85 research outputs found

    In Vivo Ultrasonic Detection of Polyurea Crosslinked Silica Aerogel Implants

    Get PDF
    Background:Polyurea crosslinked silica aerogels are highly porous, lightweight, and mechanically strong materials with great potential for in vivo applications. Recent in vivo and in vitro studies have demonstrated the biocompatibility of this type of aerogel. the highly porous nature of aerogels allows for exceptional thermal, electric, and acoustic insulating capabilities that can be taken advantage of for non-invasive external imaging techniques. Sound-based detection of implants is a low cost, non-invasive, portable, and rapid technique that is routinely used and readily available in major clinics and hospitals.Methodology:In this study the first in vivo ultrasound response of polyurea crosslinked silica aerogel implants was investigated by means of a GE Medical Systems LogiQe diagnostic ultrasound machine with a linear array probe. Aerogel samples were inserted subcutaneously and sub-muscularly in a) fresh animal model and b) cadaveric human model for analysis. For comparison, samples of polydimethylsiloxane (PDMS) were also imaged under similar conditions as the aerogel samples.Conclusion/significance:Polyurea crosslinked silica aerogel (X-Si aerogel) implants were easily identified when inserted in either of the regions in both fresh animal model and cadaveric model. the implant dimensions inferred from the images matched the actual size of the implants and no apparent damage was sustained by the X-Si aerogel implants as a result of the ultrasonic imaging process. the aerogel implants demonstrated hyperechoic behavior and significant posterior shadowing. Results obtained were compared with images acquired from the PDMS implants inserted at the same location

    Noninvasive Detection, Tracking, and Characterization of Aerogel Implants using Diagnostic Ultrasound

    Get PDF
    Medical implants are routinely tracked and monitored using different techniques, such as MRI, X‐ray, and ultrasound. Due to the need for ionizing radiation, the two former methods pose a significant risk to tissue. Ultrasound imaging, however, is non‐invasive and presents no known risk to human tissue. Aerogels are an emerging material with great potential in biomedical implants. While qualitative observation of ultrasound images by experts can already provide a lot of infor-mation about the implants and the surrounding structures, this paper describes the development and study of two simple B‐Mode image analysis techniques based on attenuation measurements and echogenicity comparisons, which can further enhance the study of the biological tissues and implants, especially of different types of biocompatible aerogels

    Histological Evaluation of the Biocompatibility of Polyurea Crosslinked Silica Aerogel Implants in a Rat Model: A Pilot Study

    Get PDF
    Background: Aerogels are a versatile group of nanostructured/nanoporous materials with physical and chemical properties that can be adjusted to suit the application of interest. In terms of biomedical applications, aerogels are particularly suitable for implants such as membranes, tissue growth scaffolds, and nerve regeneration and guidance inserts. The mesoporous nature of aerogels can also be used for diffusion based release of drugs that are loaded during the drying stage of the material. From the variety of aerogels polyurea crosslinked silica aerogels have the most potential for future biomedical applications and are explored here. Methodology: This study assessed the short and long term biocompatibility of polyurea crosslinked silica aerogel implants in a Sprague-Dawley rat model. Implants were inserted at two different locations a) subcutaneously (SC), at the dorsum and b) intramuscularly (IM), between the gluteus maximus and biceps femoris of the left hind extremity. Nearby muscle and other internal organs were evaluated histologically for inflammation, tissue damage, fibrosis and movement (travel) of implant. Conclusion/Significance: In general polyurea crosslinked silica aerogel (PCSA) was well tolerated as a subcutaneous and an intramuscular implant in the Sprague-Dawley rat with a maximum incubation time of twenty months. In some cases a thin fibrous capsule surrounded the aerogel implant and was interpreted as a normal response to foreign material. No noticeable toxicity was found in the tissues surrounding the implants nor in distant organs. Comparison was made with control rats without any implants inserted, and animals with suture material present. No obvious or noticeable changes were sustained by the implants at either location. Careful necropsy and tissue histology showed age-related changes only. An effective sterilization technique for PCSA implants as well as staining and sectioning protocol has been established. These studies further support the notion that silica-based aerogels could be useful as biomaterials. © 2012 Sabri et al

    Investigation of Polyurea-Crosslinked Silica Aerogels as a Neuronal Scaffold: A Pilot Study

    Get PDF
    BACKGROUND: Polymer crosslinked aerogels are an attractive class of materials for future implant applications particularly as a biomaterial for the support of nerve growth. The low density and nano-porous structure of this material combined with large surface area, high mechanical strength, and tunable surface properties, make aerogels materials with a high potential in aiding repair of injuries of the peripheral nervous system. however, the interaction of neurons with aerogels remains to be investigated. METHODOLOGY: In this work the attachment and growth of neurons on clear polyurea crosslinked silica aerogels (PCSA) coated with: poly-L-lysine, basement membrane extract (BME), and laminin1 was investigated by means of optical and scanning electron microscopy. After comparing the attachment and growth capability of neurons on these different coatings, laminin1 and BME were chosen for nerve cell attachment and growth on PCSA surfaces. The behavior of neurons on treated petri dish surfaces was used as the control and behavior of neurons on treated PCSA discs was compared against it. CONCLUSIONS/SIGNIFICANCE: This study demonstrates that: 1) untreated PCSA surfaces do not support attachment and growth of nerve cells, 2) a thin application of laminin1 layer onto the PCSA discs adhered well to the PCSA surface while also supporting growth and differentiation of neurons as evidenced by the number of processes extended and b3-tubulin expression, 3) three dimensional porous structure of PCSA remains intact after fixing protocols necessary for preservation of biological samples and 4) laminin1 coating proved to be the most effective method for attaching neurons to the desired regions on PCSA discs. This work provides the basis for potential use of PCSA as a biomaterial scaffold for neural regeneration

