12 research outputs found

    Robotic right ventricle is a biohybrid platform that simulates right ventricular function in (patho)physiological conditions and intervention

    Get PDF
    The increasing recognition of the right ventricle (RV) necessitates the development of RV-focused interventions, devices and testbeds. In this study, we developed a soft robotic model of the right heart that accurately mimics RV biomechanics and hemodynamics, including free wall, septal and valve motion. This model uses a biohybrid approach, combining a chemically treated endocardial scaffold with a soft robotic synthetic myocardium. When connected to a circulatory flow loop, the robotic right ventricle (RRV) replicates real-time hemodynamic changes in healthy and pathological conditions, including volume overload, RV systolic failure and pressure overload. The RRV also mimics clinical markers of RV dysfunction and is validated using an in vivo porcine model. Additionally, the RRV recreates chordae tension, simulating papillary muscle motion, and shows the potential for tricuspid valve repair and replacement in vitro. This work aims to provide a platform for developing tools for research and treatment for RV pathophysiology.</p

    Importance of Preserved Tricuspid Valve Function for Effective Soft Robotic Augmentation of the Right Ventricle in Cases of Elevated Pulmonary Artery Pressure

    Get PDF
    Purpose: In clinical practice, many patients with right heart failure (RHF) have elevated pulmonary artery pressures and increased afterload on the right ventricle (RV). In this study, we evaluated the feasibility of RV augmentation using a soft robotic right ventricular assist device (SRVAD), in cases of increased RV afterload. Methods: In nine Yorkshire swine of 65-80 kg, a pulmonary artery band was placed to cause RHF and maintained in place to simulate an ongoing elevated afterload on the RV. The SRVAD was actuated in synchrony with the ventricle to augment native RV output for up to one hour. Hemodynamic parameters during SRVAD actuation were compared to baseline and RHF levels. Results: Median RV cardiac index (CI) was 1.43 (IQR, 1.37-1.80) L/min/m(2) and 1.26 (IQR 1.05-1.57) L/min/m(2) at first and second baseline. Upon PA banding RV CI fell to a median of 0.79 (IQR 0.63-1.04) L/min/m(2). Device actuation improved RV CI to a median of 0.87 (IQR 0.78-1.01), 0.85 (IQR 0.64-1.59) and 1.11 (IQR 0.67-1.48) L/min/m(2) at 5 min (p = 0.114), 30 min (p = 0.013) and 60 (p = 0.033) minutes respectively. Statistical GEE analysis showed that lower grade of tricuspid regurgitation at time of RHF (p = 0.046), a lower diastolic pressure at RHF (p = 0.019) and lower mean arterial pressure at RHF (p = 0.024) were significantly associated with higher SRVAD effectiveness. Conclusions: Short-term augmentation of RV function using SRVAD is feasible even in cases of elevated RV afterload. Moderate or severe tricuspid regurgitation were associated with reduced device effectiveness

    Concomitant tuberculosis and hydatid cyst in a solitary pulmonary nodule of left lower lobe

    No full text
    We report a case of a 25-year-old woman who presented with recurrent attacks of haemoptysis over a 12 month period. Physical examination was normal. Chest x ray and computed tomography scan showed a 2.6×1.9 cm pulmonary nodule. Full blood count and biochemical profile were normal. Fibreoptic bronchoscopy was normal and bronchial aspirate was negative for Ziehl-Neelsen staining and malignant cells. The nodule was removed surgically because it was feared that it could be malignant. Histology showed concomitant hydatid disease and tuberculosis. This is a rare occurrence with only one similar case reported in the literature

    Soft robotics-enabled large animal model of HFpEF hemodynamics for device testing

