primary cause of mortality. Multivariable analysis revealed CKD (OR: 19.0; 95% CI: 1.84–194.9; p = 0.018) and systemic infection (OR: 12.7; 95% CI: 1.14–142.8; p = 0.039) as independent predictor for all-cause mortality. Lead age ≥ 10 years (OR: 14.58, 95% CI: 1.36–156.2; p = 0.027) was identified as sole independent risk factor for procedural complication.ConclusionTLE in young patients is safe and effective with a procedure-related mortality rate of 0.0%. CKD and systemic infection are predictors for all-cause mortality, whereas lead age ≥ 10 years was identified as independent risk factor for procedural complications in young patients undergoing TLE

    A Simplified Approach to Pulmonary Vein Visualization during Cryoballoon Ablation of Atrial Fibrillation

    No full text
    Background and Objectives: Selective pulmonary vein (PV) angiography has been established as the gold standard for PV visualization in cryoballoon (CB)-based pulmonary vein isolation (PVI). We sought to simplify this approach to reduce procedural complexity and radiation exposure. Materials and Methods: Patients with paroxysmal and recently diagnosed persistent AF undergoing CB-based PVI from January 2015 to December 2017 were retrospectively analyzed. Patients underwent either selective PV angiography or conventional left atrial (LA) angiography for PV visualization. Results: A total of 336 patients were analyzed. A total of 87 patients (26%) received PV angiography and 249 (74%) LA angiography. LA angiography required fewer cine-sequences for PV visualization, translating into a significant reduction in procedure duration, fluoroscopy time and dose area product. Additionally, less contrast medium was utilized. PV occlusion by the CB, CB temperature and time to isolation showed no significant differences. The number of CB applications and total application time (LA angiography: 1.4 ± 0.02 vs. PV Angiography: 1.6 ± 0.05; p < 0.0001; LA angiography: 297.9 ± 4.62 vs. PV-Angiography: 348.9 ± 11.03; p < 0.001, respectively) per vein were slightly but significantly higher in the PV angiography group. We observed no difference in late AF recurrence (24.7% LA angiography vs. 21.3% PV angiography; p = 0.2657). Conclusions: A simplified protocol, using LA angiography for PV visualization, entails a reduction in procedure time and radiation exposure while equally maintaining procedural efficiency and safety in both groups

    Atrial Fibrillation and Transvenous Lead Extraction—A Comprehensive Subgroup Analysis of the GermAn Laser Lead Extraction RegistrY (GALLERY)

    No full text
    Background: Atrial fibrillation is the most common arrhythmia and has been described as driver of cardiovascular morbidity and risk factor for cardiac device-related complications, as well as in transvenous lead extraction (TLE). Objectives: Aim of this study was to characterize the procedural outcome and risk-factors of patients with atrial fibrillation (AF) undergoing TLE. Methods: We performed a subgroup analysis of all AF patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) database. Predictors for all-cause mortality were assessed. Results: A total number of 510 patients with AF were identified with a mean age of 74.0 ± 10.3 years. Systemic infection (38.4%) was the leading cause for TLE, followed by local infection (37.5%) and lead dysfunction (20.4%). Most of the patients (45.9%) presented with pacemaker systems to be extracted. The total number of leads was 1181 with a 2.3 ± 0.96 leads/patient. Clinical procedural success was achieved in 97.1%. Occurrence of major complications was 1.8% with a procedure-related mortality of 1.0%. All-cause mortality was high with 5.9% and septic shock being the most common cause. Systemic device infection (OR: 49.73; 95% CI: 6.56–377.09, p < 0.001), chronic kidney disease (CKD; OR: 2.67; 95% CI: 1.01–7.03, p = 0.048) and a body mass index < 21 kg/m2 (OR: 6.6; 95% CI: 1.68–25.87, p = 0.007) were identified as independent predictors for all-cause mortality. Conclusions: TLE in AF patients is effective and safe, but in patients with systemic infection the mortality due to septic shock is high. Systemic infection, CKD and body mass index <21 kg/m2 are risk factors for death in patient with AF undergoing TLE

    Coronary Sinus Lead Removal: A Comparison between Active and Passive Fixation Leads

    No full text
    <div><p>Background</p><p>Implantation of coronary sinus (CS) leads may be a difficult procedure due to different vein anatomies and a possible lead dislodgement. The mode of CS lead fixation has changed and developed in recent years.</p><p>Objectives</p><p>We compared the removal procedures of active and passive fixation leads.</p><p>Methods</p><p>Between January 2009 and January 2014, 22 patients at our centre underwent CS lead removal, 6 active and 16 passive fixation leads were attempted using simple traction or lead locking devices with or without laser extraction sheaths. Data on procedural variables and success rates were collected and retrospectively analyzed.</p><p>Results</p><p>The mean patient age was 67.2 ± 9.8 years, and 90.9% were male. The indication for lead removal was infection in all cases. All active fixation leads were Medtronic<sup>®</sup> Attain StarFix<sup>™</sup> Model 4195 (Medtronic Inc., Minneapolis, MN, USA). The mean time from implantation for the active and passive fixation leads was 9.9 ± 11.7 months (range 1.0–30.1) and 48.7 ± 33.6 months (range 5.7–106.4), respectively (p = 0.012). Only 3 of 6 StarFix leads were successfully removed (50%) compared to 16 of 16 (100%) of the passive fixation CS leads (p = 0.013). No death or complications occurred during the 30-day follow-up.</p><p>Conclusion</p><p>According to our experience, removal of the Starfix active fixation CS leads had a higher procedural failure rate compared to passive.</p></div

    Cardiac Arrest and Successful Extracorporeal Cardiopulmonary Resuscitation as a Result of a Refeeding Syndrome in a Young Female with Anorexia Nervosa

    No full text
    Anorexia nervosa is a potentially life-threatening eating disorder, characterized by an abnormally low body weight. This case report illustrates a 22-year old female with cardiac arrest due to a refeeding syndrome in a patient with anorexia nervosa. It features the successful use of extracorporeal cardiopulmonary resuscitation in a case of severe left ventricular dysfunction resulting in a favorable outcome. Conclusion. We present the first case of a cardiac arrest due to a refeeding syndrome in anorexia nervosa featuring the successful use of an extracorporeal cardiopulmonary resuscitation approach as a bridge to full recovery
    corecore