8,670 research outputs found

    Rectal Hyposensitivity

    Get PDF

    PIN17 THE COST-EFFECTIVENESS OF A MENINGOCOCCAL SEROGROUP C CONJUGATE VACCINE IN GERMANY

    Get PDF

    Simultaneous Colonic Pressure Waves in Children and Young Adults with Gastrointestinal Motility Disorders: Artefact or Colonic Physiology?

    Get PDF
    BACKGROUND: Simultaneous pressure waves (SPW) spanning all recording sites in colonic manometry studies have been described as a potential biomarker of normal gas transit and extrinsic neural reflexes. In pediatric studies utilizing combined antroduodenal and colonic manometry, it was noted that most colonic SPWs appeared to also span all sensors in the gastric and small bowel regions. This suggests that a proportion of colonic SPWs may represent an artefact caused by forces extrinsic to the colon. Our aim was to characterize colonic SPWs and determine how many of these spanned most of the digestive tract. METHODS: In 39 combined high-resolution antroduodenal and colonic manometry traces from 27 pediatric patients, we used our purpose-built software to identify all SPWs that spanned either (i) all recording sites in the digestive tract or (ii) those restricted to the colon. RESULTS: A total of 14,565 SPWs were identified (364 ± 316 SPWs/study), with 14,550 (99.9%) spanning the entire antroduodenal and colonic recording sites. Only 15 SPWs (0.1% of the total) were restricted to the colon (all in one recording). CONCLUSIONS: Based on these findings, we suggest that, in pediatric studies, SPWs should not form part of any diagnostic criteria, as these events appear to be an artefact caused by factors outside the colon (abdominal strain, body motion)

    Gastrointestinal Transit Times in Health as Determined Using Ingestible Capsule Systems: A Systematic Review.

    Get PDF
    BACKGROUND: Ingestible capsule (IC) systems can assess gastrointestinal (GI) transit times as a surrogate for gut motility for extended periods of time within a minimally invasive, radiation-free and ambulatory setting. METHODS: A literature review of IC systems and a systematic review of studies utilizing IC systems to measure GI transit times in healthy volunteers was performed. Screening for eligible studies, data extraction and bias assessments was performed by two reviewers. A narrative synthesis of the results was performed. RESULTS: The literature review identified 23 different IC systems. The systematic review found 6892 records, of which 22 studies were eligible. GI transit time data were available from a total of 1885 healthy volunteers. Overall, seventeen included studies reported gastric emptying time (GET) and small intestinal transit time (SITT). Colonic transit time (CTT) was reported in nine studies and whole gut transit time (WGTT) was reported in eleven studies. GI transit times in the included studies ranged between 0.4 and 15.3 h for GET, 3.3-7 h for SITT, 15.9-28.9 h for CTT and 23.0-37.4 h for WGTT. GI transit times, notably GET, were influenced by the study protocol. CONCLUSIONS: This review provides an up-to-date overview of IC systems and reference ranges for GI transit times. It also highlights the need to standardise protocols to differentiate between normal and pathological function

    Limitations for change detection in multiple Gabor targets

    Get PDF
    We investigate the limitations on the ability to detect when a target has changed, using Gabor targets as simple quantifiable stimuli. Using a partial report technique to equalise response variables, we show that the log of the Weber fraction for detecting a spatial frequency change is proportional to the log of the number of targets, with a set-size effect that is greater than that reported for visual search. This is not a simple perceptual limitation, because pre-cueing a single target out of four restores performance to the level found when only one target is present. It is argued that the primary limitation on performance is the division of attention across multiple targets, rather than decay within visual memory. However in a simplified change detection experiment without cueing, where only one target of the set changed, not only was the set size effect still larger, but it was greater at 2000 msec ISI than at 250 msec ISI, indicating a possible memory component. The steepness of the set size effects obtained suggests that even moderate complexity of a stimulus in terms of number of component objects can overload attentional processes, suggesting a possible low-level mechanism for change blindness

    Gastrointestinal motility during sleep assessed by tracking of telemetric capsules combined with polysomnography - a pilot study.

