422 research outputs found

    Determination of APTT factor sensitivity - the misguiding guideline.

    Get PDF
    INTRODUCTION: The Clinical and Laboratory Standards Institute (CLSI) has produced a guideline detailing how to determine the activated partial thromboplastin time's (APTT) sensitivity to clotting factor deficiencies, by mixing normal and deficient plasmas. Using the guideline, we determined the factor sensitivity of two APTT reagents. METHODS: APTTs were performed using Actin FS and Actin FSL on a Sysmex CS-5100 analyser. The quality of factor-deficient and reference plasmas from three commercial sources was assessed by assaying each of the clotting factors within the plasmas and by performing thrombin generation tests (TGT). RESULTS: Testing samples from 50 normal healthy subjects gave a two-standard deviation range of 21.8-29.2 s for Actin FS and 23.5-29.3 s for Actin FSL. The upper limits of these ranges were subsequently used to determine APTT factor sensitivity. Assay of factor levels within the deficient plasmas demonstrated that they were specifically deficient in a single factor, with most other factors in the range 50-150 iu/dL (Technoclone factor VII-deficient plasma has 26 iu/dL factor IX). APTTs performed on mixtures of normal and deficient plasmas gave diverse sensitivity to factor deficiencies dependent on the sources of deficient plasma. TGT studies on the deficient plasmas revealed that the potential to generate thrombin was not solely associated with the levels of their component clotting factors. CONCLUSION: Determination of APTT factor sensitivity in accordance with the CLSI guideline can give inconsistent and misleading results

    The automation of routine light transmission platelet aggregation

    Get PDF
    Introduction: The investigation of platelet function by aggregometry requires specialist equipment and is labour intensive. We have developed an automated platelet aggregation method on a routine coagulation analyser. Methods: We used a CS-2000i (Sysmex) with prototype software to perform aggregation in platelet-rich plasma (PRP), using the following agonists: ADP (0.5-10 μm), epinephrine (0.5-10 μm), collagen (0.5-10 mg/μL), ristocetin (0.75-1.25 mg/mL) and arachidonic acid (0.12-1.0 mm). Platelet agonists were from Hyphen Biomed, and an AggRAM aggregometer (Helena Biosciences) was used as the reference instrument. Results: CS-2000i reaction cuvette stirrer speed was found to influence reaction sensitivity and was optimized to 800 rpm. There were no clinically significant changes in aggregation response when the PRP platelet count was 150-480 x 10/L, but below this there were changes in the maximum amplitude (MA) and slope (rate). Dose response with each of the agonists was comparable between CS-2000i and an AggRAM aggregometer and normal subjects receiving antiplatelet drugs. Aggregation imprecision was similar on both the CS-2000i and AggRAM systems, with a cv for 2-5 μm ADP MA and slope varying between 3-12%. Conclusion: Our preliminary studies indicated that optimal sensitivity using the CS-2000i was obtained with a reaction cuvette stirrer speed of 800 rpm and a PRP platelet count of 200-300 x 10/L; aggregation with a PRP count <100 x 10/L showed poor sensitivity. Imprecision and detection of antiplatelet drug effects was similar between the CS-2000i and AggRAM. These data demonstrate that CS-2000i is comparable to a stand-alone aggregometer, although CS-2000i has the advantages of walk-away technology and also required a smaller sample volume than the AggRAM (44% less). © 2013 John Wiley & Sons Ltd

    Lipidomic profiling of adipose tissue reveals an inflammatory signature in cancer-related and primary Lymphedema

    Get PDF
    © 2016 Sedger et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Cancer-related and primary lymphedema (LE) are associated with the production of adipose tissue (AT). Nothing is known, however, about the lipid-based molecules that comprise LE AT. We therefore analyzed lipid molecules in lipoaspirates and serum obtained from LE patients, and compared them to lipoaspirates from cosmetic surgery patients and healthy control cohort serum. LE patient serum analysis demonstrated that triglycerides, HDL- and LDL-cholesterol and lipid transport molecules remained within the normal range, with no alterations in individual fatty acids. The lipidomic analysis also identified 275 lipid-based molecules, including triacylglycerides, diacylglycerides, fatty acids and phospholipids in AT oil and fat. Although the majority of lipid molecules were present in a similar abundance in LE and non-LE samples, there were several small changes: increased C20:5-containing triacylglycerides, reduced C10:0 caprinic and C24:1 nervonic acids. LE AT oil also contained a signature of increased cyclopropane-type fatty acids and inflammatory mediators arachidonic acid and ceramides. Interestingly C20:5 and C22:6 omega-3-type lipids are increased in LE AT, correlating with LE years. Hence, LE AT has a normal lipid profile containing a signature of inflammation and omega-3-lipids. It remains unclear, however, whether these differences reflect a small-scale global metabolic disturbance or effects within localised inflammatory foci

    A performance evaluation of a novel human recombinant tissue factor prothrombin time reagent (Revohem (TM) PT)

