17 research outputs found

    Reduction in the QRS area after cardiac resynchronization therapy is associated with survival and echocardiographic response

    Get PDF
    Introduction Recent studies have shown that the baseline QRS area is associated with the clinical response after cardiac resynchronization therapy (CRT). In this study, we investigated the association of QRS area reduction ( increment QRS area) after CRT with the outcome. We hypothesize that a larger increment QRS area is associated with a better survival and echocardiographic response. Methods and Results Electrocardiograms (ECG) obtained before and 2-12 months after CRT from 1299 patients in a multi-center CRT-registry were analyzed. The QRS area was calculated from vectorcardiograms that were synthesized from 12-lead ECGs. The primary endpoint was a combination of all-cause mortality, heart transplantation, and left ventricular (LV) assist device implantation. The secondary endpoint was the echocardiographic response, defined as LV end-systolic volume reduction >= of 15%. Patients with increment QRS area above the optimal cut-off value (62 mu Vs) had a lower risk of reaching the primary endpoint (hazard ratio: 0.43; confidence interval [CI] 0.33-0.56, p = 109 mu Vs, survival, and echocardiographic response were better when the increment QRS area was >= 62 mu Vs (p = 109 mu Vs, increment QRS area was the only significant predictor of survival (OR: 0.981; CI: 0.967-0.994, p = .006). Conclusion increment QRS area is an independent determinant of CRT response, especially in patients with a large baseline QRS area. Failure to achieve a large QRS area reduction with CRT is associated with a poor clinical outcome

    Heart Size Corrected Electrical Dyssynchrony and Its Impact on Sex-specific Response to Cardiac Resynchronization Therapy

    Get PDF
    Background - Women are less likely to receive cardiac resynchronization therapy (CRT), yet, they are more responsive to the therapy and respond at shorter QRS duration. The present study hypothesized that a relatively larger left ventricular (LV) electrical dyssynchrony in smaller hearts contributes to the better CRT response in women. For this the vectorcardiography-derived QRS area is used, since it allows for a more detailed quantification of electrical dyssynchrony compared to conventional electrocardiographic markers. Methods - Data from a multicenter registry of 725 CRT patients (median follow-up: 4.2 years [IQR: 2.7-6.1]) were analyzed. Baseline electrical dyssynchrony was evaluated using the QRS area, and the corrected QRS area for heart size using the LV end-diastolic volume (QRSarea/LVEDV). Impact of the QRSarea/LVEDV-ratio on the association between sex and LV reverse remodeling (end-systolic volume change: ΔLVESV) and sex and the composite outcome of all-cause mortality, LV assist device implantation or heart transplantation was assessed. Results - At baseline, women (n=228) displayed larger electrical dyssynchrony than men (QRS area: 132±55μVs vs 123±58μVs, p=0.043) which was, even more pronounced for the QRSarea/LVEDV-ratio (0.76±0.46μVs/ml vs 0.57±0.34μVs/ml, p<0.001). After multivariable analyses female sex was associated with ΔLVESV (β 0.12, p=0.003) and a lower occurrence the composite outcome (HR 0.59 (0.42-0.85), p=0.004). A part of the female advantage regarding reverse remodeling was attributed to the larger QRSarea/LVEDV-ratio in women (25-fold change in Beta from 0.12 to 0.09). The larger QRSarea/LVEDV-ratio did not contribute to the better survival observed in women. In both volumetric responders and non-responders, female sex remained strongly associated with a lower risk of the composite outcome (adjusted HR 0.59 (0.36-0.97), p=0.036 and 0.55 (0.33-0.90), p=0.018, respectively). Conclusions - Greater electrical dyssynchrony in smaller hearts contributes in part to more reverse remodeling observed in women after CRT, but this does not explain their better long-term outcomes

    Diagnosis of allergy against beta-lactams in primary care : prevalence and diagnostic criteria

    No full text
    BACKGROUND: Secondary care studies showed that a recorded allergy to beta-lactams could not be confirmed by valid allergy testing in >85% of cases. In daily practice, recorded beta-lactam allergies probably cause prescription of secondary choice antibiotics. This overrating of beta-lactam allergy hampers appropriate use of narrow spectrum antibiotic and generates unnecessary cost and bacterial resistance. OBJECTIVE: To assess registration and over diagnosis of allergies against beta-lactams in Dutch primary care. METHODS: A retrospective cohort study in 8288 primary care subjects was performed. Patients with recorded allergy were identified through International Classification for Primary Care coding. Signs and symptoms of the recorded allergic reaction and patient's characteristics were extracted from patient's files and patients were sent a questionnaire. The probability of allergy was based on a composite reference standard that was scored by two authors independently. RESULTS: One hundred sixty-three subjects had a recorded allergy (2.0%). In 51.5% of cases, no characteristics of the recorded allergic reaction were reported in patients' medical files. Based on our composite reference standard, allergy was excluded in 19 subjects (11.7%). Risk factors for allergy registration were female gender, age <4 years, and the comorbidities-asthma, allergies and skin disorders. CONCLUSIONS: The prevalence of recorded allergy against beta-lactam antibiotics in a large Dutch primary care centre was 2%. Due to lack of registration of accompanying signs and symptoms of the recorded allergy, this diagnosis is uncertain in most patients. Better documentation and classification by a screening algorithm of future possible allergic reactions to beta-lactams are needed in primary care