    Get PDF
    Studies of gastrointestinal function during sleep are hampered by lack of applicable techniques. Recent development of a novel ambulatory telemetric capsule system, which can be used in conjunction with polysomnography, offers a solution to this problem. The 3D-Transit system consists of ingestible electromagnetic capsules traceable through a portable extracorporeal receiver while traversing the gut. During sleep monitored by polysomnography, gastrointestinal motility was concurrently investigated using 3D-Transit in nine healthy subjects. Overall, the amplitude of gastric contractions decreased with depth of sleep (light sleep, N2 versus deep sleep, N3; P<0.05). Progression through the small intestine did not change with depth of sleep (Kruskal-Wallis probability =0.1), and there was no association between nocturnal awakenings or arousals and the occurrence of colonic or small intestinal propagating movements. Basal colonic activity was suppressed during both deep sleep (P<0.05) and light sleep (P<0.05) when compared with nocturnal wake periods. In conclusion, the novel ambulatory 3D-Transit system combined with polysomnography allows minimally invasive and completely ambulatory investigation of associations between sleep patterns and gastrointestinal motility

    Albumin concentrations are primarily determined by the body cell mass and the systemic inflammatory response in cancer patients with weight loss

    Get PDF
    The association between hypoalbuminemia and poor prognosis in patients with cancer is well recognized. However, the factors that contribute to the fall in albumin concentrations are not well understood. In the present study, we examined the relationship between circulating albumin concentrations, weight loss, the body cell mass (measured using total body potassium), and the presence of an inflammatory response (measured using C- reactive protein) in male patients (n=40) with advanced lung or gastrointestinal cancer. Albumin concentrations were significantly correlated with the percent ideal body weight (r=0.390, p lt 0.05), extent of reported weight loss (r=-0.492, p lt 0.01), percent predicted total body potassium (adjusted for age, height, and weight, r=0.686, p lt 0.001), and logo C-reactive protein concentrations (r=-0.545, p lt 0.001). On multiple regression analysis, the percent predicted total body potassium and log(10) C-reactive protein concentrations accounted for 63% of the variation in albumin concentrations (r(2) = 0.626, p lt 0.001). The interrelationship between albumin, body cell mass, and the inflammatory response is consistent with the concept that the presence of an ongoing inflammatory response contributes to the progressive loss of these vital protein components of the body and the subsequent death of patients with advanced cancer

    Evaluating the risk factors for the development of benign disorders of defaecation: a surgical perspective.

    Get PDF
    PURPOSE: There remains uncertainty as to which risk factors are important for the development of defaecatory problems as a result of heterogeneity of published evidence. Understanding the impact of risk factors may be important in selecting targets for disease prevention or reversal. The aim of this study was to identify and evaluate risk factors for faecal incontinence and chronic constipation. METHODS: Risk factors for chronic constipation and faecal incontinence were long-listed from scientific literature, then anonymously evaluated (by 50 predominantly colorectal surgical experts from the UK Pelvic Floor Society) using a Delphi technique. Each risk factor was rated as independent, a co-factor, or not a risk factor. Independent risk factors were rated between 1 (not important) and 10 (critically important) with mean (± standard deviation) calculated. RESULTS: Thirty-eight risk factors for chronic constipation were evaluated. Eighteen were classed as independent and 16 as co-factors. Opioid analgesia (7.87 ± 2.05), eating disorders (7.80 ± 1.72), and history of abuse (7.70 ± 1.89) were scored as most important independent risk factors. Female sex (6.60 ± 2.02) was considered an independent risk factor but increasing age was rated a co-factor. Thirty-three risk factors for faecal incontinence were evaluated. Twenty were classed as independent and eight as co-factors. Third- or fourth-degree tear (8.88 ± 1.57), instrumental delivery (8.47 ± 1.58), and grand multiparity (8.00 ± 1.63) were rated most important. Increasing age (7.41 ± 2.14) and female sex (7.58 ± 2.05) were both considered independent risk factors. CONCLUSIONS: Several risk factors for chronic constipation and faecal incontinence were selected by Delphi approach. These factors will feed forward into Bayesian models of disease prediction that combine data and expert knowledge
    • …
    corecore