Study of early warning for desaturation provided by Oxygen Reserve Index in obese patients.
Acute hemoglobin desaturation can reflect rapidly decreasing PaO2. Pulse oximetry saturation (SpO2) facilitates hypoxia detection but may not significantly decrease until PaO2 < 80 mmHg. The Oxygen Reserve Index (ORI) is a unitless index that correlates with moderately hyperoxic PaO2. This study evaluated whether ORI provides added arterial desaturation warning in obese patients. This IRB approved, prospective, observational study obtained written informed consent from Obese (body mass index (BMI) kg m-2; 30 < BMI < 40) and Normal BMI (19 < BMI < 25) adult patients scheduled for elective surgery requiring general endotracheal anesthesia. Standard monitors and an ORI sensor were placed. Patient's lungs were pre-oxygenated with 100% FiO2. After ORI plateaued, general anesthesia was induced, and endotracheal intubation accomplished using a videolaryngoscope. Patients remained apneic until SpO2reached 94%. ORI and SpO2 were recorded continuously. Added warning time was defined as the difference between the time to SpO2 94% from ORI alarm start or from SpO2 97%. Data are reported as median; 95% confidence interval. Complete data were collected in 36 Obese and 36 Normal BMI patients. ORI warning time was always longer than SpO2 warning time. Added warning time provided by ORI was 46.5 (36.0-59.0) seconds in Obese and 87.0 (77.0-109.0) seconds in Normal BMI patients, and was shorter in Obese than Normal BMI patients difference 54.0 (38.0-74.0) seconds (p < 0.0001). ORI provided what was felt to be clinically significant added warning time of arterial desaturation compared to SpO2. This added time might allow earlier calls for help, assistance from other providers, or modifications of airway management.Trial registration ClinicalTrials.gov NCT03021551
The case for a 3rd generation supraglottic airway device facilitating direct vision placement
Although 1st and 2nd generation supraglottic airway devices (SADs) have many desirable features, they are nevertheless inserted in a similar ‘blind’ way as their 1st generation predecessors. Clinicians mostly still rely entirely on subjective indirect assessments to estimate correct placement which supposedly ensures a tight seal. Malpositioning and potential airway compromise occurs in more than half of placements. Vision-guided insertion can improve placement. In this article we propose the development of a 3rd generation supraglottic airway device, equipped with cameras and fiberoptic illumination, to visualise insertion of the device, enable immediate manoeuvres to optimise SAD position, verify whether correct 1st and 2nd seals are achieved and check whether size selected is appropriate. We do not provide technical details of such a ‘3rd generation’ device, but rather present a theoretical analysis of its desirable properties, which are essential to overcome the remaining limitations of current 1st and 2nd generation devices. We also recommend that this further milestone improvement, i.e. ability to place the SAD accurately under direct vision, be eligible for the moniker ‘3rd generation’. Blind insertion of SADs should become the exception and we anticipate, as in other domains such as central venous cannulation and nerve block insertions, vision-guided placement becoming the gold standard