392 research outputs found

    Helicity at Photospheric and Chromospheric Heights

    Full text link
    In the solar atmosphere the twist parameter α\alpha has the same sign as magnetic helicity. It has been observed using photospheric vector magnetograms that negative/positive helicity is dominant in the northern/southern hemisphere of the Sun. Chromospheric features show dextral/sinistral dominance in the northern/southern hemisphere and sigmoids observed in X-rays also have a dominant sense of reverse-S/forward-S in the northern/southern hemisphere. It is of interest whether individual features have one-to-one correspondence in terms of helicity at different atmospheric heights. We use UBF \Halpha images from the Dunn Solar Telescope (DST) and other \Halpha data from Udaipur Solar Observatory and Big Bear Solar Observatory. Near-simultaneous vector magnetograms from the DST are used to establish one-to-one correspondence of helicity at photospheric and chromospheric heights. We plan to extend this investigation with more data including coronal intensities.Comment: 5 pages, 1 figure, 1 table To appear in "Magnetic Coupling between the Interior and the Atmosphere of the Sun", eds. S.S. Hasan and R.J. Rutten, Astrophysics and Space Science Proceedings, Springer-Verlag, Heidelberg, Berlin, 200

    Evaluation of the Performance of Routine Information System Management (PRISM) framework: evidence from Uganda

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sound policy, resource allocation and day-to-day management decisions in the health sector require timely information from routine health information systems (RHIS). In most low- and middle-income countries, the RHIS is viewed as being inadequate in providing quality data and continuous information that can be used to help improve health system performance. In addition, there is limited evidence on the effectiveness of RHIS strengthening interventions in improving data quality and use. The purpose of this study is to evaluate the usefulness of the newly developed Performance of Routine Information System Management (PRISM) framework, which consists of a conceptual framework and associated data collection and analysis tools to assess, design, strengthen and evaluate RHIS. The specific objectives of the study are: a) to assess the reliability and validity of the PRISM instruments and b) to assess the validity of the PRISM conceptual framework.</p> <p>Methods</p> <p>Facility- and worker-level data were collected from 110 health care facilities in twelve districts in Uganda in 2004 and 2007 using records reviews, structured interviews and self-administered questionnaires. The analysis procedures include Cronbach's alpha to assess internal consistency of selected instruments, test-retest analysis to assess the reliability and sensitivity of the instruments, and bivariate and multivariate statistical techniques to assess validity of the PRISM instruments and conceptual framework.</p> <p>Results</p> <p>Cronbach's alpha analysis suggests high reliability (0.7 or greater) for the indices measuring a promotion of a culture of information, RHIS tasks self-efficacy and motivation. The study results also suggest that a promotion of a culture of information influences RHIS tasks self-efficacy, RHIS tasks competence and motivation, and that self-efficacy and the presence of RHIS staff have a direct influence on the use of RHIS information, a key aspect of RHIS performance.</p> <p>Conclusions</p> <p>The study results provide some empirical support for the reliability and validity of the PRISM instruments and the validity of the PRISM conceptual framework, suggesting that the PRISM approach can be effectively used by RHIS policy makers and practitioners to assess the RHIS and evaluate RHIS strengthening interventions. However, additional studies with larger sample sizes are needed to further investigate the value of the PRISM instruments in exploring the linkages between RHIS data quality and use, and health systems performance.</p

    Loss of balancing selection in the βS globin locus

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Probably the best example of the rise and maintenance of balancing selection as an evolutionary trend is the role of S-haemoglobin (HbS - rs334) in protecting from malaria. Yet, the dynamics of such a process remains poorly understood, particularly in relation to different malaria transmission rates and the genetic background of the affected populations.</p> <p>Methods</p> <p>We investigated the association of haemoglobin HbS in protection from clinical episodes of malaria in two populations/villages where malaria is endemic, but mostly presenting in mild clinical forms. Five-hundred and forty-six individuals comprising 65 and 82 families from the Hausa and Massalit villages respectively were genotyped for HbS. Allele and genotype frequencies as well as departure from Hardy-Weinberg Equilibrium were estimated from four-hundred and seventy independent genotypes across different age groups. Age-group frequencies were used to calculate the coefficient-of-fitness and to simulate the expected frequencies in future generations.</p> <p>Results</p> <p>Genotype frequencies were within Hardy-Weinberg expectations in Hausa and Massalit in the total sample set but not within the different age groups. There was a trend for a decrease of the HbS allele frequency in Hausa and an increase of frequency in Massalit. Although the HbS allele was able to confer significant protection from the clinical episodes of malaria in the two populations, as suggested by the odds ratios, the overall relative fitness of the HbS allele seems to have declined in Hausa.</p> <p>Conclusions</p> <p>Such loss of balancing selection could be due to a combined effect of preponderance of non-clinical malaria in Hausa, and the deleterious effect of the homozygous HbS under circumstances of endogamy.</p

    Single Crystalline Cadmium Sulfide Nanowires with Branched Structure

    Get PDF
    In this article, we report the synthesis of branched single crystal CdS nanowires. This branched CdS nanostructure is prepared by a simple surfactant-directing method, which is of particular interest as it uses readily available reagents and provides a convenient route to high-yield single crystal nanowires but with branched shape. These branched nanowires have an average diameter of about 40 nm and length up to several micrometers. A possible mechanism has been proposed and the addition of surfactant dodecylthiol into the two mixed-solvents would play an importance effect on the structure of the product. Based on the mechanism, by controlling the synthesis conditions, such as the ratios between the surfactant, inorganic solvent, and organic solvent, other kinds of nanostructures based on CdS nanowires were also prepared. Photoluminescence (PL) measurement reveals that the branched CdS nanowires have a strong emission at about 700 nm which might be due to its special structure

