142 research outputs found

    Neck fracture of a cementless forged titanium alloy femoral stem following total hip arthroplasty: a case report and review of the literature

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Fractures of the neck of the femoral component have been reported in uncemented total hip replacements, however, to our knowledge, no fractures of the neck of a cementless forged titanium alloy femoral stem coated in the proximal third with hydroxy-apatite have been reported in the medical literature.</p> <p>Case presentation</p> <p>This case report describes a fracture of the neck of a cementless forged titanium alloy stem coated in the proximal third with hydroxy-apatite.</p> <p>Conclusion</p> <p>The neck of the femoral stem failed from fatigue probably because of a combination of factors described analytically below.</p

    The relationship of the factor V Leiden mutation or the deletion-deletion polymorphism of the angiotensin converting enzyme to postoperative thromboembolic events following total joint arthroplasty

    Get PDF
    BACKGROUND: Although all patients undergoing total joint arthroplasty are subjected to similar risk factors that predispose to thromboembolism, only a subset of patients develop this complication. The objective of this study was to determine whether a specific genetic profile is associated with a higher risk of developing a postoperative thromboembolic complication. Specifically, we examined if the Factor V Leiden (FVL) mutation or the deletion polymorphism of the angiotensin-converting enzyme (ACE) gene increased a patient's risk for postoperative thromboembolic events. The FVL mutation has been associated with an increased risk of idiopathic thromboembolism and the deletion polymorphism of the ACE gene has been associated with increased vascular tone, attenuated fibrinolysis and increased platelet aggregation. METHODS: The presence of these genetic profiles was determined for 38 patients who had a postoperative symptomatic pulmonary embolus or proximal deep venous thrombosis and 241 control patients without thrombosis using molecular biological techniques. RESULTS: The Factor V Leiden mutation was present in none of the 38 experimental patients and in 3% or 8 of the 241 controls (p = 0.26). Similarly there was no difference detected in the distribution of polymorphisms for the ACE gene with the deletion-deletion genotype present in 36% or 13 of the 38 experimental patients and in 31% or 74 of the 241 controls (p = 0.32). CONCLUSIONS: Our results suggest that neither of these potentially hypercoaguable states are associated with an increased risk of symptomatic thromboembolic events following total hip or knee arthroplasty in patients receiving pharmacological thromboprophylaxis

    A New Digital Preoperative Planning Method for Total Hip Arthroplasties

    Get PDF
    Preoperative templating is an important part of a THA. The ability to accurately determine magnification of the hip on the radiograph and apply identical magnification to the radiograph and template will improve accuracy of preoperative templating of THA. We designed a templating method using a new way of determining the hip magnification with a linear relationship between magnification of the hip and the reference object on top of the pubis symphysis; the relationship was determined on 50 radiographs. We then compared our method with two other templating methods: an analog method assuming an average hip magnification of 15% and a digital method determining the hip magnification with a one-to-one relationship between the reference object and the hip. All methods were reproducible. Uniform undersizing occurred when templating with the digital method based on the one-to-one relationship; the analog method best predicted the implanted prosthesis size, closely followed by our new digital templating method; the new method will be particularly applicable for preoperative THA when analog methods are replaced by digital methods

    Less Anterior Knee Pain with a Mobile-bearing Prosthesis Compared with a Fixed-bearing Prosthesis

    Get PDF
    Anterior knee pain is one of the major short-term complaints after TKA. Since the introduction of the mobile-bearing TKA, numerous studies have attempted to confirm the theoretical advantages of a mobile-bearing TKA over a fixed-bearing TKA but most show little or no actual benefits. The concept of self-alignment for the mobile bearing suggests the posterior-stabilized mobile-bearing TKA would provide a lower incidence of anterior knee pain compared with a fixed-bearing TKA. We therefore asked whether the posterior-stabilized mobile-bearing knee would in fact reduce anterior knee pain. We randomized 103 patients scheduled for cemented three-component TKA for osteoarthrosis in a prospective, double-blind clinical trial. With a 1-year followup, more patients experienced persistent anterior knee pain in the posterior-stabilized fixed-bearing group (10 of 53, 18.9%) than in the posterior-stabilized mobile-bearing group (two of 47, 4.3%). No differences were observed for range of motion, visual analog scale for pain, Oxford 12-item questionnaire, SF-36, or the American Knee Society score. The posterior-stabilized mobile-bearing knee therefore seems to provide a short-term advantage compared with the posterior-stabilized fixed-bearing knee

