3 research outputs found
Foramen Changes following Over Instrumentation of Curved Canals with Three Engine-Driven Instruments: An In Vitro Study
Introduction: The present in vitro study aimed to evaluate and compare the changes in shape and surface area of the major foramen following shaping of curved canals with three new generation NiTi engine-driven instruments naming ProTaper Next, BT RaCe and WaveOne Gold- with 3 different levels of protrusion beyond the major apical foramen. Methods and Materials: A total of 45 extracted human molars with at least one curved canal were distributed in 3 comparable groups of 15 that were instrumented using either ProTaper Next (PTN), BT RaCe (BTR) or WaveOne Gold (WOG). The canals were instrumented to the major foramen and then over instrumented with the final file 0.5 mm, 1 mm and 1.5 mm beyond the foramen. Standardized pre- and post-instrumentation photographs of the foramen were obtained for all groups using a stereomicroscope. Foramen shape and surface area were evaluated using the AmScope software for measurements and compared between groups and levels of instrumentation applying binary conditional logistic regression and repeated measures ANOVA. The level of significance was set at 0.05. Results: Foramen shape tended to gradually change from circular to oval as the level of instrumentation increased in all groups. The original foramen shape in WOG group remained better than other groups. Foramen surface areas increased in all groups with Group BTR demonstrating significantly greater values than the other 2 groups. Conclusion: Over instrumentation resulted in apical enlargement and ovalization in all 3 groups but with different patterns. These differences can be attributed to the final file size, design characteristics and kinematics of the 3 systems.Keywords: Apical Foramen; Curved Canals; Foramen Area; Foramen Shape; Nickel Titanium Rotary Instruments; Over Instrumentatio
Histological Study of Induced Incisions on Rabbits’ Tongues with Three Diode Lasers with Different Wavelengths in Continuous Mode
Objective. Diode lasers have multiple indications in everyday dental practice. They allow carrying out incisions, coagulation of soft tissue, and Low-Level Laser Therapy. The goal of this study is to compare histologically the tissue interaction zones and edges of an induced laser incision on rabbits’ tongues with three different wavelengths of 810, 940, and 980 nm in continuous mode. Methods. Fourteen male rabbits were divided into six groups. Each animal underwent three incisions of 10 mm length on the right ventral face of the tongue, carried out in continuous mode with three diode lasers with different wavelengths of 810, 940, and 980 nm. Rabbits were sacrificed at 0, 1, 2, 6, and 15 hours and 14 days. Five rabbits were sacrificed at 0 hours and 2 hours and one rabbit was sacrificed at 1, 6, and 15 hours and at 14 days. The appearance of neutrophils marked the onset time of the inflammatory reaction. Histological study of the incisions was chosen to evaluate the edges and to measure the depth and width of carbonization and necrotic and inflammatory zones. Healing was evaluated at 14 days. Friedman test was used to assess statistical differences between groups. Results. In the experimental adopted conditions, the carbonization zone was marked by degradation of vacuoles and an elongation of nuclei and was observed on the edges of incisions. Carbonization and necrotic and inflammatory zones were measured for rabbits sacrificed at 0, 1, 2, 6, and 15 hours but the onset of inflammation zone marked by the infiltration of neutrophils did not appear before 6 hours. The neutrophils infiltration was higher at 15 hours than at 6 hours. Complete healing was shown at 14 days. According to the time for the regularity of the edges, the interpretation was qualitative without a statistical test. The statistical analysis of the three different diode lasers in this study showed nonsignificant difference between the different groups for the depth (p=0.121) and width (p=0.376) of the incisions, the carbonization zone (p=0.692), and the necrotic zone (p=0.223). For the inflammation zone at 6 and 15 hours, statistical analysis was not carried out; only one rabbit was enough to evaluate onset of neutrophils infiltration and to compare its density for 6 and 15 hours. Conclusion. These results indicate that diode laser used in the continuous mode is predictable for induced incision. The use of three diode lasers with different wavelengths of 810, 940, and 980 nm did not reveal a significant statistical difference according to depth and width of the incision and for carbonization and necrotic zone. The appearance of neutrophils was marked between 4 and 6 hours and was higher at 15 hours