178 research outputs found

    Refining the Approach to Renal Artery Revascularization

    Get PDF
    Renal artery stenosis (RAS) is caused by a heterogenous group of diseases with different pathophysiology, clinical manifestations, treatment approaches, and outcomes. The 2 most common forms of RAS are fibromuscular dysplasia (FMD) and atherosclerosis (ARAS). Renovascular syndromes are broadly classified into renovascular hypertension and ischemic nephropathy, but these terms are misleading, because they imply a causal relationship between RAS, hypertension, and renal dysfunction, which is difficult to prove in humans. Data supporting renal revascularization are limited by heterogeneous causes of hypertension and renal dysfunction, insufficient understanding of the relationship between RAS and nephropathy, inconsistent techniques for revascularization, ambiguous terminology and end points to assess benefit, and lack of large-scale randomized trials. The purpose of this review is to enhance understanding of the epidemiology, clinical markers, and diagnosis of RAS; the relationship between RAS and important disease states; the distinction between renal ischemia and nephropathy; optimal revascularization techniques; and avoidance of renal injury

    Comparative results of transluminal extraction coronary atherectomy in saphenous vein graft lesions with and without thrombus

    Get PDF
    AbstractObjectives. The purpose of this retrospective study was to compare the results of transluminal extraction coronary atherectomy in saphenous vein graft lesions with and without angiographic thrombus.Background. Percutaneous interventions in lesions with thrombus are associated with reduced procedural success and increased risk of complications. Use of the transluminal extraction catheter, which cuts and aspirates atheroma and thrombus, has been advocated as a potential revascularization strategy for lesions with thrombus.Methods. Baseline patient characteristics, lesion morphology, immediate angiographic results, in-hospital complications and follow-up were prospectively entered into an interventional cardiology data base. The results of transluminal extraction coronary atherectomy in saphenous vein bypass grafts with angiographic thrombus were compared with results in similar grafts without angiographic thrombus.Results. Transluminal extraction coronary atherectomy was performed in 175 patients with 183 vein graft lesions, including 59 lesions (32%) with thrombus (Group 1) and 124 (68%) without thrombus (Group 2). Compared with lesions in Group 2, lesions in Group 1 were associated with a higher incidence of baseline total occlusion, diffuse disease and abnormal Thrombolysis in Myocardial Infarction (TIMI) grade flow (p < 0.05); more severe diameter stenosis at baseline, after atherectomy and after final angiography (p < 0.05); a lower rate of clinical success (69% vs, 88%, p < 0.01); and more angiographic and clinical complications, including no reflow (p < 0.05), vascular repair (p < 0.05) and Q wave myocardial infarction (p = 0.09).Conclusions. In transluminal extraction coronary atherectomy of saphenous vein bypass grafts, the presence of thrombus is associated with more baseline lesion complexity, reduced clinical success and increased risk of no reflow, Q wave myocardial infarction and vascular repair

    Balloon dilation of mitral stenosis in adult patients: Postmortem and percutaneous mitral valvuloplasty studies

    Get PDF
    Preliminary reports have documented the utility of percutaneous balloon valvuloplasty of the mitral valve in adult patients with mitral stenosis, but the mechanism of successful valve dilation and the effect of mitral valvuloplasty on cardiac performance have not been studied in detail. Accordingly, mitral valvuloplasty was performed in five postmortem specimens and in 18 adult patients with rheumatic mitral stenosis, using either one (25 mm) or two (18 and 20 mm) dilation balloons. Postmortem balloon dilation resulted in increased valve orifice area in all five postmortem specimens, secondary to separation of fused commissures and fracture of nodular calcium within the mitral leaflets. In no case did balloon dilation result in tearing of valve leaflets, disruption of the mitral ring or liberation of potentially embolic debris.Percutaneous mitral valvuloplasty in 18 patients with severe mitral stenosis (including 9 with a heavily calcified valve) resulted in an increase in cardiac output (4.3 ± 1.1 to 5.1 ± 1.5 liters/min, p < 0.01) and mitral valve area (0.9 ± 0.2 to 1.6 ± 0.4 cm2, p < 0.0001), and a decrease in mean mitral pressure gradient (15 ± 5 to 9 ± 4 mm Hg, p < 0.0001), pulmonary capillary wedge pressure (23 ± 7 to 18 ± 7 mm Hg, p < 0.0001) and mean pulmonary artery pressure (36 ± 12 to 33 ± 12 mm Hg, p < 0.01). Left ventriculography before and after valvuloplasty in 14 of the 18 patients showed a mild (≀1 +) increase in mitral regurgitation in five patients and no change in the remainder. Embolic phenomena were not observed in any patient.Serial radionuclide ventriculography showed an increase in left ventricular peak filling rate (2.20 ± 1.20 to 2.50 ± 1.20 end-diastolic volumes per second [EDV/s], p < 0.05). Serial echocardiography/phonocardiography showed improvement in mitral valve excursion (11 ± 6 to 14 ± 6 mm, p < 0.001), mitral EF slope (7 ± 4 to 13 ± 5, p < 0.001), left atrial diameter (5.7 ± 0.9 to 5.3 ± 0.8 cm, p < 0.001), S2-opening snap interval (0.07 ± 0.03 to 0.08 ± 0.02 second, p < 0.02) and mitral valve area (0.9 ± 0.2 to 1.5 ± 0.4 cm2, p < 0.0001). All patients were discharged from the hospital with de- creased symptoms after valvuloplasty.It is concluded that percutaneous mitral valvuloplasty can be performed in adult patients with mitral stenosis, including patients with calcific disease, and can result in significant improvement in valvular function. The mechanisms of successful dilation include commissural separation and fracture of nodular calcium

