51 research outputs found
A prolonged run-in period of standard subcutaneous microdialysis ameliorates quality of interstitial glucose signal in patients after major cardiac surgery
We evaluated a standard subcutaneous microdialysis technique for glucose monitoring in two critically ill patient populations and tested whether a prolonged run-in period improves the quality of the interstitial glucose signal. 20 surgical patients after major cardiac surgery (APACHE II score: 10.1 ± 3.2) and 10 medical patients with severe sepsis (APACHE II score: 31.1 ± 4.3) were included in this investigation. A microdialysis catheter was inserted in the subcutaneous adipose tissue of the abdominal region. Interstitial fluid and arterial blood were sampled in hourly intervals to analyse glucose concentrations. Subcutaneous adipose tissue glucose was prospectively calibrated to reference arterial blood either at hour 1 or at hour 6. Median absolute relative difference of glucose (MARD), calibrated at hour 6 (6.2 (2.6; 12.4) %) versus hour 1 (9.9 (4.2; 17.9) %) after catheter insertion indicated a significant improvement in signal quality in patients after major cardiac surgery (p < 0.001). Prolonged run-in period revealed no significant improvement in patients with severe sepsis, but the number of extreme deviations from the blood plasma values could be reduced. Improved concurrence of glucose readings via a 6-hour run-in period could only be achieved in patients after major cardiac surgery
Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit.
BACKGROUND: Continuous Glucose Monitoring (CGM) has become an increasingly investigated tool, especially with regards to monitoring of diabetic and critical care patients. The continuous glucose data allows the calculation of several glucose variability parameters, however, without specific application the interpretation of the results is time-consuming, utilizing extreme efforts. Our aim was to create an open access software [Glycemic Variability Analyzer Program (GVAP)], readily available to calculate the most common parameters of the glucose variability and to test its usability. METHODS: The GVAP was developed in MATLAB(R) 2010b environment. The calculated parameters were the following: average area above/below the target range (Avg. AUC-H/L); Percentage Spent Above/Below the Target Range (PATR/PBTR); Continuous Overall Net Glycemic Action (CONGA); Mean of Daily Differences (MODD); Mean Amplitude of Glycemic Excursions (MAGE). For verification purposes we selected 14 CGM curves of pediatric critical care patients. Medtronic(R) Guardian(R) Real-Time with Enlite(R) sensor was used. The reference values were obtained from Medtronic(R)'s own software for Avg. AUC-H/L and PATR/PBTR, from GlyCulator for MODD and CONGA, and using manual calculation for MAGE. RESULTS: The Pearson and Spearman correlation coefficients were above 0.99 for all parameters. The initial execution took 30 minutes, for further analysis with the Windows(R) Standalone Application approximately 1 minute was needed. CONCLUSIONS: The GVAP is a reliable open access program for analyzing different glycemic variability parameters, hence it could be a useful tool for the study of glycemic control among critically ill patients
Control of Glycogen Content in Retina: Allosteric Regulation of Glycogen Synthase
Retinal tissue is exceptional because it shows a high level of energy metabolism. Glycogen content represents the only energy reserve in retina, but its levels are limited. Therefore, elucidation of the mechanisms controlling glycogen content in retina will allow us to understand retina response under local energy demands that can occur under normal and pathological conditions. Thus, we studied retina glycogen levels under different experimental conditions and correlated them with glucose-6-phosphate (G-6-P) content and glycogen synthase (GS) activity
Recommended from our members
Fetal and postnatal outcomes in offspring after intrauterine metformin exposure: A systematic review and meta-analysis of animal experiments.
Publication status: PublishedFunder: ZonMw; doi: http://dx.doi.org/10.13039/501100001826BACKGROUND: The impact of maternal metformin use during pregnancy on fetal, infant, childhood and adolescent growth, development and health remains unclear. OBJECTIVES: Our objective was to systematically review the available evidence from animal experiments on the effects of intrauterine metformin exposure on offspring's anthropometric, cardiovascular and metabolic outcomes. METHODS: A systematic search was conducted in Pubmed and Embase from inception (searched on 12th April 2023). We extracted original, controlled animal studies that investigated the effects of maternal metformin use during pregnancy on offspring anthropometric, cardiovascular and metabolic measurements. Subsequently, risk of bias was assessed and meta-analyses using the standardized mean difference and a random effects model were conducted for all outcomes containing data from 3 or more studies. Subgroup analyses were planned for species, strain, sex and type of model in case of 10 comparisons or more per subgroup. RESULTS: We included 37 articles (n= 3133 offspring from n=716 litters, containing n= 51 comparisons) in this review, mostly (95%) on rodent models and 6% pig models. Follow-up of offspring ranged from birth to two years of age. Thirty four of the included articles could be included in the meta-analysis. No significant effects in the overall meta-analysis of metformin on any of the anthropometric, cardiovascular and metabolic offspring outcome measures were identified. Between studies heterogeneity was high, and risk of bias was unclear in most studies as a consequence of poor reporting of essential methodological details. CONCLUSION: This systematic review was unable to establish effects of metformin treatment during pregnancy on anthropometric, cardiovascular and metabolic outcomes in non-human offspring. Heterogeneity between studies was high and reporting of methodological details often limited. This highlights a need for additional high quality research both in humans and model systems to allow firm conclusions to be established. Future research should include focus on the effects of metformin in older offspring age groups, and on outcomes which have gone uninvestigated to date
- …