17 research outputs found

    Risk-adjusted outcome analysis of endovascular abdominal aortic aneurysm repair in a large population: how do stent-grafts compare?

    Get PDF
    Contains fulltext : 48510.pdf (publisher's version ) (Open Access)PURPOSE: To compare differences in the applicability and incidence of postoperative adverse events among stent-grafts used for repair of infrarenal aortic aneurysms. METHODS: An analysis of 6787 patients from the EUROSTAR Registry database was conducted to compare aneurysm morphological features, patient characteristics, and postoperative events for the AneuRx, EVT/Ancure, Excluder, Stentor, Talent, and Zenith devices versus the Vanguard device (control) and each other. Annual incidence rates of complications were determined, and risks were compared using the Cox proportional hazards analysis. RESULTS: The annual incidence rates were: device-related endoleak (types I and III) 6% (range 4%-10%), type II endoleak 5% (range 0.3%-11%), migration 3% (range 0.5%-5%), kinking 2% (range 1%-5%), occlusion 3% (range 1%-5%), rupture 0.5% (range 0%-1%), and all-cause mortality 7% (range 5%-8%). After adjustment for factors influencing outcome, AneuRx, Excluder, Talent, and Zenith devices were associated with a lower risk of migration, kinking, occlusion, and secondary intervention compared to the Vanguard device. Significant increased risk for conversion (EVT/Ancure) and reduced risk of aneurysm rupture (AneuRx and Zenith) and all-cause mortality (Excluder) were found compared to the Vanguard device. CONCLUSIONS: Significant differences exist between stent-grafts of different labels in terms of applicability and complications during intermediate to long-term follow-up. Since each stent-graft has its drawbacks, no single label can be identified as the best. It is reassuring that developments in stent-grafts indeed result in better performance than the early stent-grafts. However, a single device incorporating all the perceived improvements should still be pursued

    Rupture of infra-renal aortic aneurysm after endovascular repair: a series from EUROSTAR registry.

    No full text
    Contains fulltext : 139902.pdf (publisher's version ) (Closed access)OBJECTIVES: Although small, the risk of rupture after EVAR remains a major concern. The aim of this study was to identify mechanisms of late aneurysm rupture after endovascular repair. METHODS: Patients who suffered a proven aneurysm rupture after EVAR were identified from the EUROSTAR (European Collaborators on Stent-graft Techniques for Abdominal Aortic Aneurysm Repair) registry. Complications preceding rupture were studied to identify common patterns and possible mechanisms of late rupture. RESULTS: A rupture was documented in 34 patients resulting in death of 21 (62%). Adverse events documented during previous follow-up in these patients included endoleak (30%), migration (18%), limb occlusion (12%) and kinking (12%). The findings at time of rupture were documented in 24 patients and including endoleak: Type III (10), Type I (9), Type II (1); stent-graft disintegration (2) and migration (3). Aneurysm diameter changes could be ascertained in 24 patients and had increased in only seven. CONCLUSION: The importance of graft-related endoleak, stent-graft disintegration and migration in the causation of aneurysm rupture was confirmed. Poor compliance with follow-up schedule was also identified as a common feature. However, the absence of complications in some patients, who attended regularly for follow-up, highlights the difficulty of predicting rupture after EVAR
    corecore