    Atrioventricular optimization in cardiac resynchronization therapy with quadripolar leads: should we optimize every pacing configuration including multi-point pacing?

    No full text
    Aims: This study aims to define an atrioventricular (AV) delay optimization method for cardiac resynchronization therapy (CRT) with a quadripolar left ventricular (LV) lead based on intrinsic conduction intervals. Methods and results: Heart failure patients with a left bundle branch block underwent CRT implantation with a quadripolar LV lead. Invasive LV pressure-volume loops were recorded during four biventricular and three multi-point pacing (MPP) settings, using four patient-specific paced AV delays. Haemodynamic response was defined as change in stroke work (Δ%SW) compared to intrinsic rhythm and was related to the following conduction intervals: right atrial pacing to right ventricular sensing interval (RAp-RVs), Q to LV sensing interval normalized to QRS duration (QLV/QRSd), PR-interval, and P-wave duration. In 44 patients, the largest Δ%SW (104 ± 76%) occurred at a paced AV delay of 128 ± 32 ms, at 47 ± 9% of RAp-RVs. Optimal AV delay of biventricular pacing (126 ± 26 ms) did not differ from MPP (126 ± 21 ms, P = 0.29). Intra-class correlation coefficient between optimal AV delays of different pacing configurations was 0.64 (0.45-0.78, P < 0.001). Although not statistically significant, Δ%SW at 50% of RAp-RVs (98 ± 74%) was closer to the maximal achievable Δ%SW increase than a fixed interval of 120 ms (96 ± 73%, P = 0.60). RAp-RVs, QLV/QRSd, PR interval, and P-wave duration were associated with the optimal AV delay in univariate analysis, but only RAp-RVs remained significantly associated in multivariate analysis (R = 0.69). Conclusion: The AV delay that provides highest haemodynamic response is similar for various LV pacing configurations and for MPP. An AV delay ∼50% of RAp-RVs creates an acute haemodynamic response close to the maximal patient-specific response

    Heart Size Corrected Electrical Dyssynchrony and Its Impact on Sex-Specific Response to Cardiac Resynchronization Therapy

    No full text
    Background: Women are less likely to receive cardiac resynchronization therapy, yet, they are more responsive to the therapy and respond at shorter QRS duration. The present study hypothesized that a relatively larger left ventricular (LV) electrical dyssynchrony in smaller hearts contributes to the better cardiac resynchronization therapy response in women. For this, the vectorcardiography-derived QRS area is used, since it allows for a more detailed quantification of electrical dyssynchrony compared with conventional electrocardiographic markers. Methods: Data from a multicenter registry of 725 cardiac resynchronization therapy patients (median follow-up, 4.2 years [interquartile range, 2.7-6.1]) were analyzed. Baseline electrical dyssynchrony was evaluated using the QRS area and the corrected QRS area for heart size using the LV end-diastolic volume (QRSarea/LVEDV). Impact of the QRSarea/LVEDV ratio on the association between sex and LV reverse remodeling (LV end-systolic volume change) and sex and the composite outcome of all-cause mortality, LV assist device implantation, or heart transplantation was assessed. Results: At baseline, women (n=228) displayed larger electrical dyssynchrony than men (QRS area, 132 +/- 55 versus 123 +/- 58 mu Vs; P=0.043), which was even more pronounced for the QRSarea/LVEDV ratio (0.76 +/- 0.46 versus 0.57 +/- 0.34 mu Vs/mL; P Conclusions: Greater electrical dyssynchrony in smaller hearts contributes, in part, to more reverse remodeling observed in women after cardiac resynchronization therapy, but this does not explain their better long-term outcomes

    Pressure-Volume Loop Analysis of Multipoint Pacing With a Quadripolar Left Ventricular Lead in Cardiac Resynchronization Therapy

