14 research outputs found

    Application of terahertz spectroscopy to the characterization of biological samples using birefringence silicon grating

    Get PDF
    We present a device and method for performing vector transmission spectroscopy on biological specimens at terahertz (THz) frequencies. The device consists of artificial dielectric birefringence obtained from silicon microfluidic grating structures. The device can measure the complex dielectric function of a liquid, across a wide THz band of 2 to 5.5 THz, using a Fourier transform infrared spectrometer. Measurement data from a range of liquid specimens, including sucrose, salmon deoxyribonucleic acid (DNA), herring DNA, and bovine serum albumin protein solution in water are presented. The specimen handling is simple, using a microfluidic channel. The transmission through the device is improved significantly and thus the measurement accuracy and bandwidth are increase

    A terahertz polarization insensitive dual band metamaterial absorber

    Get PDF
    Metamaterial absorbers have attracted considerable attention for applications in the terahertz range. In this Letter, we report the design, fabrication, and characterization of a terahertz dual band metamaterial absorber that shows two distinct absorption peaks with high absorption. By manipulating the periodic patterned structures as well as the dielectric layer thickness of the metal–dielectric–metal structure, significantly high absorption can be obtained at specific resonance frequencies. Finite-difference time-domain modeling is used to design the structure of the absorber. The fabricated devices have been characterized using a Fourier transform IR spectrometer. The experimental results show two distinct absorption peaks at 2.7 and 5.2 THz, which are in good agreement with the simulation. The absorption magnitudes at 2.7 and 5.2 THz are 0.68 and 0.74, respectively

    A low-noise transimpedance amplifier for BLM-based ion channel recording

    Get PDF
    High-throughput screening (HTS) using ion channel recording is a powerful drug discovery technique in pharmacology. Ion channel recording with planar bilayer lipid membranes (BLM) is scalable and has very high sensitivity. A HTS system based on BLM ion channel recording faces three main challenges: (i) design of scalable microfluidic devices; (ii) design of compact ultra-low-noise transimpedance amplifiers able to detect currents in the pA range with bandwidth >10 kHz; (iii) design of compact, robust and scalable systems that integrate these two elements. This paper presents a low-noise transimpedance amplifier with integrated A/D conversion realized in CMOS 0.35 µm technology. The CMOS amplifier acquires currents in the range ±200 pA and ±20 nA, with 100 kHz bandwidth while dissipating 41 mW. An integrated digital offset compensation loop balances any voltage offsets from Ag/AgCl electrodes. The measured open-input input-referred noise current is as low as 4 fA/Root Hz at ±200 pA range. The current amplifier is embedded in an integrated platform, together with a microfluidic device, for current recording from ion channels. Gramicidin-A, alpha-haemolysin and KcsA potassium channels have been used to prove both the platform and the current-to-digital converter

    Characterization of the Prokaryotic Sodium Channel NavSp Pore with a Microfluidic Bilayer Platform

    Get PDF
    This paper describes the use of a newly-developed micro-chip bilayer platform to examine the electrophysiological properties of the prokaryotic voltage-gated sodium channel pore (NavSp) from Silicibacter pomeroyi. The platform allows up to 6 bilayers to be analysed simultaneously. Proteoliposomes were incorporated into suspended lipid bilayers formed within the microfluidic bilayer chips. The chips provide access to bilayers from either side, enabling the fast and controlled titration of compounds. Dose-dependent modulation of the opening probability by the channel blocking drug nifedipine was measured and its IC50 determined

    A distributed amplifier system for bilayer lipid membrane (BLM) arrays with noise and individual offset cancellation

    No full text
    Lipid bilayer membrane (BLM) arrays are required for high throughput analysis, for example drug screening or advanced DNA sequencing. Complex microfluidic devices are being developed but these are restricted in terms of array size and structure or have integrated electronic sensing with limited noise performance. We present a compact and scalable multichannel electrophysiology platform based on a hybrid approach that combines integrated state-of-the-art microelectronics with low-cost disposable fluidics providing a platform for high-quality parallel single ion channel recording. Specifically, we have developed a new integrated circuit amplifier based on a novel noise cancellation scheme that eliminates flicker noise derived from devices under test and amplifiers. The system is demonstrated through the simultaneous recording of ion channel activity from eight bilayer membranes. The platform is scalable and could be extended to much larger array sizes, limited only by electronic data decimation and communication capabilities

    Scaleable micro-cavity bilayer lipid membrane array for parallel ion channel recording

    No full text
    A compact, scalable and high-throughput bilayer ion channel recording platform capable of simultaneous data acquisition from multiple bilayers is presented. Microfluidic chips house micro-cavities over which bilayers are made; each connected to a custom-made compact electronic readout circuit based on ASICs (Application-Specific Integrated Circuits). The micro-cavities are fabricated using a simple dry-film resist process on a glass wafer. Single 15 mm × 15 mm glass chips contain four separately addressable bilayers, each with integrated Ag/AgCl electrodes. The number of bilayers is scaled by increasing the number of ASICs and four-cavity chips. Each chip can be cleaned and re-used many times and the cavity-suspended lipid bilayers are stable for up to 10 days. System performance is demonstrated with simultaneous electrical recordings of the ion channels gramicidin A and alpha-hemolysin in multiple bilayers

    Terahertz Systems and Technology

    No full text
    No abstract available

    Autokorrelation in oekonometrischen Modellen. Einige Anmerkungen

    No full text
    Bibliothek Weltwirtschaft Kiel C 135,530 / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEDEGerman
    corecore