10 research outputs found

    Bias voltage Control of Avalanche Photo-Diode Using a Window Comparator

    Full text link
    This work aims at controlling the bias voltage of APDs, used for single photon detection, with a micro-controller through pulse height comparison.Comment: 2011 IEEE Summer Topicals Conference proceedin

    Realizing a Robust, Reconfigurable Active Quenching Design for Multiple Types of Single-Photon Avalanche Detectors

    Full text link
    Most active quench circuits used for single-photon avalanche photodetectors (APDs) are designed either with discrete components which lack the flexibility of dynamically changing the control parameters, or with custom ASICs which require a long development time and high cost. As an alternative, we present a reconfigurable and robust hybrid design implemented using a System-on-Chip (SoC), which integrates both an FPGA and a microcontroller. We take advantage of the FPGA's speed and reconfiguration capabilities to vary the quench and reset parameters dynamically over a large range, thus allowing our system to operate a variety of APDs without changing the design. The microcontroller enables the remote adjustment of control parameters and calibration of APDs in the field. The ruggedized design uses components with space heritage, thus making it suitable for space-based applications in the fields of telecommunications and quantum key distribution (QKD). We demonstrate our circuit by operating a commercial APD cooled to -20{\deg}C with a deadtime of 35ns while maintaining the after-pulsing probability at close to 3%. We also showcase its versatility by operating custom-fabricated chip-scale APDs, which paves the way for automated wafer-scale characterization.Comment: 6 pages, 6 figures. arXiv admin note: substantial text overlap with arXiv:2205.0022

    Entanglement demonstration on board a nano-satellite

    Get PDF
    Global quantum networks for secure communication can be realized using large fleets of satellites distributing entangled photon pairs between ground-based nodes. Because the cost of a satellite depends on its size, the smallest satellites will be most cost-effective. This Letter describes a miniaturized, polarization entangled, photon-pair source operating on board a nano-satellite. The source violates Bell’s inequality with a Clauser–Horne–Shimony–Holt parameter of 2.60±0.06. This source can be combined with optical link technologies to enable future quantum communication nano-satellite missions

    SpooQy-1: The First Nano-Satellite to Demonstrate Quantum Entanglement in Space

    Get PDF
    SpooQy-1 is a 3-unit nanosatellite that was launched into a Low Earth Orbit from the International Space Station on the 17th of June 2019. The spacecraft hosts a scientific payload capable of producing entangled photon-pairs and measuring their polarization in orthogonal bases to perform a Bell test. Since launch, SpooQy-1 has routinely demonstrated the generation and detection of polarization entangled photon-pairs in Space, something that has previously only been demonstrated by the 630kg Micius mission by the Chinese Academy of Sciences. The measured entanglement correlations can violate Bell\u27s inequality with a CHSH parameter value of 2.60±0.06, over operating temperatures of 16 °C to 21.5 °C. These results demonstrate that quantum entanglement can be generated in space on highly resource-constrained platforms. A follow-on 12U mission, developed in partnership with RAL space,will build on this to demonstrate space-to-ground entanglement distribution, which is required for space-based nodes to support global quantum communication networks

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Nutzenbewertung von Trainingsinterventionen für die Sturzprophylaxe bei älteren Menschen - eine systematische Übersicht auf der Grundlage systematischer Übersichten

    No full text

    Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures

    No full text

    Femoral Neck Shortening After Hip Fracture Fixation Is Associated With Inferior Hip Function : Results From the FAITH Trial

    No full text

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between Mar

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    corecore