    A comparison of missing data methods for hypothesis tests of the treatment effect in substance abuse clinical trials: a Monte-Carlo simulation study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Missing data due to attrition are rampant in substance abuse clinical trials. However, missing data are often ignored in the presentation of substance abuse clinical trials. This paper demonstrates missing data methods which may be used for hypothesis testing.</p> <p>Methods</p> <p>Methods involving stratifying and weighting individuals based on missing data pattern are shown to produce tests that are robust to missing data mechanisms in terms of Type I error and power. In this article, we describe several methods of combining data that may be used for testing hypotheses of the treatment effect. Furthermore, illustrations of each test's Type I error and power under different missing data percentages and mechanisms are quantified using a Monte-Carlo simulation study.</p> <p>Results</p> <p>Type I error rates were similar for each method, while powers depended on missing data assumptions. Specifically, power was greatest for the weighted, compared to un-weighted methods, especially for greater missing data percentages.</p> <p>Conclusion</p> <p>Results of this study as well as extant literature demonstrate the need for standards of design and analysis specific to substance abuse clinical trials. Given the known substantial attrition rates and concern for the missing data mechanism in substance abuse clinical trials, investigators need to incorporate missing data methods a priori. That is, missing data methods should be specified at the outset of the study and not after the data have been collected.</p

    Effectiveness of computer-navigated minimally invasive total hip surgery compared to conventional total hip arthroplasty: design of a randomized controlled trial

    Get PDF
    BACKGROUND: Moderate to severe osteoarthrosis is the most common indication for Total Hip Arthroplasty (THA). Minimally Invasive Total Hip Surgery (MIS) and computer-navigated surgery were introduced several years ago. However, the literature lacks well-designed studies that provide evidence of superiority of computer-navigated MIS over a conventional THA technique. Hence, the purpose of this study is to compare (cost)effectiveness of computer-navigated MIS with a conventional technique for THA. It is our hypothesis that computer-navigated MIS will lead to a quicker recovery during the early postoperative period (3 months), and to an outcome at least as good 6 months postoperatively. We also hypothesize that computer-navigated MIS leads to fewer perioperative complications and better prosthesis positioning. Furthermore, cost advantages of computer-navigated MIS over conventional THA technique are expected. METHODS/DESIGN: A cluster randomized controlled trial will be executed. Patients between the ages of 18 and 75 admitted for primary cementless unilateral THA will be included. Patients will be stratified using the Charnley classification. They will be randomly allocated to have computer-navigated MIS or conventional THA technique. Measurements take place preoperatively, perioperatively, and 6 weeks and 3 and 6 months postoperatively. Degree of limping (gait analysis), self-reported functional status and health-related quality of life (questionnaires) will be assessed preoperatively as well as postoperatively. Perioperative complications will be registered. Radiographic evaluation of prosthesis positioning will take place 6 weeks postoperatively. An evaluation of costs within and outside the healthcare sector will focus on differences in costs between computer-navigated MIS and conventional THA technique. DISCUSSION: Based on studies performed so far, few objective data quantifying the risks and benefits of computer-navigated MIS are available. Therefore, this study has been designed to compare (cost) effectiveness of computer-navigated MIS with a conventional technique for THA. The results of this trial will be presented as soon as they become available

    A new short uncemented, proximally fixed anatomic femoral implant with a prominent lateral flare: design rationals and study design of an international clinical trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Anatomic short femoral prostheses with a prominent lateral flare have the potential to reduce stress-shielding in the femur through a more physiological stress distribution to the proximal femur. We present the design rationale of a new short uncemented, proximally fixed anatomic femoral implant and the study design of a prospective multi-centre trial to collect long-term patient outcome and radiographic follow up data.</p> <p>Methods</p> <p>A prospective surveillance study (trial registry NCT00208555) in four European centres (UK, Italy, Spain and Germany) with a follow up period of 15 years will be executed. The recruitment target is 200 subjects, patients between the ages of 18 and 70 admitted for primary cementless unilateral THA will be included. The primary objective is to evaluate the five-year survivorship of the new cementless short stem. The secondary objectives of this investigation are to evaluate the long term survivorship and the clinical performance of the implant, the impact on the subjects health related Quality of Life and the affect of the prosthesis on bone mineral density. Peri- and postoperative complications will be registered. Clinical and radiographic evaluation of prosthesis positioning will be done post-operatively and at 3, 6, 12, 24, 60, 120 and 180 months follow up.</p> <p>Discussion</p> <p>Shortening of the distal stem can maximise bone and soft tissue conservation. New stem types have been designed to improve the limitations of traditional implants in primary THA. A new, uncemented femoral short stem is introduced in this paper. A long-term follow up study has been designed to verify stable fixation and to research into the clinical outcome. The results of this trial will be presented as soon as they become available.</p