    No full text
    Heart failure with preserved ejection fraction (HFpEF) is a major challenge in cardiovascular medicine, accounting for approximately 50% of all cases of heart failure. Due to the lack of effective therapies for this condition, the mortality associated with HFpEF remains higher than that of most cancers. Despite the ongoing efforts, no medical device has yet received FDA approval. This is largely due to the lack of an in vivo model of the HFpEF hemodynamics, resulting in the inability to evaluate device effectiveness in vivo prior to clinical trials. Here, we describe the development of a highly tunable porcine model of HFpEF hemodynamics using implantable soft robotic sleeves, where controlled actuation of a left ventricular and an aortic sleeve can recapitulate changes in ventricular compliance and afterload associated with a broad spectrum of HFpEF hemodynamic phenotypes. We demonstrate the feasibility of the proposed model in preclinical testing by evaluating the hemodynamic response of the model post-implantation of an interatrial shunt device, which was found to be consistent with findings from in silico studies and clinical trials. This work addresses several of the limitations associated with previous models of HFpEF, such as their limited hemodynamic fidelity, elevated costs, lengthy development time, and low throughput. By showcasing exceptional versatility and tunability, the proposed platform has the potential to revolutionize the current approach for HFpEF device development and selection, with the goal of improving the quality of life for the 32 million people affected by HFpEF worldwide.</p

    An implantable soft robotic ventilator augments inspiration in a pig model of respiratory insufficiency

    No full text
    Severe diaphragm dysfunction can lead to respiratory failure and to the need for permanent mechanical ventilation. Yet permanent tethering to a mechanical ventilator through the mouth or via tracheostomy can hinder a patient’s speech, swallowing ability and mobility. Here we show, in a porcine model of varied respiratory insufficiency, that a contractile soft robotic actuator implanted above the diaphragm augments its motion during inspiration. Synchronized actuation of the diaphragm-assist implant with the native respiratory effort increased tidal volumes and maintained ventilation flow rates within the normal range. Robotic implants that intervene at the diaphragm rather than at the upper airway and that augment physiological metrics of ventilation may restore respiratory performance without sacrificing quality of life

    Modulating cardiac hemodynamics using tunable soft robotic sleeves in a porcine model of HFpEF physiology for device testing applications

    No full text
    Heart failure with preserved ejection fraction (HFpEF) is a major challenge in cardiovascular medicine, accounting for ≈50% of all cases of heart failure. Despite the ongoing efforts, no medical device has yet received FDA approval. This is largely due to the lack of an in vivo model of the HFpEF hemodynamics, resulting in the inability to evaluate device effectiveness in vivo prior to clinical trials. Here, the development of a highly tunable porcine model of HFpEF hemodynamics is described using implantable soft robotic sleeves, where controlled actuation of a left ventricular and an aortic sleeve can recapitulate changes in ventricular compliance and afterload associated with a broad spectrum of HFpEF hemodynamic phenotypes. The feasibility of the proposed model in preclinical testing is demonstrated by evaluating the hemodynamic response of the model post-implantation of an interatrial shunt device, which is found to be consistent with findings from in silico studies and clinical trials. This work overcomes limitations of prior HFpEF models, such as low hemodynamic accuracy, high costs, and long development phases. The versatile and adjustable platform introduced can transform HFpEF device development, aiming to enhance the lives of the 32 million people affected globally.</p

    A Large Animal Model for Acute Kidney Injury by Temporary Bilateral Renal Artery Occlusion

    No full text
    Acute kidney injury (AKI) is associated with higher risk for morbidity and mortality post-operatively. Ischemia-reperfusion injury (IRI) is the most common cause of AKI. To mimic this clinical scenario, this study presents a highly reproducible large animal model of renal IRI in swine using temporary percutaneous bilateral balloon-catheter occlusion of the renal arteries. The renal arteries are occluded for 60 min by introducing the balloon-catheters through the femoral and carotid artery and advancing them into the proximal portion of the arteries. Iodinated contrast is injected in the aorta to assess any opacification of the kidney vessels and confirm the success of the artery occlusion. This is furtherly confirmed by the flattening of the pulse waveform at the tip of the balloon catheters. The balloons are deflated and removed after 60 min of bilateral renal artery occlusion, and the animals are allowed to recover for 24 h. At the end of the study, plasma creatinine and blood urea nitrogen significantly increase, while eGFR and urine output significantly decrease. The need for iodinated contrast is minimal and does not affect renal function. Bilateral renal artery occlusion better mimics the clinical scenario of perioperative renal hypoperfusion, and the percutaneous approach minimizes the impact of the inflammatory response and the risk of infection seen with an open approach, such as a laparotomy. The ability to create and reproduce this clinically relevant swine model eases the clinical translation to humans