    No full text
    OBJECTIVES: This study aimed to compare multipoint pacing (MPP) to optimal biventricular pacing with a quadripolar left ventricular (LV) lead and find factors associated with hemodynamic response to MPP. BACKGROUND: MPP with a quadripolar LV lead may increase response to cardiac resynchronization therapy. METHODS: Heart failure patients with a left bundle branch block underwent cardiac resynchronization therapy implantation. Q to LV sensing interval divided by the intrinsic QRS duration was measured. Invasive pressure-volume loops were assessed during 4 biventricular pacing settings and 3 MPP settings, using 4 atrioventricular delays. Hemodynamic response was defined as change in stroke work (Δ%SW) compared with baseline measurements during intrinsic conduction. Δ%SW of MPP was compared with conventional biventricular pacing using the distal electrode and the electrode with highest Δ%SW (BIV-OPT). RESULTS: Forty-three patients were analyzed (age 66 ± 10 years, 63% men, 30% ischemic cardiomyopathy, LV ejection fraction 29 ± 8%, and QRS duration 175 ± 13 ms). Q to local LV sensing interval corrected for QRS duration was 84 ± 8%, and variation between LV electrodes was 9 ± 5%. Compared with conventional biventricular pacing using the distal electrode, MPP showed a significant higher increase of SW (Δ%SW +15 ± 35%; p < 0.05) with a large interindividual variation. There was no significant difference in Δ%SW with MPP compared with BIV-OPT (-5 ± 24%; p = 0.19). Male sex and low LV ejection fraction were associated with increase in Δ%SW due to MPP versus BIV-OPT in multivariate analysis, while ischemic cardiomyopathy was only associated in univariate analysis. CONCLUSIONS: Optimization of the pacing site of a quadripolar LV lead is more important than to program MPP. However, specific subgroups (i.e., especially men) may benefit substantially from MPP

    Pressure-Volume Loop Analysis of Multipoint Pacing With a Quadripolar Left Ventricular Lead in Cardiac Resynchronization Therapy

    No full text
    OBJECTIVES: This study aimed to compare multipoint pacing (MPP) to optimal biventricular pacing with a quadripolar left ventricular (LV) lead and find factors associated with hemodynamic response to MPP. BACKGROUND: MPP with a quadripolar LV lead may increase response to cardiac resynchronization therapy. METHODS: Heart failure patients with a left bundle branch block underwent cardiac resynchronization therapy implantation. Q to LV sensing interval divided by the intrinsic QRS duration was measured. Invasive pressure-volume loops were assessed during 4 biventricular pacing settings and 3 MPP settings, using 4 atrioventricular delays. Hemodynamic response was defined as change in stroke work (Δ%SW) compared with baseline measurements during intrinsic conduction. Δ%SW of MPP was compared with conventional biventricular pacing using the distal electrode and the electrode with highest Δ%SW (BIV-OPT). RESULTS: Forty-three patients were analyzed (age 66 ± 10 years, 63% men, 30% ischemic cardiomyopathy, LV ejection fraction 29 ± 8%, and QRS duration 175 ± 13 ms). Q to local LV sensing interval corrected for QRS duration was 84 ± 8%, and variation between LV electrodes was 9 ± 5%. Compared with conventional biventricular pacing using the distal electrode, MPP showed a significant higher increase of SW (Δ%SW +15 ± 35%; p < 0.05) with a large interindividual variation. There was no significant difference in Δ%SW with MPP compared with BIV-OPT (-5 ± 24%; p = 0.19). Male sex and low LV ejection fraction were associated with increase in Δ%SW due to MPP versus BIV-OPT in multivariate analysis, while ischemic cardiomyopathy was only associated in univariate analysis. CONCLUSIONS: Optimization of the pacing site of a quadripolar LV lead is more important than to program MPP. However, specific subgroups (i.e., especially men) may benefit substantially from MPP

    The value of septal rebound stretch analysis for the prediction of volumetric response to cardiac resynchronization therapy

    No full text
    Aims Patient selection for cardiac resynchronization therapy (CRT) may be enhanced by evaluation of systolic myocardial stretching. We evaluate whether systolic septal rebound stretch (SRSsept) derived from speckle tracking echocardiography is a predictor of reverse remodelling after CRT and whether it holds additive predictive value over the simpler visual dyssynchrony assessment by apical rocking (ApRock). Methods and results The association between SRSsept and change in left ventricular end-systolic volume (Delta LVESV) at 6 months of follow-up was assessed in 200 patients. Subsequently, the additive predictive value of SRSsept over the assessment of ApRock was evaluated in patients with and without left bundle branch block (LBBB) according to strict criteria. SRSsept was independently associated with Delta LVESV (beta 0.221, P = 0.002) after correction for sex, age, ischaemic cardiomyopathy, QRS morphology and duration, and ApRock. A high SRSsept (>= optimal cut-off value 2.4) also coincided with more volumetric responders (Delta LVESV >= -15%) than low SRSsept in the entire cohort (70.0% and 56.4%), in patients with strict LBBB (83.3% vs. 56.7%, P = 0.024), and non-LBBB (70.7% vs. 46.3%, P = 0.004). Moreover, in non-LBBB patients, SRSsept held additional predictive information over the assessment of ApRock alone since patients that showed ApRock and high SRSsept were more often volumetric responder than those with ApRock but low SRSsept (82.8% vs. 47.4%, P = 0.001). Conclusion SRSsept is strongly associated with CRT-induced reduction in left ventricular end-systolic volume and holds additive prognostic information over QRS morphology and ApRock. Our data suggest that CRT patient selection may be improved by assessment of SRSsept, especially in the important subgroup without strict LBBB