    Minimally Invasive Surgical Approaches and Traditional Total Hip Arthroplasty: A Meta-Analysis of Radiological and Complications Outcomes

    Get PDF
    BACKGROUND: Minimally invasive total hip arthroplasty (MITHA) remains considerably controversial. Limited visibility and prosthesis malposition increase the risk of post-surgical complications compared to those of the traditional method. METHODS: A meta-analysis was undertaken of all published databases up to May 2011. The studies were divided into four subgroups according to the surgical approach taken. The radiological outcomes and complications of minimally invasive surgery were compared to traditional total hip arthroplasty (TTHA) using risk ratio, mean difference, and standardized mean difference statistics. RESULTS: In five studies involving the posterolateral approach, no significant differences were found between the MITHA groups and the TTHA groups in the acetabular cup abduction angle (p = 0.41), acetabular anteversion (p = 0.96), and femoral prosthesis position (p = 0.83). However, the femoral offset was significantly increased (WMD = 3.00; 95% CI, 0.40-5.60; p = 0.02). Additionally, there were no significant differences among the complications in both the groups (dislocations, nerve injury, infection, deep vein thrombosis, proximal femoral fracture) and revision rate (p>0.05). In three studies involving the posterior approach, there were no significant differences in radiological outcomes or all other complications between MITHA or TTHA groups (p>0.05). Three studies involved anterolateral approach, while 2 studies used the lateral approach. However, the information from imaging and complications was not adequate for statistical analysis. CONCLUSIONS: Posterior MITHA seems to be a safe surgical procedure, without the increased risk of post-operative complication rates and component malposition rates. The posterolateral approach THA may lead to increased femoral offset. The current data are not enough to reach a positive conclusion that lateral and anterolateral approaches will result in increased risks of adverse effects and complications at the prosthesis site

    Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature

    Get PDF
    ABSTRACT: BACKGROUND: Both minimally invasive surgery (MIS) and computer-assisted surgery (CAS) for total hip arthroplasty (THA) have gained popularity in recent years. We conducted a qualitative and systematic review to assess the effectiveness of MIS, CAS and computer-assisted MIS for THA. METHODS: An extensive computerised literature search of PubMed, Medline, Embase and OVIDSP was conducted. Both randomised clinical trials and controlled clinical trials on the effectiveness of MIS, CAS and computer-assisted MIS for THA were included. Methodological quality was independently assessed by two reviewers. Effect estimates were calculated and a best-evidence synthesis was performed. RESULTS: Four high-quality and 14 medium-quality studies with MIS THA as study contrast, and three high-quality and four medium-quality studies with CAS THA as study contrast were included. No studies with computer-assisted MIS for THA as study contrast were identified. Strong evidence was found for a decrease in operative time and intraoperative blood loss for MIS THA, with no difference in complication rates and risk for acetabular outliers. Strong evidence exists that there is no difference in physical functioning, measured either by questionnaires or by gait analysis. Moderate evidence was found for a shorter length of hospital stay after MIS THA. Conflicting evidence was found for a positive effect of MIS THA on pain in the early postoperative period, but that effect diminished after three months postoperatively. Strong evidence was found for an increase in operative time for CAS THA, and limited evidence was found for a decrease in intraoperative blood loss. Furthermore, strong evidence was found for no difference in complication rates, as well as for a significantly lower risk for acetabular outliers. CONCLUSIONS: The results indicate that MIS THA is a safe surgical procedure, without increases in operative time, blood loss, operative complication rates and component malposition rates. However, the beneficial effect of MIS THA on functional recovery has to be proven. The results also indicate that CAS THA, though resulting in an increase in operative time, may have a positive effect on operative blood loss and operative complication rates. More importantly, the use of CAS results in better positioning of acetabular component of the prosthesis
    corecore