    Get PDF
    Summary Introduction A new prothrombin time reagent (Revohem™ PT) based on recombinant human tissue factor produced by the silkworm-baculovirus expression system was tested. The aim of this study was to compare the performance of the new PT reagent with two widely used routine PT reagents. Methods All testing was performed on a Sysmex CS-5100 coagulometer. Revohem™ PT was tested for imprecision and stability using normal and abnormal lyophilized commercial control plasmas. Comparability was assessed with two widely used reagents: one containing recombinant human tissue factor (Reagent A) and the other a human placental thromboplastin (Reagent B) using a wide range of normal and abnormal plasmas and analyser-specific ISI values. Results Excellent between-day imprecision was obtained for Revohem™ PT (CV <1.0%) and acceptable open-vial on-board stability over 7 days. There was good agreement between methods in samples from patients with liver disease and patients receiving warfarin and no significant differences between methods with increasing INR values. Both recombinant reagents suffered less interference from lupus anticoagulant than the placental thromboplastin. Revohem™ PT had similar sensitivity to reagents A and B for FII, V, VII and X deficiency and demonstrated dose responsiveness to dabigatran, apixaban and rivaroxaban with steeper response curves than the comparison reagents. Conclusion Revohem™ PT showed comparable or improved performance relative to two widely used reagents and is suitable for use in warfarin control, detection of inherited factor II, V, VII and X deficiency and assessment of liver disease coagulopathy

    Use of the complement inhibitor Coversin to treat HSCT-associated TMA

    Get PDF
    Finding an inherited complement abnormality in HSCT-associated TMA provides a rationale for the use of a complement inhibitor.Alternative complement inhibitors such as Coversin should be considered in patients who are resistant to eculizumab

    Rivaroxaban versus warfarin to treat patients with thrombotic antiphospholipid syndrome, with or without systemic lupus erythematosus (RAPS): a randomised, controlled, open-label, phase 2/3, non-inferiority trial.

    Get PDF
    BACKGROUND: Rivaroxaban is established for the treatment and secondary prevention of venous thromboembolism, but whether it is useful in patients with antiphospholipid syndrome is uncertain. METHODS: This randomised, controlled, open-label, phase 2/3, non-inferiority trial, done in two UK hospitals, included patients with antiphospholipid syndrome who were taking warfarin for previous venous thromboembolism, with a target international normalised ratio of 2·5. Patients were randomly assigned 1:1 to continue with warfarin or receive 20 mg oral rivaroxaban daily. Randomisation was done centrally, stratified by centre and patient type (with vs without systemic lupus erythematosus). The primary outcome was percentage change in endogenous thrombin potential (ETP) from randomisation to day 42, with non-inferiority set at less than 20% difference from warfarin in mean percentage change. Analysis was by modified intention to treat. Other thrombin generation parameters, thrombosis, and bleeding were also assessed. Treatment effect was measured as the ratio of rivaroxaban to warfarin for thrombin generation. This trial is registered with the ISRCTN registry, number ISRCTN68222801. FINDINGS: Of 116 patients randomised between June 5, 2013, and Nov 11, 2014, 54 who received rivaroxaban and 56 who received warfarin were assessed. At day 42, ETP was higher in the rivaroxaban than in the warfarin group (geometric mean 1086 nmol/L per min, 95% CI 957-1233 vs 548, 484-621, treatment effect 2·0, 95% CI 1·7-2·4, p<0·0001). Peak thrombin generation was lower in the rivaroxaban group (56 nmol/L, 95% CI 47-66 vs 86 nmol/L, 72-102, treatment effect 0·6, 95% CI 0·5-0·8, p=0·0006). No thrombosis or major bleeding were seen. Serious adverse events occurred in four patients in each group. INTERPRETATION: ETP for rivaroxaban did not reach the non-inferiority threshold, but as there was no increase in thrombotic risk compared with standard-intensity warfarin, this drug could be an effective and safe alternative in patients with antiphospholipid syndrome and previous venous thromboembolism

    Rivaroxaban limits complement activation compared with warfarin in antiphospholipid syndrome patients with venous thromboembolism

    Get PDF
    Background: Complement activation may play a major role in the pathogenesis of thrombotic antiphospholipid syndrome (APS). Coagulation proteases such as factor Xa can activate complement proteins. Aims: To establish whether rivaroxaban, a direct factor Xa inhibitor, limits complement activation compared to warfarin in APS patients with previous venous thromboembolism (VTE). Methods: 111 APS patients with previous VTE, on warfarin target INR 2.5, had blood samples taken at baseline and at day 42 after randomisation in the RAPS (Rivaroxaban in Antiphospholipid Syndrome) trial. Fifty-six patients remained on warfarin and 55 switched to rivaroxaban. Fifty-five normal controls (NC) were also studied. Markers of complement activation (C3a, C5a, terminal complement complex (SC5b-9) and Bb fragment), were assessed. Results APS patients had significantly higher complement activation markers compared to NC at both time points irrespective of the anticoagulant. There were no differences between the two patient groups at baseline, or patients remaining on warfarin at day 42. In 55 patients randomised to rivaroxaban, C3a, C5a and SC5b-9 were significantly lower at day 42; median (ng/mL) [confidence interval] 64 [29-125] vs 83 [35-147], 9 [2–15] vs 12 [4 -18] and 171 [56-245] vs 201 [66-350] respectively, but levels of Bb were unchanged. There were no correlations between rivaroxaban levels and complement activation markers. Conclusions: APS patients with previous VTE on warfarin exhibit significantly increased complement activation, which is likely to occur via the classical pathway, and is decreased by rivaroxaban administration. Rivaroxaban may therefore potentially provide benefit additional to its anticoagulant effect in this patient group by limiting complement activation
    corecore