    Suppression of Lung Tumorigenesis by Leucine Zipper/EF Hand–Containing Transmembrane-1

    Get PDF
    Leucine zipper/EF hand-containing transmembrane-1 (LETM1) encodes for the human homologue of yeast Mdm38p, which is a mitochondria-shaping protein of unclear function. However, a previous study demonstrated that LETM1 served as an anchor protein for complex formation between mitochondria and ribosome, and regulated mitochondrial biogenesis.Therefore, we examine the possibility that LETM1 may function to regulate mitochondria and lung tumor growth. In this study, we addressed this question by studying in the effect of adenovirus-mediated LETM1 in the lung cancer cell and lung cancer model mice. To investigate the effects of adenovirus-LETM1 in vitro, we infected with adenovirus-LETM1 in A549 cells. Additionally, in vivo effects of LETM1 were evaluated on K-ras(LA1) mice, human non-small cell lung cancer model mice, by delivering the LETM1 via aerosol through nose-only inhalation system. The effects of LETM1 on lung cancer growth and AMPK related signals were evaluated. Adenovirus-mediated overexpression of LETM1 could induce destruction of mitochondria of lung cancer cells through depleting ATP and AMPK activation. Furthermore, adenoviral-LETM1 also altered Akt signaling and inhibited the cell cycle while facilitating apoptosis. Theses results demonstrated that adenovirus-LETM1 suppressed lung cancer cell growth in vitro and in vivo.Adenovirus-mediated LETM1 may provide a useful target for designing lung tumor prevention and treatment

    Repeated growth and bubbling transfer of graphene with millimetre-size single-crystal grains using platinum

    Get PDF
    Large single-crystal graphene is highly desired and important for the applications of graphene in electronics, as grain boundaries between graphene grains markedly degrade its quality and properties. Here we report the growth of millimetre-sized hexagonal single-crystal graphene and graphene films joined from such grains on Pt by ambient-pressure chemical vapour deposition. We report a bubbling method to transfer these single graphene grains and graphene films to arbitrary substrate, which is nondestructive not only to graphene, but also to the Pt substrates. The Pt substrates can be repeatedly used for graphene growth. The graphene shows high crystal quality with the reported lowest wrinkle height of 0.8 nm and a carrier mobility of greater than 7,100 cm2 V−1 s−1 under ambient conditions. The repeatable growth of graphene with large single-crystal grains on Pt and its nondestructive transfer may enable various applications

    Quality of life and mortality from a nephrologist's view: a prospective observational study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although health-related quality of life (HRQOL) is a potential independent predictor of mortality, nephrologists have shown little interest in HRQOL with respect to mortality in chronic kidney disease (CKD). The aim of this article is to evaluate the impact of HRQOL on mortality in the elderly, who are likely to develop or already have CKD.</p> <p>Methods</p> <p>Among 1,000 randomly sampled participants aged more than 65 years (sourced from the Korean Longitudinal Study on Health and Ageing), 944 subjects were evaluated for HRQOL. HRQOL was assessed using a 36-item Short-Form health survey (SF36). A cumulative survival rate was calculated according to tertiles of SF36 scores and classified by the presence of CKD (estimated GFR <60 ml/min/1.73 m<sup>2</sup>).</p> <p>Results</p> <p>Among 944 subjects, 46.6% had CKD. CKD patients had lower total and physical component scores compared with subjects without CKD. The 3-year cumulative survival rate was 90.0% (non-CKD vs. CKD: 92.6% vs. 87.4%, <it>P </it>= 0.005 by log rank test). After adjusting for multiple variables, a reduced SF36 score (physical and mental components) was a strong predictor of all-cause mortality. Physical components were consistently able to predict mortality after CKD classification, but mental components were statistically significant only in the CKD group.</p> <p>Conclusion</p> <p>In addition to traditional risk factors of mortality, nephrologists should be aware of HRQOL as a predictor of mortality and should make efforts to improve HRQOL in CKD patients.</p

    Stretchable and wearable colorimetric patches based on thermoresponsive plasmonic microgels embedded in a hydrogel film

    Get PDF
    Stimuli-responsive colorimetric sensors are promising for various industrial and medical applications due to the capability of simple, fast, and inexpensive visualization of external stimuli. Here we demonstrate a thermoresponsive, smart colorimetric patch based on a thermoresponsive plasmonic microgel embedded in a stretchable hydrogel film. To achieve a fast and efficient thermoresponsive color change, raspberry-shaped plasmonic microgels were fabricated by decorating gold nanoparticles (AuNPs) on poly(N-isopropylacrylamide) (PNIPAM) microgels, which exhibit reversible and strain-insensitive color shifts (between red and grayish violet) in response to a temperature change. The smart colorimetric patch containing a plasmonic microgels exhibits a significant extinction peak shift (176 nm) in a short time (1 s), with a temperature-sensing resolution of 0.2 degrees C. Moreover, the transition temperature of the plasmonic microgel can be finely tuned by additives and comonomers, so that the exquisite temperature visualization can be conducted over a wide temperature range of 25-40 degrees C by assembling plasmonic microgel films with different transition temperatures into an array patch. For proof-of-concept demonstrations, a freestanding smart colorimetric patch was utilized as a spatial temperature scanner and a colorimetric thermometer for a thermoresponsive actuator, which is potentially applicable in smart, wearable sensors and soft robotics
    corecore