4 research outputs found
Is CRT Optimization Obsolete? A Referral Center's Experience
Background: Cardiac resynchronization therapy (CRT) is a well-established therapy for patients with heart failure (HF). However, 30% of HF patients do not show any improvement in clinical status after CRT implantation. In this study, we report our echocardiography-based CRT optimization methodology, in daily practice at our CRT referral center. Methods: We included 350 ambulatory patients, who were referred to our center for optimization after CRT implantation. A protocol-driven echocardiographic approach for adjusting mechanical dyssynchrony, whereby adjusting for ventriculoventricular (VV) delays with strain and atrioventricular (AV) delays with Doppler echocardiography was performed. We defined changes in left ventricular ejection fraction (LVEF) and New York Heart Association (NYHA) classes as outcome variables in the evaluation of the CRT outcomes. Results: Optimization was obtained in 288 (82%) patients. VV and AV timings were adjusted to 61% and 51%, respectively. In 3%, biventricular pacing was turned off and in 3% left ventricular (LV) only pacing was programmed. The LVEF and NYHA class showed significant improvements in all patients who underwent CRT optimization. Conclusions: CRT optimization remains valuable in improving LVEF and functional status measured using the NYHA class in all patients receiving CRT devices.</p
Is CRT Optimization Obsolete? A Referral Center's Experience
Background: Cardiac resynchronization therapy (CRT) is a well-established therapy for patients with heart failure (HF). However, 30% of HF patients do not show any improvement in clinical status after CRT implantation. In this study, we report our echocardiography-based CRT optimization methodology, in daily practice at our CRT referral center. Methods: We included 350 ambulatory patients, who were referred to our center for optimization after CRT implantation. A protocol-driven echocardiographic approach for adjusting mechanical dyssynchrony, whereby adjusting for ventriculoventricular (VV) delays with strain and atrioventricular (AV) delays with Doppler echocardiography was performed. We defined changes in left ventricular ejection fraction (LVEF) and New York Heart Association (NYHA) classes as outcome variables in the evaluation of the CRT outcomes. Results: Optimization was obtained in 288 (82%) patients. VV and AV timings were adjusted to 61% and 51%, respectively. In 3%, biventricular pacing was turned off and in 3% left ventricular (LV) only pacing was programmed. The LVEF and NYHA class showed significant improvements in all patients who underwent CRT optimization. Conclusions: CRT optimization remains valuable in improving LVEF and functional status measured using the NYHA class in all patients receiving CRT devices.</p
Five-year safety and efficacy of leadless pacemakers in a Dutch cohort
BACKGROUND: Adequate real-world safety and efficacy of leadless pacemakers (LPs) have been demonstrated up to 3 years after implantation. Longer-term data are warranted to assess the net clinical benefit of leadless pacing.OBJECTIVE: The purpose of this study was to evaluate the long-term safety and efficacy of LP therapy in a real-world cohort.METHODS: In this retrospective cohort study, all consecutive patients with a first LP implantation from December 21, 2012, to December 13, 2016, in 6 Dutch high-volume centers were included. The primary safety endpoint was the rate of major procedure- or device-related complications (ie, requiring surgery) at 5-year follow-up. Analyses were performed with and without Nanostim battery advisory-related complications. The primary efficacy endpoint was the percentage of patients with a pacing capture threshold ≤2.0 V at implantation and without ≥1.5-V increase at the last follow-up visit.RESULTS: A total of 179 patients were included (mean age 79 ± 9 years), 93 (52%) with a Nanostim and 86 (48%) with a Micra VR LP. Mean follow-up duration was 44 ± 26 months. Forty-one major complications occurred, of which 7 were not advisory related. The 5-year major complication rate was 4% without advisory-related complications and 27% including advisory-related complications. No advisory-related major complications occurred a median 10 days (range 0-88 days) postimplantation. The pacing capture threshold was low in 163 of 167 patients (98%) and stable in 157 of 160 (98%).CONCLUSION: The long-term major complication rate without advisory-related complications was low with LPs. No complications occurred after the acute phase and no infections occurred, which may be a specific benefit of LPs. The performance was adequate with a stable pacing capture threshold.</p
Is CRT Optimization Obsolete? A Referral Center’s Experience
Background: Cardiac resynchronization therapy (CRT) is a well-established therapy for patients with heart failure (HF). However, 30% of HF patients do not show any improvement in clinical status after CRT implantation. In this study, we report our echocardiography-based CRT optimization methodology, in daily practice at our CRT referral center. Methods: We included 350 ambulatory patients, who were referred to our center for optimization after CRT implantation. A protocol-driven echocardiographic approach for adjusting mechanical dyssynchrony, whereby adjusting for ventriculoventricular (VV) delays with strain and atrioventricular (AV) delays with Doppler echocardiography was performed. We defined changes in left ventricular ejection fraction (LVEF) and New York Heart Association (NYHA) classes as outcome variables in the evaluation of the CRT outcomes. Results: Optimization was obtained in 288 (82%) patients. VV and AV timings were adjusted to 61% and 51%, respectively. In 3%, biventricular pacing was turned off and in 3% left ventricular (LV) only pacing was programmed. The LVEF and NYHA class showed significant improvements in all patients who underwent CRT optimization. Conclusions: CRT optimization remains valuable in improving LVEF and functional status measured using the NYHA class in all patients receiving CRT devices