44 research outputs found

    Coverage of Axillary Lymph Nodes with Tangential Breast Irradiation in Korea: A Multi-Institutional Comparison Study

    No full text
    Introduction. To evaluate the dose distribution and coverage of axilla using only tangential field for whole breast radiotherapy (RT) at three institutions in Korea. Methods. We used computed tomography (CT) images of nine consecutive 1-2 sentinel lymph node-positive patients who underwent breast conserving surgery and whole breast RT without axillary lymph node (ALN) dissection for clinical T1-2N0 breast cancer. The CT data were transferred to three radiation oncologists in 3 institutions and each radiation oncologist created treatment plans for all nine patients; a total of 27 treatment plans were analyzed. Results. The mean doses delivered to levels I and II were 31.9 Gy (9.9–47.9 Gy) and 22.3 Gy (3.4–47.7 Gy). Ninety-five percent of levels I and II received a mean dose of 11.8 Gy (0.4–43.0 Gy) and 3.0 Gy (0.3–40.0 Gy). The percent volumes of levels I and II covered by 95% of the prescribed dose were only 29.0% (0.2–74.1%) and 11.5% (0.0–70.1%). The dose distribution and coverage of axilla were significantly different between three institutions (p=0.001). Conclusion. There were discrepancies in ALN coverage between three institutions. A standardization of whole breast RT technique through further research with a nationwide scale is needed

    2. Ein Mariageheimnis? – Maria in der markinischen Passion

    No full text

    Feasibility of stereotactic radiotherapy for lung lesions and conventional radiotherapy for nodal areas in primary lung malignancies

    No full text
    Abstract Background Combined stereotactic body radiotherapy (SBRT) for lung lesions and conventional radiotherapy (CRT) for nodal areas may be more effective than CRT alone in patients with locally advanced lung cancer. Methods This study included 21 patients with small primary lung tumors distant from the regional nodal areas. The SBRT dose was 40–60 Gy in 4 fractions. CRT doses were 66 Gy in 30 fractions for non-small cell lung cancer and 52.5 Gy in 25 fractions for small cell lung cancer. Results The median follow-up duration was 12 months, and the median survival was 13 months. The 1 year overall survival, local recurrence-free survival, and distant metastasis-free survival rates were 60.5, 84.8, and 62.1%, respectively. Two patients experienced in-field local recurrence combined with out-field regional recurrence and/or distant failure. The major recurrence pattern was distant failure (crude incidence, 43%). Three patients aged ≥79 years experienced grade ≥ 3 acute radiation pneumonitis, and one also had idiopathic interstitial pneumonia. Conclusion The combination of SBRT for the lung lesion and CRT for the nodal region seems to be effective and safe for lung malignancies. However, patients older in age and/or with underlying pulmonary disease require stricter lung dose constraints

    Improving Delivery Accuracy of Stereotactic Body Radiotherapy to a Moving Tumor Using Simplified Volumetric Modulated Arc Therapy.

    No full text
    PURPOSE:To develop a simplified volumetric modulated arc therapy (VMAT) technique for more accurate dose delivery in thoracic stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS:For each of the 22 lung SBRT cases treated with respiratory-gated VMAT, a dose rate modulated arc therapy (DrMAT) plan was retrospectively generated. A dynamic conformal arc therapy plan with 33 adjoining coplanar arcs was designed and their beam weights were optimized by an inverse planning process. All sub-arc beams were converted into a series of control points with varying MLC segment and dose rates and merged into an arc beam for a DrMAT plan. The plan quality of original VMAT and DrMAT was compared in terms of target coverage, compactness of dose distribution, and dose sparing of organs at risk. To assess the delivery accuracy, the VMAT and DrMAT plans were delivered to a motion phantom programmed with the corresponding patients' respiratory signal; results were compared using film dosimetry with gamma analysis. RESULTS:The plan quality of DrMAT was equivalent to that of VMAT in terms of target coverage, dose compactness, and dose sparing for the normal lung. In dose sparing for other critical organs, DrMAT was less effective than VMAT for the spinal cord, heart, and esophagus while being well within the limits specified by the Radiation Therapy Oncology Group. Delivery accuracy of DrMAT to a moving target was similar to that of VMAT using a gamma criterion of 2%/2mm but was significantly better using a 2%/1mm criterion, implying the superiority of DrMAT over VMAT in SBRT for thoracic/abdominal tumors with respiratory movement. CONCLUSION:We developed a DrMAT technique for SBRT that produces plans of a quality similar to that achieved with VMAT but with better delivery accuracy. This technique is well-suited for small tumors with motion uncertainty

    Dosimetric evaluation of respiratory gated volumetric modulated arc therapy for lung stereotactic body radiation therapy using 3D printing technology.

    No full text
    PurposeThis study aimed to evaluate the dosimetric accuracy of respiratory gated volumetric modulated arc therapy (VMAT) for lung stereotactic body radiation therapy (SBRT) under simulation conditions similar to the actual clinical situation using patient-specific lung phantoms and realistic target movements.MethodsSix heterogeneous lung phantoms were fabricated using a 3D-printer (3DISON, ROKIT, Seoul, Korea) to be dosimetrically equivalent to actual target regions of lung SBRT cases treated via gated VMAT. They were designed to move realistically via a motion device (QUASAR, Modus Medical Devices, Canada). Using the lung phantoms and a homogeneous phantom (model 500-3315, Modus Medical Devices), film dosimetry was performed with and without respiratory gating for VMAT delivery (TrueBeam STx; Varian Medical Systems, Palo Alto, CA, USA). The measured results were analyzed with the gamma passing rates (GPRs) of 2%/1 mm criteria, by comparing with the calculated dose via the AXB and AAA algorithms of the Eclipse Treatment Planning System (version 10.0.28; Varian Medical Systems).ResultsGPRs were greater than the acceptance criteria 80% for all film measurements with the stationary and homogeneous phantoms in conventional QAs. Regardless of the heterogeneity of phantoms, there were no significant differences (p > 0.05) in GPRs obtained with and without target motions; the statistical significance (p = 0.031) was presented between both algorithms under the utilization of heterogeneous phantoms.ConclusionsDosimetric verification with heterogeneous patient-specific lung phantoms could be successfully implemented as the evaluation method for gated VMAT delivery. In addition, it could be dosimetrically confirmed that the AXB algorithm improved the dose calculation accuracy under patient-specific simulations using 3D printed lung phantoms
    corecore