    The value of septal rebound stretch analysis for the prediction of volumetric response to cardiac resynchronization therapy

    Get PDF
    AIMS: Patient selection for cardiac resynchronization therapy (CRT) may be enhanced by evaluation of systolic myocardial stretching. We evaluate whether systolic septal rebound stretch (SRSsept) derived from speckle tracking echocardiography is a predictor of reverse remodelling after CRT and whether it holds additive predictive value over the simpler visual dyssynchrony assessment by apical rocking (ApRock). METHODS AND RESULTS: The association between SRSsept and change in left ventricular end-systolic volume (ΔLVESV) at 6 months of follow-up was assessed in 200 patients. Subsequently, the additive predictive value of SRSsept over the assessment of ApRock was evaluated in patients with and without left bundle branch block (LBBB) according to strict criteria. SRSsept was independently associated with ΔLVESV (β 0.221, P = 0.002) after correction for sex, age, ischaemic cardiomyopathy, QRS morphology and duration, and ApRock. A high SRSsept (≥optimal cut-off value 2.4) also coincided with more volumetric responders (ΔLVESV ≥ -15%) than low SRSsept in the entire cohort (70.0% and 56.4%), in patients with strict LBBB (83.3% vs. 56.7%, P = 0.024), and non-LBBB (70.7% vs. 46.3%, P = 0.004). Moreover, in non-LBBB patients, SRSsept held additional predictive information over the assessment of ApRock alone since patients that showed ApRock and high SRSsept were more often volumetric responder than those with ApRock but low SRSsept (82.8% vs. 47.4%, P = 0.001). CONCLUSION: SRSsept is strongly associated with CRT-induced reduction in left ventricular end-systolic volume and holds additive prognostic information over QRS morphology and ApRock. Our data suggest that CRT patient selection may be improved by assessment of SRSsept, especially in the important subgroup without strict LBBB. CLINICAL TRIAL REGISTRATION: The MARC study was registered at clinicaltrials.gov: NCT01519908

    Hemodynamic Optimization in Cardiac Resynchronization Therapy : Should We Aim for dP/dtmax or Stroke Work?

    Get PDF
    Objectives: This study evaluated the acute effect of dP/dt max- versus stroke work (SW)-guided cardiac resynchronization therapy (CRT) optimization and the related acute hemodynamic changes to long-term CRT response. Background: Hemodynamic optimization may increase benefit from CRT. Typically, maximal left ventricular (LV) pressure rise dP/dt max is used as an index of ventricular performance. Alternatively, SW can be derived from pressure−volume (PV) loops. Methods: Forty-one patients underwent CRT implantation followed by invasive PV loop measurements. The stimulation protocol included 16 LV pacing configurations using each individual electrode of the quadripolar lead with 4 atrioventricular (AV) delays. Conventional CRT was defined as pacing from the distal electrode with an AV delay of approximately 120 ms. Results: Compared with conventional CRT, dP/dt max-guided optimization resulted in a one-third additional dP/dt max increase (17 ± 11% vs. 12 ± 9%; p < 0.001). Similarly, SW-guided optimization resulted in a one-third additional SW increase (80 ± 55% vs. 53 ± 48%; p < 0.001). Comparing both optimization strategies, dP/dt max favored contractility (8 ± 12% vs. 5 ± 10%; p = 0.015), whereas SW optimization improved ventricular−arterial (VA) coupling (45% vs. 32%; p < 0.001). After 6 months, mean LV ejection fraction (LVEF) change was 10 ± 9% with 23 (56%) patients becoming super-responders to CRT (≥10% LVEF improvement). Although acute changes in SW were predictive for long-term CRT response (area under the curve: 0.78; p = 0.002), changes in dP/dt max were not (area under the curve: 0.65; p = 0.112). Conclusions: PV-guided hemodynamic optimization in CRT results in approximately one-third SW improvement on top of conventional CRT, caused by a mechanism of enhanced VA coupling. In contrast, dP/dt max optimization favored LV contractility. Ultimately, acute changes in SW showed larger predictive value for long-term CRT response compared with dP/dt max