47 research outputs found

    Portable light transmission measuring system for preserved corneas

    Get PDF
    BACKGROUND: The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. METHODS: The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. RESULTS: Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. CONCLUSION: By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively

    OSCA: a comprehensive open-access system of analysis of posterior capsular opacification

    Get PDF
    BACKGROUND: This paper presents and tests a comprehensive computerised system of analysis of digital images of posterior capsule opacification (PCO). It updates and expands significantly on a previous presentation to include facilities for selecting user defined central areas and for registering and subsequent merging of images for artefact removal. Also, the program is compiled and thus eliminates the need for specialised additional software. The system is referred to in this paper as the open-access systematic capsule assessment (OSCA). The system is designed to be evidence based, objective and openly available, improving on current systems of analysis. METHODS: Principal features of the OSCA system of analysis are discussed. Flash artefacts are automatically located in two PCO images and the images merged to produce a composite free from these artefacts. For this to be possible the second image has to be manipulated with a registration technique to bring it into alignment with the first. Further image processing and analysis steps use a location-sensitive entropy based texture analysis of PCO. Validity of measuring PCO progression of the whole new system is assessed along with visual significance of scores. Reliability of the system is assessed. RESULTS: Analysis of PCO by the system shows ability to detect early progression of PCO, as well as detection of more visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is demonstrated. CONCLUSION: This system of PCO analysis is evidence-based, objective and clinically useful. It incorporates flash detection and removal as well as location sensitive texture analysis. It provides features and benefits not previously available to most researchers or clinicians. Substantial evidence is provided for this system's validity and reliability

    A freely accessible, evidence based, objective system of analysis of posterior capsular opacification ; Evidence for its validity and reliability

    Get PDF
    BACKGROUND: The aim of this study was to develop a system of computerised analysis of digital images of posterior capsule opacification (PCO) that is evidence based, objective and freely available. The paper will present evidence for the reliability and validity of the developed system. METHODS: The system of PCO analysis was developed considering current published evidence on visual significance of PCO and additional investigative analysis of PCO images. Details of the image processing and analysis steps are discussed and a final system that measures an entropy score weighted toward proximity to central areas is described. In order to assess validity, the systems ability to measure PCO progression is assessed along with the visual significance of its final computerised scores. Reliability of the system is also assessed. RESULTS: The final system runs successfully and is simple to use. Analyses of PCO by the system show an ability to detect early progression of PCO as well as detection of visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is shown to be satisfactory. CONCLUSION: This paper presents a system of PCO analysis that is evidence based, objective and clinically useful. Substantial evidence is provided for its validity and reliability

    Marathon related death due to brainstem herniation in rehydration-related hyponatraemia: a case report

    Get PDF
    Introduction: Identifying marathon runners at risk of neurological deterioration at the end of the race (within a large cohort complaining of exhaustion, dehydration, nausea, headache, dizziness, etc.) is challenging. Here we report a case of rehydration-related hyponatraemia with ensuing brain herniation. Case presentation: We report the death of runner in his 30's who collapsed in the recovery area following a marathon. Following rehydration he developed a respiratory arrest in the emergency room. He was found to be hyponatraemic (130 mM). A CT brain scan showed severe hydrocephalus and brain stem herniation. Despite emergency insertion of an extraventricular drain, he was tested for brainstem death the following morning. Funduscopy demonstrated an acute-on-chronic papilledema; CSF spectrophotometry did not reveal any trace of oxyhemoglobin or bilirubin, but ferritin levels were considerably raised (530 ng/mL, upper reference value 12 ng/mL), consistent with a previous bleed. Retrospectively it emerged that the patient had suffered from a thunderclap headache some months earlier. Subsequently he developed morning headaches and nausea. This suggests that he may have suffered from a subarachnoid haemorrhage complicated by secondary hydrocephalus. This would explain why in this case the relatively mild rehydration-related hyponatremia may have caused brain swelling sufficient for herniation. Conclusion: Given the frequency of hyponatraemia in marathon runners (serum Na <135 mM in about 13%), and the non-specific symptoms, we discuss how a simple screening test such as funduscopy may help to identify those who require urgent neuroimaging

    Methods of assessment of patients for Nd:YAG laser capsulotomy that correlate with final visual improvement

    Get PDF
    BACKGROUND: This paper attempts to clarify the usefulness of various simple pre-operative measures in estimating the potential for a visually successful capsulotomy. METHODS: 24 patients attending for capsulotomy had pre-operative measures of glare with BAT tester, visibility of posterior pole and grading of posterior capsular pearls and fibrosis seen at slit lamp. Visual function was measured before and after standardised capsulotomy. Correlations of the various preoperative measures with eventual visual function improvements were calculated. RESULTS: Pearls at slit lamp and poor posterior pole visualisation were all correlated with improvements in visual acuity and contrast sensitivity after capsulotomy. Amount of fibrosis visible at slit lamp and glare assessment were not correlated with vision improvements after laser. CONCLUSION: Of the various measures that are taken prior to Nd : YAG capsulotomy, some correlate with eventual visual improvement but for others no clinical utility was found. Practitioners should note these findings as they are especially of use in more questionable or high-risk cases to help determine whether referral for PCO treatment by Nd: YAG capsulotomy is likely to benefit the patient

    Intravitreal triamcinolone for uveitic cystoid macular edema: An optical coherence tomography study

    No full text
    In this paper we outline an algorithmic approach to compute Puiseux series expansions for algebraic surfaces. The series expansions originate at the intersection of the surface with as many coordinate planes as the dimension of the surface. Our approach starts with a polyhedral method to compute cones of normal vectors to the Newton polytopes of the given polynomial system that defines the surface. If as many vectors in the cone as the dimension of the surface define an initial form system that has isolated solutions, then those vectors are potential tropisms for the initial term of the Puiseux series expansion. Our preliminary methods produce exact representations for solution sets of the cyclic nn-roots problem, for n=m2n = m^2, corresponding to a result of Backelin.Comment: accepted for presentation at ISSAC 201
    corecore