    Polymer-encapsulated phosphor particles for in vivo phosphor luminescence applications

    No full text
    Phosphor thermometry is a highly sensitive, rapid, and portable thermal sensing technique that offers advantages over traditional contact-based thermometry techniques. Phosphor particles would however require an encapsulation medium that is biocompatible and yet optically transparent to permit optical access to the embedded phosphor particles. Here, phosphor-doped silicone implants with varying concentrations were prepared and tested in a rat model. Results indicate that such phosphor-doped polymeric implants are stable, produce a detectable signal, and demonstrate the feasibility of phosphor thermometry as a noninvasive remote thermal sensing technique for in vivo applications. Also, encapsulation in silicone did not lead to significant attenuation of the incoming signal

    Optimal structural and physical properties of aerogels for promoting robust neurite extension in vitro

    No full text
    Cell behaviour is influenced by external factors including the physical properties of the substrate such as its surface topography and stiffness. Recent studies have demonstrated the potential of aerogels as biomaterials and specifically as neural scaffolds. The 3-D structure inherent to aerogels offers an advantage over other biocompatible substrates which lack the dimensionality needed to mimic the in vivo topography of tissues. Here, we used a variety of aerogel types to correlate the extension of neurites by neuronal cells with surface roughness ranging from 0 to 3 ÎŒm and stiffness 10 kPa-4 MPa. This investigation reveals that the optimal surface features for neurite extension are a surface roughness of 0.5 ÎŒm and a Young\u27s modulus between 1 and 3.5 MPa. The significance of these findings to optimize materials for nerve repair is discussed

    Investigation of surface topography and stiffness on adhesion and neurites extension of PC12 cells on crosslinked silica aerogel substrates.

    No full text
    Fundamental understanding and characterization of neural response to substrate topography is essential in the development of next generation biomaterials for nerve repair. Aerogels are a new class of materials with great potential as a biomaterial. In this work, we examine the extension of neurites by PC12 cells plated on matrigel-coated and collagen-coated mesoporous aerogel surfaces. We have successfully established the methodology for adhesion and growth of PC12 cells on polyurea crosslinked silica aerogels. Additionally, we have quantified neurite behaviors and compared their response on aerogel substrates with their behavior on tissue culture (TC) plastic, and polydimethylsiloxane (PDMS). We found that, on average, PC12 cells extend longer neurites on crosslinked silica aerogels than on tissue culture plastic, and, that the average number of neurites per cluster is lower on aerogels than on tissue culture plastic. Aerogels are an attractive candidate for future development of smart neural implants and the work presented here creates a platform for future work with this class of materials as a substrate for bioelectronic interfacing

    Spincoat-fabricated multilayer PDMS-phosphor composites for thermometry

    No full text
    Phosphor thermometry offers unique advantages over traditional forms of temperature sensing. Polymer-encapsulated phosphor powders provide versatility and flexibility not achievable when using the thermographic phosphors in powder form. By encapsulating the powder in a polymeric sleeve custom devices with unique properties can be created. Here, the authors report on the design, synthesis, and characterization of the first multilayer thermographic phosphor structure. A thin layer of neat PDMS, Sylgard 184, was sandwiched between two layers of La2O2S:Eu phosphor-doped PDMS. The thicknesses ranged from 0.15 to 4 mm depending on spin speed. The temperature dependent luminescence of the structure was characterized from -40 °C to 75 °C, in a low humidity environmental chamber. Results show suitability for thermometry in this range. In addition, for design guidance, quantitative values for thermal conductivity and stress/strain characteristics versus phosphor loading percentage and temperature were measured. Thermal conductivities ranged from 0.15 W mK-1 for the Sylgard 184 to a value between 0.3 and 0.4 W mK-1 for pure phosphor powder for temperatures from -55 °C to 195 °C. Tensile properties for a strain of up to 1 revealed differences between the different phosphor loadings and phosphor batches. Young\u27s modulus for the spincoat layered materials was between 1.2 and 1.4 N mm-2 and 0.8 for drop casted samples

    Growing Neural PC-12 Cell on Crosslinked Silica Aerogels Increases Neurite Extension in the Presence of an Electric Field

    No full text
    Externally applied electrical stimulation (ES) has been shown to enhance the nerve regeneration process and to influence the directionality of neurite outgrowth. In addition, the physical and chemical properties of the substrate used for nerve-cell regeneration is critical in fostering regeneration. Previously, we have shown that polyurea-crosslinked silica aerogels (PCSA) exert a positive influence on the extension of neurites by PC-12 cells, a cell-line model widely used to study neurite extension and electrical excitability. In this work, we have examined how an externally applied electric field (EF) influences the extension of neurites in PC-12 cells grown on two substrates: collagen-coated dishes versus collagen-coated crosslinked silica aerogels. The externally applied direct current (DC) bias was applied in vitro using a custom-designed chamber containing polydimethysiloxane (PDMS) embedded copper electrodes to create an electric field across the substrate for the cultured PC-12 cells. Results suggest orientation preference towards the anode, and, on average, longer neurites in the presence of the applied DC bias than with 0 V DC bias. In addition, neurite length was increased in cells grown on silica-crosslinked aerogel when compared to cells grown on regular petri-dishes. These results further support the notion that PCSA is a promising material for nerve regeneration
    • 

    corecore