    Robotic right ventricle is a biohybrid platform that simulates right ventricular function in (patho)physiological conditions and intervention

    No full text
    The increasing recognition of the right ventricle (RV) necessitates the development of RV-focused interventions, devices and testbeds. In this study, we developed a soft robotic model of the right heart that accurately mimics RV biomechanics and hemodynamics, including free wall, septal and valve motion. This model uses a biohybrid approach, combining a chemically treated endocardial scaffold with a soft robotic synthetic myocardium. When connected to a circulatory flow loop, the robotic right ventricle (RRV) replicates real-time hemodynamic changes in healthy and pathological conditions, including volume overload, RV systolic failure and pressure overload. The RRV also mimics clinical markers of RV dysfunction and is validated using an in vivo porcine model. Additionally, the RRV recreates chordae tension, simulating papillary muscle motion, and shows the potential for tricuspid valve repair and replacement in vitro. This work aims to provide a platform for developing tools for research and treatment for RV pathophysiology.</p

    Mitochondrial transplantation for myocardial protection in ex-situ‒perfused hearts donated after circulatory death

    No full text
    BACKGROUND: Donation after circulatory death (DCD) offers an additional source of cardiac allog-rafts, potentially allowing expansion of the donor pool, but is limited owing to the effects of ischemia. In this study, we investigated the efficacy of mitochondrial transplantation to enhance myocardial function of DCD hearts.METHODS: Circulatory death was induced in Yorkshire pigs (40-50 kg, n = 29) by a cessation of mechanical ventilation. After 20 minutes of warm ischemia, cardioplegia was administered. The hearts were then reperfused on an ex-situ blood perfusion system. After 15 minutes of reperfusion, hearts received either vehicle alone (vehicle [VEH], 10 ml; n = 8) or vehicle containing autologous mitochondria (vehicle with mitochondria as a single injection [MT], 5 x 10(9) in 10 ml, n = 8). Another group of hearts (serial injection of mitochondria [MTS]; n = 6) received a second injection of mitochondria (5 x 10(9) in 10 ml) after 2 hours of ex-situ heart perfusion and reperfused for an additional 2 hours. A Sham group (sham hearts; n = 6) did not undergo any warm ischemia.RESULTS: At the end of 4 hours of reperfusion, MT and MTS groups showed a significantly increased left ventricle/ventricular peak developed pressure (p = 0.002), maximal left ventricle/ventricular pressure rise (p < 0.001), fractional shortening (p < 0.001), and myocardial oxygen consumption (p = 0.004) compared with VEH. Infarct size was significantly decreased in MT and MTS groups compared with VEH (p < 0.001). No differences were found in arterial lactate levels among or within groups throughout reperfusion.CONCLUSIONS: Mitochondrial transplantation significantly preserves myocardial function and oxygen consumption in DCD hearts, thus providing a possible option for expanding the heart donor pool. (C) 2020 International Society for Heart and Lung Transplantation. All rights reserved

    A Novel Biological Strategy for Myocardial Protection by Intracoronary Delivery of Mitochondria: Safety and Efficacy

    No full text
    Mitochondrial dysfunction is the determinant insult of ischemia-reperfusion injury. Autologous mitochondrial transplantation involves supplying one's healthy mitochondria to the ischemic region harboring damaged mitochondria. The authors used in vivo swine to show that mitochondrial transplantation in the heart by intracoronary delivery is safe, with specific distribution to the heart, and results in significant increase in coronary blood flow, which requires intact mitochondrial viability, adenosine triphosphate production, and, in part, the activation of vascular Km channels. Intracoronary mitochondrial delivery after temporary regional ischemia significantly improved myocardial function, perfusion, and infarct size. The authors concluded that intracoronary delivery of mitochondria is safe and efficacious therapy for myocardial ischemia-reperfusion injury. (C) 2019 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation
    corecore