    Oscillons: Resonant Configurations During Bubble Collapse

    Get PDF
    Oscillons are localized, non-singular, time-dependent, spherically-symmetric solutions of nonlinear scalar field theories which, although unstable, are extremely long-lived. We show that they naturally appear during the collapse of subcritical bubbles in models with symmetric and asymmetric double-well potentials. By a combination of analytical and numerical work we explain several of their properties, including the conditions for their existence, their longevity, and their final demise. We discuss several contexts in which we expect oscillons to be relevant. In particular, their nucleation during cosmological phase transitions may have wide-ranging consequences.Comment: 31 pages Revtex, 20 uufiles-encoded figures. Section "Possible Applications of Oscillons" slightly expande

    Solitonic supersymmetry restoration

    Full text link
    Q-balls are a possible feature of any model with a conserved, global U(1) symmetry and no massless, charged scalars. It is shown that for a broad class of models of metastable supersymmetry breaking they are extremely influential on the vacuum lifetime and make seemingly viable vacua catastrophically short lived. A net charge asymmetry is not required as there is often a significant range of parameter space where statistical fluctuations alone are sufficient. This effect is examined for two supersymmetry breaking scenarios. It is found that models of minimal gauge mediation (which necessarily have a messenger number U(1)) undergo a rapid, supersymmetry restoring phase transition unless the messenger mass is greater than 10^8 GeV. Similarly the ISS model, in the context of direct mediation, quickly decays unless the perturbative superpotential coupling is greater than the Standard Model gauge couplings.Comment: 17 pages, 3 figures, minor comments added, accepted for publication in JHE

    A comparison of Power Doppler with conventional sonographic imaging for the evaluation of renal artery stenosis

    Get PDF
    BACKGROUND: Power Doppler (PD) has improved diagnostic capabilities of vascular sonography, mainly because it is independent from the angle of insonation. We evaluated this technique in a prospective comparison with conventional imaging, consisting in Duplex and Color Doppler, for the evaluation of Renal Artery (RA) stenosis. METHODS: Sensitivity, specificity and predictive values of PD and conventional imaging were assessed in a blinded fashion on eighteen patients, 9 with angiographic evidence of unilateral RA stenosis (hypertensive patients) and 9 with angiographically normal arteries (control group). PD images were interpreted with an angiography-like criteria. RESULTS: In the control group both techniques allowed correct visualization of 16 out of the 18 normal arteries (93% specificity). Only in five hypertensive patients RA stenosis was correctly identified with conventional technique (56% sensitivity and 86% negative predictive value); PD was successful in all hypertensive patients (100% sensitivity and negative predictive value), since the operators could obtain in each case of RA stenosis a sharp color signal of the whole vessel with a clear "minus" at the point of narrowing of the lumen. All results were statistically significant (p < 0.01). CONCLUSIONS: This study demonstrates that PD is superior to conventional imaging, in terms of sensitivity and specificity, for the diagnosis of RA stenosis, because it allows a clear visualization of the whole stenotic vascular lumen. Especially if it is used in concert with the other sonographic techniques, PD can enable a more accurate imaging of renovascular disease with results that seem comparable to selective angiography

    The contrast-enhanced Doppler ultrasound with perfluorocarbon exposed sonicated albumin does not improve the diagnosis of renal artery stenosis compared with angiography

    Get PDF
    There are no studies investigating the effect of the contrast infusion on the sensitivity and specificity of the main Doppler criteria of renal artery stenosis (RAS). Our aim was to evaluate the accuracy of these Doppler criteria prior to and following the intravenous administration of perfluorocarbon exposed sonicated albumin (PESDA) in patients suspected of having RAS. Thirty consecutive hypertensive patients (13 males, mean age of 57 ± 10 years) suspected of having RAS by clinical clues, were submitted to ultrasonography (US) of renal arteries before and after enhancement using continuous infusion of PESDA. All patients underwent angiography, and haemodynamically significant RAS was considered when ≄50%. At angiography, it was detected RAS ≄50% in 18 patients, 5 with bilateral stenosis. After contrast, the examination time was slightly reduced by approximately 20%. In non-enhanced US the sensitivity was better when based on resistance index (82.9%) while the specificity was better when based on renal aortic ratio (89.2%). The predictive positive value was stable for all indexes (74.0%–88.0%) while negative predictive value was low (44%–51%). The specificity and positive predictive value based on renal aortic ratio increased after PESDA injection respectively, from 89 to 97.3% and from 88 to 95%. In hypertensives suspected to have RAS the sensitivity and specificity of Duplex US is dependent of the criterion evaluated. Enhancement with continuous infusion of PESDA improves only the specificity based on renal aortic ratio but do not modify the sensitivity of any index
    • 

    corecore